TROUBLE 

PROBABLE CAUSE 

ACTION

Switch is off position

Blown fuse

Tripped breaker

Dirty pressure switch

Defective pressure switch

Defective motor

Pump not primed

Leaky suction line

Foot valve plugged

Ejector nozzle clogged

Water level below foot valve

Suction lift to great

Improper voltage

Water level below foot valve

Ejector nozzle clogged

Excessive friction in pipe

Improper voltage

Leaky discharge line

Motor not up to normal speed

Improper setting of pressure switch

Ejector nozzle clogged

Pressure tank waterlogged

Leaky foot valve

Leaky suction line

Foot valve do not close properly

Pressure switch out of adjustment

Leaky discharge line (toilet etc.)

Leaky suction line

Gaz in water

Airlogged tank (galvanized)

Turn switch to on position

Replace

Reset

Clean

Replace

Replace

Prime with clean water

Check pipe and pipe connections

Clean

Clean

Check foot valve level

Water level lower than lift capacity

Check voltage

Check foot valve level

Clean

Too small or dirty pipe

Check voltage

Check all pipes for leak

Check power cable and voltage

Reset or replace

Clean

Drain tank and restart

Replace

Check pipe and pipe connections

Clean or replace

Adjust on/off setting

Check all pipes for leak

Check pipe and pipe connections

Check and consult factory

Replace air volume control

TO THE END CONSUMER

If you have any problems with the product, before advising the store, where you’ve purchased the 

pump, please contact us at 514 337-4415 , and ask for our sales department, and they will be pleased to 

help you with any questions you might have, concerning your installation.

Motor does  

not run.

Motor runs  

but no water is 

delivered.

Pump does not 

deliver to full 

capacity.

Pump does not 

shut off.

Pump starts 

and stop too 

often.

Air spurts from 

fawcets.

10

Содержание 506518SS

Страница 1: ...ailures Report any damage to your carrier or your point of purchase MODEL 506518SS AND BY PRODUCTS LIKE 506547SS 506548SS ETC JET PUMP 506537SS 506538SS 506541SS Factory set voltage 115 V Connecting volatge changing Before changing the voltage connection A Ensure the power to the pump is disconnected B Open motor junction box cover C Please select the up knob position for 115 V or down knob positi...

Страница 2: ...male adaptors 750865 or 750871 8 1 stainless steel clamps 750885 Teflon tape Tools Screwdrivers hacksaw to cut pipe knife to assist in pipe cutting round file to smooth pipe ends pipe wrench adjustable wrench to tighten fittings A B C D NOTICE This unit is not designed for applications involving salt water or brine Use with salt water or brine will void warranty Tank installation Desired length of...

Страница 3: ...eratures and good ventilation should be considered as well to provide the pump an environment for long life Locating the pump as close as possible to the water source will reduce friction losses encountered in the suction pipe Friction losses in the suction pipe must be taken into consideration when the horizontal offset is greater than 50 feet The suction pipes should be increased from 1 to 1 1 4...

Страница 4: ...ate the suction inlet in the front of the injector Thread an adaptor into inlet using teflon tape Do not over tighten Cut the desired length of pipe from pump location to the well seal and connect both ends using the previous way with stainless steel clamps and torch Do not fill in your trench to the house until you have checked for any leaks in your connections or trouble in your water system San...

Страница 5: ...ter valve 2 PSI below pressure switch ON setting Turn power back on to pump Your tank is now well precharged Run the pump through a few cycles to verify that it works properly Other types of tanks may be used as galvanized standard tanks epoxy or glass lined tanks These products do not achieve the benefits of the captive air tanks Epoxy or glass lined tanks with float have to be precharged by the ...

Страница 6: ...er operating pressures Adjustment or modification of start stop setting of pressure switch have to be done carefully Turn adjustment nut half turn at a time Turn nut 1 clockwise to raise start and stop pressure setting Never turn nut 2 This will change the 20 PSI range between start and stop pressure and may damage your tank s bladder or modify the efficiency of your water system Check system oper...

Страница 7: ...and piping into well casing STEP 5 Install your pump and thread an adaptor into inlet STEP 6 Cut poly pipe and connect both ends STEP 7 You may install one or more sand points to increase the supply of water Check valve close to pump SHALLOW WELL APPLICATION STEP 2 Cut poly pipe and install the foot valve 7 ...

Страница 8: ...ection Pressure gauge 1 4 connection 1 MNPT or 3 4 FNPT connection Relief valve for pumps with more than 75 PSI of capacity 1 2 connection To home s plumbing distribution line From well Snifer valve to adjust air pressure STEP 9 Connect the pump discharge to the tank T 8 ...

Страница 9: ...uge 4 510003 Pump boby screw 6 5 510004 Venturi O Ring 6 510005 Venturi Diffuser 7 510006 Impeller 8 510007 Washer 9 510008 Mechanical seal 10 510009 Seal plate O Ring REF ITEM DESCRIPTION 11 510010 Seal plate 12 510011 Water slinger 13 510012 Motor 14 510013 Capacitor 15 510014 Jonction box cover 16 510015 Motor foot 31 510016 Tube fitting 32 510017 Tube 33 510018 Pressure switch 1 2 4 6 9 5 7 10...

Страница 10: ...ion line Gaz in water Airlogged tank galvanized Turn switch to on position Replace Reset Clean Replace Replace Prime with clean water Check pipe and pipe connections Clean Clean Check foot valve level Water level lower than lift capacity Check voltage Check foot valve level Clean Too small or dirty pipe Check voltage Check all pipes for leak Check power cable and voltage Reset or replace Clean Dra...

Отзывы: