Procedure to adjust the flow rate setting:
1. Press and hold the ® pad until the display reads
SET NEW RECIPES
. Release the ®. Press and
release the ® pad until the display reads
BYPASS
OZ/M
. The number represents what the brewer
thinks is the flow rate of the bypass valve in ounces
per minute.
2. If the actual flow rate of the bypass valve is known,
but is different than the number on the display, use
the
(-)
and
(+)
pads to enter the correct flow rate
in ounces per minute.
3. When finished, press and release the
DONE
pad.
This saves the new setting and advances to the
next function screen,
CALIBRATE FLOW.
Another
alternative is to press and release the
pad
located on the front switch panel to exit the
BY-
PASS OZ/M
function and return to the
MAIN
SCREEN.
P2306
Procedure to set the sensitivity threshold of the refill
circuit:
NOTE:
Make sure the water in the tank is touching the
refill probe.
1. Press and hold the ® until the display reads
SET
NEW RECIPES
. Release the ®. Press and release
the ® pad until the display reads
REFILL
and
shows a number on both sides of the word.
2. To adjust the threshold setting, press
(-)
to de-
crease, or
(+)
to increase the setting.
NOTE:
Always make sure that the number on the right
is larger than the number on the left when water is in
contact with the refill probe in the tank.
3. When finished, press and release
DONE
. This
saves the new setting and advances to the next
function screen,
SPRAY OZ/M.
Another alterna-
tive is to press and release the
pad located on
the front switch panel to exit
REFILL
and return to
the
MAIN SCREEN.
SPRAY OZ/M
This function allows the operator to view or to
enter the actual flow rate coming out of the sprayhead
of the brewer. This is
NOT
used to change the actual
flow rate, but to tell the internal controller how fast the
water is flowing. The unit of measure is ounces per
minute (OZ/M).
Procedure to adjust the flow rate setting:
1. Press and hold the ® pad until the display reads
SET NEW RECIPES
. Release the ®. Press and
P2304
P2305
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
REFILL - Range: 0 to 155
This function allows the operator to adjust the
sensitivity of the refill circuit. This is mainly a trouble-
shooting feature. Water in different geographical loca-
tions can have different conductivities. By adjusting
the sensitivity of the refill circuit, this will allow the
brewer to operate under various water conditions.
release the ® pad until the display reads
SPRAY
OZ/M
. The number represents what the brewer
thinks is the flow rate of the sprayhead in ounces
per minute (OZ/M).
2. If the actual flow rate of the sprayhead is known,
but is different than the number on the display, use
the
(-)
and
(+)
pads to enter the correct flow rate
in ounces per minute.
3. When finished, press and release
DONE
. This
saves the new setting and advances to the next
function screen,
BYPASS OZ/M.
Another alterna-
tive is to press and release the
pad located on
the switch panel to exit and return to the
MAIN
SCREEN.
BYPASS OZ/M
This function allows the operator to view or to
enter the actual flow rate coming out of the bypass
nozzle. This is
NOT
used to change the actual flow rate,
but to tell the internal controller how fast the water is
flowing. The unit of measure is ounces per minute (OZ/
M).