Bunn VP17 Series Скачать руководство пользователя страница 3

Page 3

SERVICE

 

This manual provides procedures for testing and 

replacing various major components used in this 

brewer should service become necessary.  Refer to 

Troubleshooting for assistance in determining the 

cause of any problem.
WARNING - Inspection, testing, and repair of electri-

cal equipment should be performed only by qualified 

service personnel.  The brewer should be unplugged 

when servicing, except when electrical tests are re-

quired and the test procedure specifically states to 

plug in the brewer.

COMPONENT ACCESS
WARNING
 - Disconnect the brewer from the power 

source before the removal of any panel or the replace-

ment of any component.
  All components are accessible by the removal of 

the top cover and front inspection panel and warmer 

assemblies.

The top cover is attached with one #4-40 screw.

The front inspection panel is attached with four #6-32 

screws.

The warmer assembly is attached with three #4-40 

screws.

Contents

Control Thermostat .............................................. 4

Limit Thermostat .................................................. 5

ON/OFF Switch ..................................................... 6

Tank Heater .......................................................... 7

Tank Heater Switch .............................................. 8

Warmer Elements............................................... 10

Wiring Diagrams ................................................ 11

P1160.40

46721  052512

FIG. 1 COMPONENT ACCESS

Содержание VP17 Series

Страница 1: ...VP17 Series SERVICE REPAIR MANUAL BUNN O MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD ILLINOIS 62708 3227 PHONE 217 529 6601 FAX 217 529 6644 46721 0000A 05 12 2012 Bunn O Matic Corporation ...

Страница 2: ...ions to this warranty or to make additional warranties that are binding on BUNN Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive op tion while the equipment is under warranty shall either 1 provide at no cha...

Страница 3: ...est procedure specifically states to plug in the brewer COMPONENT ACCESS WARNING Disconnect the brewer from the power source before the removal of any panel or the replace ment of any component All components are accessible by the removal of the top cover and front inspection panel and warmer assemblies The top cover is attached with one 4 40 screw The front inspection panel is attached with four ...

Страница 4: ...ROL THERMOSTAT 7 Disconnect the brewer from the power source Ifvoltageispresentasdescribed reinstallthecapillary tube into the tank to the line 4 5 above the bulb the control thermostat is operating properly If voltage is not present as described replace the thermostat Removal and Replacement 1 Remove wires from control thermostat leads 2 Remove the thermostat capillary bulb by firmly pulling up o...

Страница 5: ...rminals Ifcontinuityispresentasdescribed thelimitthermostat is operating properly If continuity is not present as described replace the limit thermostat Removal and Replacement 1 Remove all wires from limit thermostat termi nals 2 Carefully slide the limit thermostat out from under the retaining clip and remove limit thermostat 3 Carefully slide the new limit thermostat into the retaining clip 4 R...

Страница 6: ...o Fig 7 when reconnecting the wires P1918 SERVICE cont ON OFF WARMER SWITCH Location The ON OFF warmer switch es are located on the front of the hood Test Procedure 1 Disconnect the brewer from the power source 2 Viewing the switch from the back remove the white wire from the upper terminal and the black wire from the center terminal 3 With a voltmeter check the voltage across the white wire and t...

Страница 7: ...t all three parts aside for reassembly 2 Disconnect the black wire on the limit thermostat from the tank heater switch and disconnect the blue wire from the limit thermostat to the control thermostat 3 Disconnect the black wire and the white wire from the tank heater terminals 4 Remove sprayhead and the hex nut securing the sprayhead tube to the hood Set aside for reas sembly 5 Remove the eight 8 ...

Страница 8: ...roperly If continuity is not present as described replace the tank heater switch Removal and Replacement VP17 1 Remove the tank inlet fitting securing fill basin to the tank lid Remove fill basin and gasket Set all three parts aside for reassembly 2 Removesprayheadandhexnutsecuringsprayhead tube to the hood Set aside for reassembly 3 Disconnect the wires on the limit thermostat and the tank heater...

Страница 9: ...to the tank lid Remove fill basin and gasket Set all three parts aside for reassembly 2 Disconnectthetwoblackwiresfromthetankheater switch 3 Remove the plastic facenut hex facenut and the switch indicator guard bracket that secures tank heater switch to the brewer Remove switch and discard 4 Insert new tank heater switch through the hole in the lower left of the control panel and secure with swtic...

Страница 10: ...resent as described reconnect the white wire and white red brown black or violet wires on the warmer element P1164 If continuity is not present as described replace the warmer element Removal and Replacement 1 Remove the three 4 40 screws securing the warmer assembly to the brewer 2 Lift the warmer assembly from the brewer 3 Disconnectthetwowiresfromthewarmerelement terminals 4 Remove the two 8 32...

Страница 11: ... GND SINGLE PHASE BLK BRN BLK BRN BLK BLK VIO VIO VP17 3 2 SIDE WARMERS 1320W BLK TANK HEATER L1 GRN BLK BLU SW THERMOSTAT ON OFF SWITCH WHI RED KEEP WARM HEATER 50W WHI BLK LIMIT THERMOSTAT WHI REAR WARMER WHI WHI P3 P1 VIO BLK VP17 2 TOP WARMER ASSY VIO WHI ON OFF SWITCH ON OFF SWITCH ON OFF SWITCH NOT USED ON LATE MODELS WITH SIDE WARMERS FRONT WARMER REAR WARMER ...

Страница 12: ... VOLTS AC 2 WIRE SINGLE PHASE BLK BRN BLK BLK VIO 2 TOP or SIDE WARMERS AUXILIARY OUTLET NOT AVAILABLE ON VP17 3 BLK TANK HEATER L1 GRN BLK HEATER SWITCH BLK BLU READY INDICATOR BLU SW THERMOSTAT ON OFF SWITCH WHI RED KEEP WARM HEATER WHI BLK LIMIT THERMOSTAT BLK WHI REAR WARMER WHI WHI P3 P1 VIO BLK 1 TOP WARMER VIO WHI GRN 200 WATT MAXIMUM WHI BLK BLK ON OFF SWITCH ON OFF SWITCH ON OFF SWITCH ...

Страница 13: ...SE BLK BRN BLK BLK VIO BLK TANK HEATER L1 GRN BLK HEATER SWITCH BLK BLU READY INDICATOR BLU SW THERMOSTAT ON OFF SWITCH WHI RED KEEP WARM HEATER WHI BLK LIMIT THERMOSTAT BLK WHI REAR WARMER WHI WHI P3 P1 VIO BLK 1 TOP WARMER VIO WHI GRN 200 WATT MAXIMUM WHI BLK BLK ON OFF SWITCH ON OFF SWITCH ON OFF SWITCH 2 TOP or SIDE WARMERS NOT USED ON LATE MODELS WITH SIDE WARMERS AUXILIARY OUTLET NOT AVAILAB...

Страница 14: ... or SIDE WARMERS NOT USED ON LATE MODELS WITH SIDE WARMERS 10862 0001L 01 07 1995 BUNN O MATIC CORPORATION 220 240 VOLTS AC 2 WIRE GND SINGLE PHASE BLK L1 L2 BLK RED MAIN ON OFF SWITCH Late Models only 46721 052512 ...

Страница 15: ...Page 15 46721 052512 ...

Страница 16: ...Page 16 46721 052512 ...

Отзывы: