![Burcam 503121S/503221SANDBY- PRODUCTS LIKE503127S, 503128S,503228S, 503131S,503231S Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/burcam/503121s-503221sandby-products-like503127s-503128s-503228s-503131s-503231s/503121s-503221sandby-products-like503127s-503128s-503228s-503131s-503231s_installation-instructions-manual_2831327002.webp)
FOR INFORMATION TEL: 514.337.4415 FAX: 514.337.4029
SAFETY INSTRUCTIONS:
This fine pump that you have just purchased is designed from the latest in material and
workmanship.
Before installation and operation, we recommend the following procedures:
CHECK WITH YOUR LOCAL ELECTRICAL AND PLUMBING CODES TO
ENSURE YOU COMPLY WITH THE REGULATIONS. THESE CODES HAVE
BEEN DESIGNED WITH YOUR SAFETY IN MIND. BE SURE YOU COMPLY
WITH THEM.
WE RECOMMEND THAT A SEPARATE CIRCUIT BE LEAD FROM THE HOME
ELECTRICAL DISTRIBUTION PANEL PROPERLY PROTECTED WITH A
FUSE OR A CIRCUIT BREAKER. WE ALSO RECOMMEND THAT A GROUND
FAULT CIRCUIT BE USED. CONSULT A LICENSED ELECTRICIAN FOR ALL
WIRING.
THE GROUND TERMINAL ON THE THREE PRONG PLUGS SHOULD NEVER
BE REMOVED. THEY ARE SUPPLIED AND DESIGNED FOR YOUR PRO-
TECTION.
NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR
PRODUCT WITH THE POWER CONNECTED. DO NOT ONLY UNSCREW
THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER PLUG FROM
THE RECEPTACLE.
A
B
C
D
Material required for drilled well application
(indoor use only)
Shallow well pump installation
Desired length of polyethylene 1” pipe, 100 PSI, CSA or
UL approved, to link up from pumping level to pump.
1 1” foot valve (750756 or 750752P).
1 well seal, as per well casing diameter (750929 6” x 1”).
1 1” well seal elbow (750860).
2 1” male adaptors (750865 or 750871).
8 1” stainless steel clamps (750885).
Teflon tape.
2
Tools
Screwdrivers, hacksaw to cut pipe, knife to assist in pipe cutting, round file to smooth pipe ends, pipe wrench,
adjustable wrench to tighten fittings, propane torch and welding material.
Tank installation
Desired length of 1” braided hose (750919) to link up from
pump to tank. Keep tank as close as possible from pump.
1 tank T (650651).
1 drain valve (650659)
2 1” female adaptor.
1 1” male adaptor (750865 or 750871).
3 1” stainless steel clamps (750885).
Teflon tape.