TROUBLESHOOTING (cont.)

PROBLEM

PROBABLE CAUSE

REMEDY

not present, replace the refill valve.   

If continuity is present, the coil may 

be stuck closed. Shut water off to 

brewer. Press the ON/OFF switch to 

turn off the brewer.  Open the faucet 

and drain water down in the tank 

until flow stops or slows to a trickle.   

Attach a voltmeter to the terminals 

of the refill solenoid. Connect the 

brewer to the power source. Press 

the ON/OFF switch to turn the brewer 

on. Within five seconds, voltage 

should be present at the solenoid 

terminals. If voltage is not present, 

refer to the wiring schematic and 

check the wiring harness.

Substitute a control board known 

to be in good working order.

ON/OFF switch must be ON for the 

refill circuit to operate. Turn ON.

When this condition occurs, the 

brewer will display OVERFLOW 

CUP FULL. EMPTY CUP. The reason 

for overfilling could be a defective 

refill valve, an incorrect sensitivity 

setting, (see above) or boiling.

4. Control Board

5. ON/OFF Switch

6. Overflow Safety Switch

Automatic refill will not operate or 

display shows FILL TIME TOO LONG 

(Continued)

41747 112608

RELEASED FOR PRODUCTION

DIR Num: 41747.0000             12, December 2018

Содержание TITAN SINGLE

Страница 1: ...POST OFFICE BOX 3227 SPRINGFIELD ILLINOIS 62708 3227 PHONE 217 529 6601 FAX 217 529 6644 www bunn com 41747 0000D 10 18 2008 Bunn O Matic Corporation ENA BLE I O TITAN ENA BLE ENA BLE I O BRE W I O B...

Страница 2: ...hether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive op...

Страница 3: ...brewing process such as brew tempera ture brew volumes bypass percentages pulse brew etc Other features are Energy Savings mode Freshness Timer and Clean Alert CONTENTS Warranty 2 Table of Contents 3...

Страница 4: ...ion is encountered the cause will likely be a switch contact or a loose connection at a terminal or crimp Solenoid removal requires interrupting the water supply to the valve Damage may result if sole...

Страница 5: ...con nection 1 Temperature Sensor Probe wire s shorted to housing or to each other 1 No power or incorrect voltage A Wait for the brewer to heat to the proper temperature B Disable the BREW LOCKOUT fun...

Страница 6: ...ch procedures on page 17 Test the brew valve Refer to the testoutputsproceduresonpage15 Substitute a control board known to be in good working order Checkplumbingandshut offvalves Remove the strainer...

Страница 7: ...te that theleftnumberchangesfromahigh value when water is NOT touching the refill probe to a low valve when water IS touching the probe For best operation the right number should be set to a value mid...

Страница 8: ...tage should be present at the solenoid terminals If voltage is not present refer to the wiring schematic and check the wiring harness Substitute a control board known to be in good working order ON OF...

Страница 9: ...nedontofillthetank Theright numberisthethresholdsettingand can be adjusted to compensate for extremewaterconditions verypure low conductance water requires a higher setting while high mineral content...

Страница 10: ...OHMS at 70 F 21 C the reading should be 11 8k 2k OHMS and at 80 F 27 C the reading should be 9 3k 2k OHMS If the probe is withintheseparameters reconnect to the control board Remove power from the bre...

Страница 11: ...ector At 60 F 16 C the reading should be 15 3k 2k OHMS at 70 F 21 C the reading should be 11 8k 2k OHMS and at 80 F 27 C the reading should be 9 3k 2k OHMS If the probe is withintheseparameters reconn...

Страница 12: ...fbypassisbeingusedontheincon sistent brew test the bypass valve Refer to test outputs on page 15 Turnthevalveonfor30secondsand collect the water collected from the funnel Repeatthetestseveraltimes to...

Страница 13: ...cycle The mounting screws on the so lenoids must be tight or they will vibrate during operation Plumbinglinesshouldnotberesting on the countertop The brewer must be connected to a cold water line Wat...

Страница 14: ...funnel and the bed of grounds leveled by gently shak ing Use the four wire loops on the funnel to hold filter in place while brewing Empty the server remove its cover and place the server beneath the...

Страница 15: ...ing the previous one 8 The display should now read BYPASS VALVE on SINGLE brewers BYPASS VALVE on DUAL brewers To test the left bypass valve press ON If the bypass valve is functional water should run...

Страница 16: ...ASS ON NEXT OFF RIGHT FUNEL LOCK ON NEXT OFF REFILL VALVE ON NEXT OFF TANK HEATR RELAY ON NEXT OFF BREW VALVE ON NEXT OFF BYPASS ON NEXT OFF FUNNEL LOCK ON NEXT OFF SINGLE BREWERS DUAL BREWERS EXIT TO...

Страница 17: ...in the TEST SWITCHES screen to test the switches The display will read NOTHING PRESSED 6 From this screen press any of the switches on the front of the brewer except the upper right hidden switch Whil...

Страница 18: ...2 With the power connected to brewer the voltage reading to the board should be the line voltage rated for that model If no voltage is present check wiring to the board If voltage is present and brew...

Страница 19: ...hree commons in this circuit pins 9 10 21 Disconnect brewer from power source before discon necting ribbon cable from control board Removal and Replacement 1 Disconnecttheribboncablefrom22 pinconnecto...

Страница 20: ...Diagrams and check the brewer wiring harness Also check the control board and switch for proper operation Removal and Replacement 1 Disconnect the brewer from the power source 2 Disconnect wires from...

Страница 21: ...valve in the test mode With a voltmeter check the voltage across the coil wires 3 Theindicationmustbe120voltsacfor120 208and 120 240 volt models or 230 volts ac for 230 400 volt models If voltage is p...

Страница 22: ...placement 1 Remove the top cover from the brewer 2 Disconnect the wires from tank heater terminals 3 Remove the four 8 32 nuts securing the tank heater s to the tank lid assembly 4 Removetankheater s...

Страница 23: ...sent as described proceed to 4 4 Disconnect temperature probe from J13 on con trol board Check the resistance across the two terminalsofthetemperatureprobe Theindication should be aproximately between...

Страница 24: ...be 208 volts ac for 120 208 volt models 240 volts ac for 120 240 volt models or 230 volts ac for 230 400 volt models 7 Disconnect the brewer from the power source If voltage is present as described p...

Страница 25: ...FUNNEL LOCK Optional BRN BLK BRN WHI SOL SOL DISPENSE TRANSFORMER 10VA J16 1 J16 5 J20 1 J20 3 LEFT FULL LEFT FULL LEFT HALF LEFT HALF LEFT ON OFF LEFT ON OFF RIGHT BREW C LEFT BREW A RIGHT PROG LEFT...

Страница 26: ...F LEFT ON OFF RIGHT BREW C LEFT BREW A RIGHT PROG LEFT BREW C RIGHT FULL RIGHT FULL RIGHT HALF RIGHT HALF RIGHT ON OFF RIGHT ON OFF LEFT BREW B TANK HEATER 1 CONTACTOR BLK 12 BLU 12 RED 12 BLK 12 VIO...

Страница 27: ...RED RED WHI GRN LEVEL PROBE t J13 1 SWEETENER INJECTOR SOL SOL FUNNEL LOCK Optional BRN BLK BRN WHI SOL SOL DISPENSE TRANSFORMER 10VA J16 1 J16 5 J20 1 J20 3 LEFT FULL LEFT FULL LEFT HALF LEFT HALF L...

Страница 28: ...T FUNNEL LOCK Optional BRN BLK BRN WHI SOL RIGHT FUNNEL LOCK Optional BLU BLU BLK SOL SOL WHI RIGHT BYPASS SOL WHI ORN LEFT DISPENSE SOL TRANSFORMER 10VA J16 1 J16 5 J20 1 J20 3 LEFT FULL LEFT FULL LE...

Страница 29: ...K Optional BLU BLU BLK SOL SOL WHI RIGHT BYPASS SOL WHI ORN LEFT DISPENSE SOL TRANSFORMER 10VA J16 1 J16 5 J20 1 J20 3 LEFT FULL LEFT FULL LEFT HALF LEFT HALF LEFT ON OFF LEFT ON OFF RIGHT BREW C LEFT...

Страница 30: ...FUNNEL LOCK Optional BLU BLU BLK SOL SOL WHI RIGHT BYPASS SOL WHI ORN LEFT DISPENSE SOL TRANSFORMER 10VA J16 1 J16 5 J20 1 J20 3 LEFT FULL LEFT FULL LEFT HALF LEFT HALF LEFT ON OFF LEFT ON OFF RIGHT B...

Отзывы: