SERVICE (cont.)

CONTROL THERMOSTAT

FIG. 4 CONTROL THERMOSTAT

P2178.60

Location:

The control thermostat is mounted on the right

front of the component bracket.

Test Procedures:
1. Disconnect the brewer from the power source.
2. Locate the thermostat and check for 230 volts

between the red wire from the main harness on the
control thermostat and the black wire on the main
terminal block

3. Disconnect the brewer from the power source.

If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to the

wiring diagram and check the brewer wiring harness.

4. Disconnect the red wires from the control thermo-

stat.

5. Check for continuity across the terminals on the

control thermostat with the control thermostat in
the "ON" position (fully clockwise), continuity must
not be present when the thermostat is in the "OFF"
position (fully counterclockwise).

If continuity is present as described, the control ther-

mostat is operating properly.

If continuity is not present as described, replace the

control thermostat.

Removal and Replacement:

1. Disconnect the wires from the control thermostat.
2. Remove the thermostat capillary bulb by firmly

pulling up on the capillary at the component bracket.
This will disengage the grommet from the compo-
nent bracket.

3. Remove the #8-32 screw securing the control

thermostat and mounting bracket to the compo-
nent bracket. Remove control thermostat and
bracket as an assembly.

4. Remove knob from control thermostat.
5. Remove the two #6-32 screws securing the con-

trol thermostat to the thermostat mounting bracket.
Remove and discard thermostat.

6. Install new control thermostat on thermostat

mounting bracket and secure with two #6-32
screws.

7. Install knob on thermostat.
8. Install thermostat and mounting bracket on the

component bracket and secure with one #8-32
screw.

9. Carefully bend the capillary tube so that the tube

and bulb inside the brewer are in the vertical
position with the grommet located 5 1/2 " above
the capillary bulb.

NOTE: 

The capillary tube must be clear of any electrical

termination and not kinked.

10. Refer to Fig. 5 and reconnect the wires.
11. Adjust the control thermostat as required.

RED from Main
Harness

RED to Limit Thermostat

FIG. 5 CONTROL THERMOSTAT TERMINALS

P1730

10060.3  070102

Содержание U3A

Страница 1: ...NG SERVICE MANUAL BUNN O MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD ILLINOIS 62708 3227 PHONE 217 529 6601 FAX 217 529 6644 www bunnomatic com U3A BUNN 10060 0003A 07 02 2002 Bunn O Matic Corp...

Страница 2: ...ted by BUNN shipping the defective equipment prepaid to an authorized BUNN service location and 3 receiving prior authorization from BUNN that the defective equipment is under warranty THE FOREGOING W...

Страница 3: ...ewer and in this manual They were written for your protection All notices on the brewer are to be kept in good condition Replace any unreadable or damaged labels 00878 0000 12593 0000 03408 0000 03409...

Страница 4: ...cold water system with operating pressure between 20 and 90 psi 138 and 620 kPa from a 1 2 or larger supply line A shut off valve should be installed in the line before the brewer Install a regulator...

Страница 5: ...nect the brewer to the power source and wait for the water in the tank to heat to the proper temperature This will take approximately 1 2 hours depending on the incoming water temperature Some water w...

Страница 6: ...the water stream from the swing arm Release the switch Failure to release the switch within two seconds after the third break in the water stream causes the volume setting to be aborted and previous v...

Страница 7: ...damp cloth 2 Drain both coffee reservoirs by opening coffee faucets When empty close faucets 3 Cycle two or three inches of water into each coffee reservoir adding a bucket of crushed ice to obtain a...

Страница 8: ...airofelectricalequipmentshouldbeperformedonlybyqualifiedservicepersonnel All electronic components have 230 volt ac and low voltage dc potential on their terminals Shorting of terminals or the applica...

Страница 9: ...ng procedures See page 20 Refer to Service Solenoid Valve for testing procedures See page 22 A Direction of flow arrow must be pointing towards brewer B Remove the strainer and check for obstructions...

