background image

 

 

THIS URN IS NOT INTENDED TO CONTINUOUSLY BOIL WATER, DUE TO THE HAZARDS OF STEAM 

AND WATER ESCAPING FROM UNDER THE LID. 

If it is necessary to keep the water at an exact temperature, use a thermometer to check. Stir the 

water before taking the temperature and when the desired temperature has been reached, turn the 

control knob slowly to the left until a click from the thermostat is heard. The thermostat will then 

cycle on and off to maintain the temperature. 

4.1.2 Safety tap 

The tap is locked or unlocked by turning the tap lever so that either the closed or opened padlock 

symbol is lined up with the white dot at the front of the tap body. 

There are two open positions, one self-holding so that the tap remains open, and the other self-

closing so that the tap closes as soon as the lever is released. To change the tap position, turn the 

tap lever through 180°. 

Open the tap by depressing the lever tap to the horizontal position. Close the tap by returning the 

lever to the vertical position. 

4.1.3 After use 

Turn the control knob to 0 and disconnect from the mains supply. 

Water may be left in the urn when not in use for short periods, but to maintain a supply of fresh 

water, it should be emptied periodically and cleaned out. 

4.1.4 Protective Cutout 

The heating element is fitted with a thermal cut-out which protects the urn from damage if allowed 

to boil dry or switched on without water. It is essential to keep the heating element free from scale 

to ensure correct operation of this cut-out. Scale can cause the cut-out to operate when water is 

heating up normally. 

If the cut-out operates, allow the urn to cool down, drain out any water then press the red reset 

button situated under the base. 

4.1.5 Cleaning 

 

ALWAYS TURN OFF THE POWER SUPPLY AND REMOVE THE PLUG BEFORE CLEANING, ALLOW 

Knob setting 

Approximate water 

temp 

37°C (99°F) 

55°C (131°F) 

68°C (155°F) 

82°C (180°F) 

5-6 

97°C (207°F) 

Содержание 444448528

Страница 1: ...444448528 444448529 444448530 Glen Dimplex UK Ltd trading as Glen Dimplex Heating Ventilation Millbrook House Grange Drive Hedge End Southampton SO30 2DF Web www gdhv com Glen Dimplex Europe Ltd Airp...

Страница 2: ...efore Connection to Power Supply 4 3 2 2 Location 4 3 2 3 Electrical Connection 5 4 0 User Guide 6 4 1 Filling 6 4 1 1 Controls 6 4 1 2 Safety tap 7 4 1 3 After use 7 4 1 4 Protective Cutout 7 4 1 5 C...

Страница 3: ...s put water in the urn before switching on lift the lid and Fill with the desired amount of water Do not fill above the max capacity mark 1 2 Warning If the urn is over filled there is a risk that boi...

Страница 4: ...h European Community Directives CE for household and similar electrical appliances and Gas appliances where applicable This appliance conforms to European Directive 2009 125 EC regarding Eco design re...

Страница 5: ...following Wire Colour Wire Name Wire Code Green Yellow Wires Earth E Blue Wire Neutral N Brown Wire Live L The wire which is coloured green and yellow must be connected to the terminal in the plug wh...

Страница 6: ...EMOVE THE PLUG WHEN NOT IN USE BEFORE CLEANING AND BEFORE REPLACING ANY PARTS 4 1 Filling Lift the lid and fill to the desired level Do not fill above the MAX indicator Take care not to under fill as...

Страница 7: ...ever through 180 Open the tap by depressing the lever tap to the horizontal position Close the tap by returning the lever to the vertical position 4 1 3 After use Turn the control knob to 0 and discon...

Страница 8: ...ry descaling agent recommended for stainless steel kettles Follow the instructions provided with the descaling product Scale build up can also cause the tap to drip If this should occur turn off the p...

Страница 9: ...9 5 0 Wiring Diagram Electric Catering URN...

Страница 10: ...20290 Thermostat knob kit 1 62100 Thermostat control knob 1 082626774 Neon green 1 082626777 Tap assembly 1 082626760 Tap actuator 1 60109 Handle assembly 2 62657 Reset rod tube 1 62784 Conical spring...

Страница 11: ...nor does it cover damage resulting from misuse accident or unauthorized alterations to the appliance Proof of purchase will be required In any communication with the supplier or manufacturer quote the...

Страница 12: ...and guarantee terms without prior notice due to a policy of continuous improvement To speak to customer services please contact UK ROI Glen Dimplex UK LTD Millbrook House Grange Drive Hedge End Southa...

Отзывы: