TROUBLE SHOUTING GUIDE CHECKLIST
NEVER MAKE ADJUSTEMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH
THE POWER CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER,
REMOVE THE POWER FROM THE RECEPTACLE.
TROUBLE
PROBABLE CAUSE
ACTION
Motor does
Switch is off position
Turn switch to on position
not run.
Blown fuse
Replace
Tripped breaker
Reset
Plug disconnected
Re-install
Corroded plug
Clean prongs
Low water level
Add water and verify
Thermal overcharge
Cool the motor
Defective switch / float
Replace
Defective motor
Replace / repair
Improper float position
Check movement
Pump does not
Jammed impeller
Clean
deliver to full
Plugged check valve
Clean / replace
capacity.
Blocked suction / inlet
Check for debris in pit and clean
Discharge leak
Repair
Blocked line / pipe
Check for debris or ice
Worn impeller
Repair / replace
Defective motor
Replace
Pump does not
Defective switch
Replace
shut off.
Float obstruction
Adjust / check
Blocked suction / inlet
Check for debris in pit and clean
TO THE END CONSUMER
If you have any problems with the product, before advising the store, where
you’ve purchased the pump, please contact us at 514 337-4415, and ask
for our sales departement, and they will be pleased to help you with any
questions you might have, concerning your installation.
6