Страница 10: ...r must be level and installed on a sturdy structure Refer to Service Solenoid Valve for testing procedures See page 22 Refer to Service Liquid Level Board for testing procedures See page 17 Refer to S...

Страница 11: ...rtoService Timerfortesting procedures See page 26 or 28 Refer to Service Start Switch for testing procedures See page 23 RefertoService Timerfortesting procedures See page 26 or 28 Refer to Service So...

Страница 12: ...to Service Timer for test ing procedures See page 26 or 28 Checkpumpflowratewithawatch Pumpflowrateshouldbeapproxi mately 24 ounces in 15 seconds Be sure pump assembly is free of any obstructions Plum...

Страница 13: ...tthebrewerfromthepower source before the removal of any panel or the replace ment of any component All components are accessible by the removal of the swing spout front cupola cover rear cupola cover...

Страница 14: ...ce If voltage is present as described proceed to 9 If voltage is not present as described refer to the wiring diagrams and check the brewer wiring harness 9 Check for continuity across the terminals o...

Страница 15: ...hermostat Removal and Replacement 1 Disconnect the wires from the control thermostat 2 Remove the thermostat capillary bulb by firmly pullinguponthecapillaryatthecomponentbracket This will disengage t...

Страница 16: ...178 60 RED from ON OFF Switch P2112 RED from Main Harness FUSE AND FUSE HOLDER Removal and Replacement Fuse 1 Remove the cap from the fuse holder 2 Remove fuse from the fuse holder inspect if blown di...

Страница 17: ...EVEL BOARD AND LEVEL PROBE P2178 55 Location The liquid level board is located on the left rear of the component bracket The level probe is located on the right rear of the component bracket Test Proc...

Страница 18: ...by touching the end of the probe to any metal surace of the brewer Measure the voltage be tween T1 and T3 on the liquid level board The voltage should be 0 volts with the probe touching the frame and...

Страница 19: ...agram and check the brewer wiring harness 5 Disconnect all wires on the ON OFF switch 6 Check for continuity across the center terminal 2 andthelowerterminal 1 whentheswitchisinthe ON upper position C...

Страница 20: ...pump does not run replace the pump If voltage is not present as described refer to the wiring diagram and check the brewer wiring harness Removal and Replacement Refer to Fig 15 1 Disconnect the wire...

Страница 21: ...must not present when the switch is in the OPEN right full position If continuity is present as described the switch is operating properly If continuity is not present as described replace the switch...

Страница 22: ...ribed reconnect the wires to the solenoid If continuity is not present as described replace the solenoid valve 7 Check the solenoid valve for coil action Connect thedispensertothepowersource Listencar...

Страница 23: ...when the switch is in the upper position If continuity is present as described reconnect the wires the switch is operating properly If continuity is not present as described replace the switch BLU to...

Страница 24: ...operating properly If continuity is not present as described replace the switch Removal and Replacement NOTE Measurethedistancefromthetopoftheswitch plunger to the hood cover The same distance is nee...

Страница 25: ...he brewer from the power source 2 Disconnect the wires from each tank heater 3 Check for continuity across the terminals of each tank heater If continuity is present as described tank heaters are oper...

Страница 26: ...he component bracket Test Procedures 1 Disconnect the brewer from the power source 2 Disconnectthepolarized threepinconnectorfrom the brewer main harness and rotate the brew timer dial fully countercl...

Страница 27: ...uired If voltage is not present as described replace the timer Removal and Replacement 1 Separate all connectors between the brewer wir ing harness and the timer 2 Disconnect the timer leads from the...

Страница 28: ...scribed disconnect the brewer from the power source and replace the timer 7 With a voltmeter check the voltage across termi nals TL1 and TL4 when the ON OFF switch is in the ON position Connectthebrew...

Страница 29: ...stream from the swing arm Release the switch Failure to release the switch within two seconds after the third break in the water stream causes the volume setting to be aborted and previous volume sett...

Страница 30: ...Page 30 10493 0004A 07 02 2002 BUNN O MATIC CORPORATION 10060 3 070102...

Отзывы: