6
TROUBLE SHOOTING GUIDE CHECKLIST
NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER
CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER
FROM THE RECEPTACLE.
Switch is off position
Blown fuse
Tripped breaker
Disconnected plug
Corroded plug
Float stuck
Defective switch
Defective motor
Improper voltage
Pump may be airlocked
Pump discharge head too high
Clogged inlet/impeller
Improper voltage
Pump may be airlocked
Pump discharge head too high
Clogged inlet/impeller
Defective switch
Missing check valve
Clogged check valve in open position
Float obstruction
Turn switch to on position
Replace
Reset
Re-install
Clean
Check movement
Replace
Replace
Check voltage
Check drilled hole in discharge pipe
Wrong pump selection (over 15’)
Clean
Check voltage
Check drilled hole in discharge pipe
Wrong pump selection (over 15’)
Clean
Replace
Install valve
Clean debris
Check for movement
TROUBLE PROBABLE CAUSE ACTION
Motor does
not run.
Motor runs but
no water is
delivered.
Pump does not
shut off.
Pump does not
deliver to full
capacity.
TO THE END CONSUMER
If you have any problems with the product, before advising the store, where you’ve
purchased the pump, please contact us at 514 337-4415 , and ask for our sales
department, and they will be pleased to help you with any questions you might have,
concerning your installation.