TROUBLESHOOTING GUIDE (Continued)
LCD DISPLAY
ERROR
DESCRIPTION/TROUBLESHOOTING
MENU
(-)
(+)
C
E 0 0 7
MENU
(-)
(+)
C
E 0 0 8
MENU
(-)
(+)
C
E 0 0 9
MENU
(-)
(+)
C
E 0 1 0
MENU
(-)
(+)
C
E
1 1
0
Tank Temp Sensor Failed
Cooling Temp Sensor Failed
Heat Sink Temp Sensor Failed
Overflow Switch Fault
Power Supply Fault
Sensor Reading Out Of Range (High
or Low). Faulty Sensor wiring.
Sensor Reading Out Of Range (High
or Low). Faulty Sensor wiring.
Sensor Reading Out Of Range (High
or Low). Faulty Sensor wiring.
Water In Overflow Cup. Check liquid
level probe in tank lid for lime builup.
Check level probe wiring for open cir-
cuit.
Excessive load on power supply, or
failing power supply.