Burg B-Smart-Lock Скачать руководство пользователя страница 3

B-Smart-Lock Keypad | April 2015

  English | 3

Technical Data

Inner housing  
dimensions

60 x 60 x 22 mm

Keypad  
dimensions  

58.2 x 58.2 x 6.5 mm

Battery 

Lithium battery 3 V, CR123A

Service life 30,000 locking 
cycles

Permiss. temperature 

0°C – 40°C  (no  formation   
of condensation)

Code length

4 or 6

Programming 

Private mode (permanent 
code) and multi user  
(hotel mode)

Material

Keypad material: Zamak
Lock housing: Plastic

Locking  
direction 

R/L and LaD

Lock fastening

4 screws

Programming

 Setting Private Mode

Enter Master Code

√√

 1 MasterCode 

 

Select Private Mode

√√

 5 0 

   

Enter Master Code

√√

 1 Master Code 

 

Set Private PIN

√√

 3 Private PIN (6-digit) 

Setting your private PIN

Enter Master Code

√√

 1 Master Code 

 

Set Private PIN

√√

 3 Private PIN (6-digit) 

50 PINs are possible.

Multi User change from 4 to 6-digit and vice versa

Enter Master Code

√√

 1 Master Code 

 

Determine  
number of digits

√√

 0 x 

 (x = 4 or 6) 

If you have forgotten the Multi User Code,  
put the lock back into Private Mode.  
You can subsequently change back into 
Multi User Mode.

Change from Private to Multi User

Enter Master Code

√√

 1 Master Code 

 

Select Private Mode

√√

 5 1 

 

Enter Master Code

√√

 1 Master Code 

 

Determine  
number of digits

√√

 0 x 

 (x=4 or 6) 

Necessitate use of Verification Code Entry in  
Multi User Mode 

EnterMaster Code

√√

 1 Master Code 

 

Activate Verification 
Entry

√√

 2 1 

   

In order to remove the verification entry again,  
press 1 instead of 0 in step two.

Turn off / on Lock Mode

EnterMaster Code

√√

 1 Master Code 

 

Turn off Lock Mode

√√

 6 1 

 

In order to turn lock mode back on,  
press 1 instead of 0 in step two. 

Set Individual Master Code

EnterMaster Code

√√

 1 Master Code 

 

Enter new Master Code

√√

 7 new Master Code 

 

The Master Code must have 6 digits. 

Turn on / off Status Display

EnterMaster Code

√√

 1 Master Code 

 

Turn on Status Display

√√

 8 1 

 

In order to turn off status display,  
press 1 instead of 0 in step two. 

Delete Private PINs   

EnterMaster Code

√√

 1 Master Code 

 

Delete Code

√√

 9 xxxxxx  

(Code to be deleted) 

 

The code is deleted. 

-SMART-LOCK