Instructions for use
With the
secuENTRY pro 7071 RELAY
you have the chance to
control electric devices. In order for this to work, the controlling
device needs to be connected with the
secuENTRY pro 7071 RELAY
.
The
secuENTRY pro 7071 RELAY
can be operated via the keypads
secuENTRY Keypad PIN and secuENTRY Keypad FS or with the
respective App for your Smartphone*.
For the needed energisation, you need a separate mains adapter with
a voltage range between 6V and 12V direct current voltage.
Attention! The mains adapter is not included within the
delivery scope.
Following connectors are available:
– + 6V - +12V
– -GND
– COM
– NC breaker (max. 24V, 2A)
– NO maker (max. 24V, 2A)
Important
: Assembly and installation can only be performed by a
technician or another specialist.
With damage due to wrong installation the warranty claim expires.
Please read the instruction manual carefully before installation and
commissioning your device/devices and store it away safely.
The
secuENTRY pro 7071 RELAY
is not prepared for the assembly
in an outside area. We therefore advise an installation in a weather
protected area in order to guarantee a safe usage.
A voltage of 230V must not be switched over the relay! (max. 24V)
The mains adapter is plugged via the +/- connectors.
Between COM and NC lies the potential-free breaker resp. between
COM and NO the potential-free maker.
Maximum switching time: 17 hrs. 59 min. 59. Sec.
* Please check at:
www.burg.biz/secuentry/description
if your smartphone is compatible with the App.
Radio range
The radio range in free field is up to 4 meters. The range depends on
the surrounding and therefore can vary strongly.
Before screwing/sticking on the
secuENTRY pro 7071 RELAY
device,
please perform a test to make sure that radio reception for the
secuEN-
TRY pro 7071 RELAY
is guaranteed at the chosen location.
If the
secuENTRY pro 7071 RELAY
does not have radio reception (the
device does not switch), choose another 10 cm shifted location and try
again.
This process has to be repeated until radio contact exists. You can fix the
secuENTRY pro 7071 RELAY with either the adhesive-pad or with screws
(exclusive).
Screw positions are above the circuit board. Tuck firm the cables at the
given clamping position (clamping inscription is inside the cover) and
initiate electric supply. Afterwards, screw on the cover to the baseplate.
Administratorcode / QR-Code
Enclosed with every
secuENTRY pro 7071 RELAY
there is a QR-code
including an administrator-code. This QR-Code is required for setting
up the switching possibilities via the BURG-WÄCHTER KeyApp as
well as for logging in and introducing the keypad or the secuENTRY
software.
Important:
Before you assemble the secuENTRY pro 7071 RELAY,
you should change the existing administrator-code (factory setting:
123456) via the PC software or the keypad.
Attention! With a loss of the administrator- and/or the QR code
the reprogramming resp. the use of all administrator functions
is not possible anymore. Please store away safely!
Tip: The QR-code can also be scanned in electronic form as a file
or saved as a photo onto a protected data carrier.
Commissioning
The
secuENTRY pro 7071 RELAY
functions as an evaluation unit that
is integrated into your locking environment via the PC software or a
secuENTRY keypad. Additionally, access-authorised resp. switching-
entitled users, as well as active periods of the
secuENTRY pro 7071
RELAY
over the switch clock, can be set up.
Electronic Door Lock
secuENTRY pro 7071 RELAY
Download: www.burg.biz
Download: www.burg.biz
Download: www.burg.biz
Download: www.burg.biz
Descarga: www.burg.biz
Download: www.burg.biz
Download: www.burg.biz
Download: www.burg.biz
Download: www.burg.biz
Ladattava tiedosto: www.burg.biz
λήψη: www.burg.biz
İndir: www.burg.biz
Descărcare: www.burg.biz
Pobieranie pliku: www.burg.biz
Stáhnout: www.burg.biz
Letölthető: www.burg.biz
Download: www.burg.biz
Download: www.burg.biz
Download: www.burg.biz
загрузка: www.burg.biz
Download (зареди): www.burg.biz
Download: www.burg.biz
BW_Relay_BA_sE_012111
SWI 260320
This instruction manual demonstrates only the procedure for
incorporating the
secuENTRY pro 7071 RELAY
, learn more details from
the instructions for the PC software resp. the secuENTRY keypads.
Instructing the secuENTRY pro 7071 RELAY via the software
• Under lock management, add a new lock to the setting menu.
The screen window for lock configuration appears.
Ill.1: Manual lock configuration
• Lock name
Assign a freely chosen lock name. This lock name will reappear in the
lock allocation.
• Standard options
Enclosed to every
secuENTRY pro 7071 RELAY
is a QR code that
includes all necessary information. The most easy and convenient way for
initiation is to scan this QR code. Proceed as follows:
– Connect a webcam and click “scan QR code”
– Hold the code in a way the cam can capture it
Please note that the QR code of the Cylinder includes the following
information: (SN, MAC, AES and ADM)
BURG-WÄCHTER KG
·
Altenhofer Weg 15
·
58300 Wetter
·
Germany
·
www.burg.biz
English I 1