background image

A

Product

Ion Dome

Test conducted at Bio care Research India Pvt Ltd

Sr. No.

Time (min)

SARS-CoV-2

E Gene

S Gene

Ct Value

Delta Ct

%Reduction 

in Viral Load

Ct Value

Delta Ct

%Reduction 

in Viral Load

1

0

23

-

-

21

-

-

2

10

24

1

-

22

1

-

3

15

27

3

10

25

3

10

4

30

32

5

60

30

5

60

5

60

ND

-

99.99

ND

-

99.99

Содержание Ion Dome

Страница 1: ...A Product Ion Dome An Ionizer for CleanAir A Product ...

Страница 2: ...A Product Ion Dome A Product We are BüRGE Brief Intro of BüRGE ...

Страница 3: ...A Product Ion Dome Our Vision Our Mission Vision Mission ...

Страница 4: ...A Product Ion Dome BüRGE s Innovative Technology About BüRGE Innovation ...

Страница 5: ...ectronic circuit fine electrodes The ionsform OH radicals and withdraws H Hydrogen from surface proteinof microorganisms breaking them down Effectively neutralizes viruses and bacteria and fungi No Ozone Generation Naturally cleans theair Generateswater as aby product ...

Страница 6: ...s OH H O H2O virus Ion Dome is an Enclosed High Voltage ION generator It generates Millions of ions H 0 like nature by breaking water molecules in air These ions get attracted attached to suspended impurities microorganisms in the room like Viruses Bacteria Fungi and Neutralizes them while generating water molecules as a byproduct H ...

Страница 7: ... and Neutralizes them while generating molecules as a by product Decrease odor and smoke Bring Freshness in the Air 99 9 Clean Air Suitable for Bedroom Office Store Clinic Auto Shut off with Timer function 3 hours Simple start with single push button Power on indication No ozone generation Available in Two Different Colors ...

Страница 8: ...51 5 75 Rated Power W 10W 10W Recommended Room Size Air circulation 150 sq ft Bedroom 200 sq ft Living Room Operating Temperature 0 C to 45 C Humidity 40 to 75 Cord Length mm 1830 Negative Ion Count 10 Million Dimensions L B H mm 95 135 130 Weight gm 800 Warranty 1Year Removes Impurities microorganisms in the room like Viruses Bacteria Fungi and Neutralizes them while generating molecules as a by ...

Страница 9: ...er above points Let it dry thoroughly before storing Store the appliance in a cool dry location Ion Dome is an Enclosed High Voltage ION generator It generates Millions of ions H 0 like nature by breaking water molecules in air These ions get attract attached to suspended impurities microorganism in the room like viruses Bacteria Fungi and Neutralizes them while generating watermolecules as a bypr...

Страница 10: ...nd INSTALLATION GUIDELINE When using the unit place at least 2 meters away from equipment utilizing electric waves such as television or radios to avoid electrical interference Avoid use in locations where furniture fabrics or other item may come in contact with and restrict the air intake and or air outlet Avoid use in locations where the unit is exposed to condensation or drastic temperature cha...

Страница 11: ...A Product Ion Dome Front View Side View ON OFF Push Button LED Indication Input Jack Product Overview ...

Страница 12: ...on top of the appliance Don t insert your fingers or foreign objects into the air outlet inlet to prevent physical injury or malfunction of appliance Don t use this appliance when you have used indoor smoke type insect repellents or in place with oily residues burning incense or chemical fumes Don t use the appliance near gas appliances heating device or fireplaces Don t use appliance in wet surro...

Страница 13: ...2 2 MS2 Phage Test parameters Initial Log pfu Exposure Duration in hour After exposure Log pfu Percent Reduction MS 2 Virus 3 851 7100 pfu 1 3 194 1564 pfu 77 9 2 3 089 1230 pfu 82 6 3 2 778 601 pfu 91 5 Formaldehyde Test parameters Initial Level mg m3 Exposure Duration in hour After exposure Formaldehyde Level mg m3 Percent Reduction Formaldehyde 0 32 1 0 189 40 9 2 0 183 42 8 3 0 175 45 3 Third ...

Страница 14: ... 0 5pp m Below detectabl e limit 01 0 5ppm 02 0 5ppm 03 0 5ppm Product Test Parameter Initial Log cfu Exposure Duration In hour After Exposure Log cfu Log Reduction after exposure to Test Material Percent Reduction DC ionizer Model IONGNR008 003 A Niger 4 919 83000 cfu 01 4 342 22000 cfu 0 58 73 4 02 3 845 7000 cfu 1 07 91 5 03 3 255 1800 cfu 1 66 97 8 ...

Страница 15: ... care Research India Pvt Ltd Sr No Time min SARS CoV 2 E Gene S Gene Ct Value Delta Ct Reduction in Viral Load Ct Value Delta Ct Reduction in Viral Load 1 0 23 21 2 10 24 1 22 1 3 15 27 3 10 25 3 10 4 30 32 5 60 30 5 60 5 60 ND 99 99 ND 99 99 ...

Страница 16: ...A Product Ion Dome Contact Us Plot No AL 18 AL 19 MIDC Shendra SEZArea Aurangabad MH431001 India 917875448466 rajendrathombre dhoottransmission com ...

Отзывы: