Page 10

TROUBLESHOOTING

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems

encountered.  If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.

Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel.

All electronic components have 120 volt ac and low voltage dc potential on their terminals.  Shorting of
terminals or the application of external voltages may result in board failure.

Intermittent operation of electronic circuit boards is unlikely.  Board failure will normally be permanent.  If an
intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a
terminal or crimp.

Solenoid removal requires interrupting the water supply to the valve.  Damage may result if solenoids are
energized for more than ten minutes without a supply of water.

The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened.  This will help
to avoid twists and kinks in the tubing.

Make certain that all plumbing connections are sealed and electrical connections tight and isolated.

This brewer is heated at all times.  Keep away from combustibles.

WARNING

– • Exercise extreme caution when servicing electrical equipment.

• Unplug the brewer when servicing, except when electrical tests are specified.
• Follow recommended service procedures.
• Replace all protective shields or safety notices.

Before troubleshooting this brewer, check for the following:

A. Control Boards

Make sure ribbon cable is properly attached to the control board (ALL PINS INSERTED INTO PLUG).
Make sure there is a nylon insulating washer under each screw head that holds the control board to the plastic
front end cap. This is important for proper operation.

B. Make sure before servicing brewer that voltage is present at control board.

Press any warmer switch or observe if any indicator lights are glowing on the control panel. If so, proceed with
testing. If not, check for voltage across pins 1 & 2 of the ten pin J1 connector (black and white wires). If voltage
is present, replace the control board. If voltage is not present, check wiring and voltage across terminal block(s)
(black and white). Correct the problem and retest before proceeding with testing.

36672 030104

Содержание TWIN APS

Страница 1: ...CDBC TWIN TWIN APS C A U T IO N...

Страница 2: ...under this warranty by telephone at 217 529 6601 or by writing to Post Office Box 3227 Springfield Illinois 62708 3227 2 if requested by BUNN shipping the defective equipment prepaid to an authorized...

Страница 3: ...9 0002 00656 0000 00658 0000 29007 0000 12364 0000 10044 0000 WARNING DO NOT OVERLOAD CIRCUIT ALWAYS ELECTRICALLY GROUND THE CHASSIS OR ADAPTOR PLUG DO NOT DEFORM PLUG OR CORD FOLLOW NATIONAL AND LOCA...

Страница 4: ...greater than 90 psi 620 kPa to reduce it to 50 psi 345 kPa The water inlet fitting is 3 8 flare Bunn O Matic does not recommend the use of a reverse osmosis or deionized water supply to this equipment...

Страница 5: ...nel is empty NOTE Hot water will be available at the faucet in a limited amount when the ON OFF indicator is not glowing because the tank will not refill BREW SWITCH Momentarily pressing and releasing...

Страница 6: ...server It should be 64 ounces 2 Refer to the adjustments section of this manual should the volume need to be increased or decreased NOTE Repeat steps 1 through 9 for the other brew station The brewer...

Страница 7: ...Page 7 ADJUSTMENTS OPTIONAL SETTINGS HIDDEN SWITCH...

Страница 8: ...y press and release the BREW switch once for each ounce approximate of water to be added to the prior setting and allow the brew cycle to finish To decrease the amount of water for each brew cycle pla...

Страница 9: ...ry The spray will continue the off and on cycles until the brew volume of step 1 is complete Pressing the ON OFF button again will terminate the brewing cycle with the parameters stored in memory 7 If...

Страница 10: ...wists and kinks in the tubing Make certain that all plumbing connections are sealed and electrical connections tight and isolated This brewer is heated at all times Keep away from combustibles WARNING...

Страница 11: ...tall Disconnect the brewer from the power source and remove wires from refill valve coil Check for con tinuity across the terminals of the solenoid coil If continuity is not present replace the refill...

Страница 12: ...and pin 4 of the plug conti nuity should be present Connect the J3 plug to the control board and proceed to step 3 Press ON OFF switch to ON Indi cator lamp should be lit If water continuously flows o...

Страница 13: ...ect the J3 connector from the control board Check for continuity from the tank mounting screw where the green wire mounts to pin 2 of the plug continuity should be present Pull the temperature probe u...

Страница 14: ...1 8k 2k OHMS and at 80 F 27 C the reading should be 9 3k 2k OHMS If the probe is within these parameters recon nect the J3 plug to the control board Disconnect the brewer from the power source Check f...

Страница 15: ...1 C the reading should be 11 8k 2k OHMS and at 80 F 27 C the reading should be 9 3k 2k OHMS If the probe is within these parameters recon nect the J3 plug to the control board Set the temperature to 2...

Страница 16: ...hite terminals at the termi nal block s The indicator lamp must be lit Allow brewer to heat until ready lamp is lit or disable the brew lockout feature See page 7 Press ON OFF switch indicator must be...

Страница 17: ...ty across the terminals of the sole noid coil If continuity is not present replace the solenoid See page 24 If continuity is present the valve may be stuck closed Set up brewer according to in structi...

Страница 18: ...proper extrac tion Place an empty brew funnel on an emptydecanter serverbeneaththe sprayhead Initiate brew cycle and check the water temperature im mediately below the sprayhead with a thermometer The...

Страница 19: ...connect the brewer from the powersource Removethewarmer plate and turn upside down to ex pose the warmer terminals Re move the two wires Check for continuity across the two warmer terminals If continu...

Страница 20: ...Low Tank Level Fault Water pressure is water shut off Level probe dry for 7 minutes after fill valve is energized Level probe wiring Temperature probe wiring Fill valve wiring function strainer 3 Low...

Страница 21: ...Page 21...

Страница 22: ...Page 22 C A U T I O N...

Страница 23: ...DISC AR D DE CA NT ER IF CR AC KE D SC RA TC HE D BO ILE D DR Y HE AT ED WH EN EM PT Y US ED ON HIG H FL AM E OR EX PO SE D EL EC TR IC EL EM EN TS FA ILUR E TO CO MP LY RISK S INJU RY PN 658 198 5 BU...

Страница 24: ...r wear and remove waterborne particles If the sound is not heard as described proceed to 6 P1877 P1853 WHI GRN from PC Control Board WHI from Terminal Block FIG 5 DISPENSE VALVE WIRING FIG 4 DISPENSE...

Страница 25: ...Page 25...

Страница 26: ...the top of the tank by pulling the elbow fitting from the grommet in the top of the tank lid 3 Drain water from the tank 4 Disconnect the water supply tube to the dispense valve from the side of the...

Страница 27: ...and attach the black lead from the clip to the sheath 24 Install the elbow fitting of the vent hose into the grommet in the tank lid 25 If installing left tank on brewers with faucet connect the outle...

Страница 28: ...Page 28 C A U T I O N C A U T I O N C...

Страница 29: ...Page 29 C A U T IO N C A U T IO N C A U T IO N...

Страница 30: ...3 WIRE SINGLE PHASE 120 208V AC 3 WIRE 120 240V AC 3 WIRE SINGLE PHASE YEL WHI VIO WHI VIO WHI VIO BLK WHI YEL YEL W H I LEFT CONTROL PANEL ASSY J2 1 J2 6 J2 11 BREW SW STATIC SHIELD ON OFF SW HIDDEN...

Страница 31: ...NTER OPTIONAL 120 208V AC 3 WIRE 120 240V AC 3 WIRE SINGLE PHASE 120 208V AC 3 WIRE 120 240V AC 3 WIRE SINGLE PHASE VIO VIO BLK WHI LEFT CONTROL PANEL ASSY J2 1 J2 6 J2 11 BREW SW STATIC SHIELD ON OFF...

Страница 32: ...BLU WHI BLU COUNTER OPTIONAL 120 208V AC 3 WIRE 120 240V AC 3 WIRE SINGLE PHASE 120 208V AC 3 WIRE 120 240V AC 3 WIRE SINGLE PHASE BLK WHI LEFT CONTROL PANEL ASSY J2 1 J2 6 J2 11 BREW SW STATIC SHIEL...

Отзывы: