7
After use
Switch off and isolate from supply. Water may be left in the water boiler when it
is not in use for short periods, for longer periods it should be emptied and cleaned out.
Protective cut-out
WARNING: The only parts you should touch behind the front panel
are the two red isolation valves. Touching any other part will put you in
danger of receiving an electric shock.
The heating element is fitted with a manual resettable thermal cut out which
protects the water boiler from damage if it were to overheat
D
. If your appliance
flashes 3 times, fails to heat up, appears ‘dead’ when switched on try the following:
Check the water boiler is plugged in to the mains and switched on both at the
plug/ spur and on the front of the unit. If this does not resolve the problem switch
off and disconnect unit, allow to cool, remove front panel (see process below). Reach
in carefully and on the underside of the element, between the two terminals you will
see/feel a reset button.
Press this upwards and the thermostat will reset. We would always recommend
descaling the water boiler after re-setting the thermostat as this is the most
common reason for the safety thermostat to have triggered.
If the safety thermostat activates repeatedly, even after descaling, contact the
Burco customer helpline.
After resetting the cut-out replace the front panel and top black plastic lid.
Reconnect to mains and switch on at plug/spur and on the front of the unit. If the
water boiler still appears dead contact Burco helpline.
Cleaning
WARNING: Disconnect from the electrical supply before cleaning
and allow the water boiler to cool.
IMPORTANT Do not immerse the water boiler in water or any other liquids and
take care to keep water away from the mains lead and connections.
There are two ways in which you will need to clean your autofill water boiler:
Externally; to do this follow external cleaning guidelines
Internally; to do this follow the Easy Descale Procedure below
IMPORTANT Do not use any abrasive cleaning fluids or materials.
External cleaning guidelines
WARNING: Always disconnect the plug from the mains and allow to
cool before cleaning.
To clean wipe the outside of your autofill water boiler with a damp cloth. It is
recommended that this is done daily. Stubborn stains may be removed using a good
stainless steel cleaner or non-abrasive cleaner.
Hard to reach areas should be cleaned using a small bristle brush and mild
cleaner.
IMPORTANT: Do not use abrasive cleaners on your water boiler as this could
scratch the finish of your water boiler.
To remove front panel of unit
•
Remove black plastic lid
1.
•
Using screw driver remove two retaining screws
•
Lift front panel slightly to disconnect front panel at top of the curved front
panel so that hole for the tap goes over the lower part of the top and lift
vertically over the rest of the tap
F
.
•
Pull front panel forward while lifting hole for tap over base tap fitting.
•
Lift front panel over top of tap fitting.
WARNING: When replacing the front of panel, ensure that wires do
not get trapped between tap and front panel.
Reset
button
D
E
F
A5 Autofill counter top ib 6/4/06 4:37 pm Page 7