5.4 Changing Machine Setpoints, cont’d.
5.4.4 Melt Rack Alarm Setpoints
1. From the “MAIN MENU” screen, touch “MELT
RACK ALARM SETPOINTS”.
2. The following pop-up screen will appear.
3. This setting determines at what temperature
the alarm will sound indicating the maximum
desired temperature for the melt rack(s) have
been reached. Once the desired adjustments
have been entered touch the “CLOSE” box to
return to the previous screen.
5.4.5 Rail
Override
1. From the “MAIN MENU” screen, touch “RAIL
OVERRIDE”.
2. The following pop-up screen will appear.
3. When “enabled” the rail number displayed in
the box below “set rail” overrides all other
spray rails. Useful in the event of rail
recognition sensor failure. Once the desired
adjustments have been entered touch the
“CLOSE” box to return to the previous
screen.
5.4.6 Mix Tank Alarm Setpoints
1. From the “MAIN MENU” screen, touch “MIX
TANK ALARM SETPOINTS”.
2. The following pop-up screen will appear.
3. This setting determines at what temperature
the alarm will sound indicating the maximum
(range: 0 – 150) or minimum (range: 0 – 80)
desired temperature for the mix tank has
been reached. Also sets the tank level
(range: 0 – 100) at which the alarm will sound
to prevent the mix tank from being overfilled.
Once the desired adjustments have been
entered touch the “CLOSE” box to return to the previous screen.