Burcam F80350 Скачать руководство пользователя страница 4

PART LIST

PARTS 

DESCRIPTION

F10100 

Circuit board.

F10000 

Relative humidity sensor kit.

F01352 

Fan and motor.

F01254 

Evacuation pipe.

F01255 

Louver vent hood

F01450 

Garage Fan Air housing.

The seasonal setting are :

 

Summer :  

 Relative Humidity at   45%  

or less 

Low speed. 

Relative Humidity at   46% 

or more 

High speed.

 

Winter :  

 Relative Humidity at 

55%  

or less 

Low speed. 

Relative Humidity at 

56% 

or more 

High speed.

It is possible to override the seasonal settings. To keep the system at high speed, 

push the right side button. To keep the system at low speed, push the left side 

button. To cancel the override process, push the same button again.

Note:

 When you override the seasonal setting, the LED light of the overridden 

season remains on.

4