18
Ratio Dispense Test Set Up Procedure
1. Place the Program switch in the ON position.
2. Water flow rate should be factory pre-set to 133 ml (4.5 oz) per 3 second dispense. To verify, place a graduated measuring
cylinder under the dispense nozzle, pull and release the tapper handle 3 times. The dispenser will then dispense an amount
of water for 3 seconds. Record the water output for later reference on each dispense head.
3. Pull and release the tapper handle 6 times. The dispenser will then dispense an amount of concentrate for 3 seconds.
• For best results, discard the first two samples before recording output. Repeat the same practice after every adjustment.
4. Record the amount dispensed. NOTE – Measuring in milliliters is required for accuracy.
5. Refer to the Ratio chart below to confirm proper volumes for desired ratios. Concentrate amounts for each ratio are high-
lighted in yellow under the ratio number.
6. To increase or decrease the product output, refer to Step 10 of SET-UP INSTRUCTIONS.
7. Place the Program switch back to the OFF position.
Brix Dispense Test Set Up Procedure
1. 1. Load the concentrate in the dispense station. Dispense until the finished drink is flowing from the dispense nozzle.
2. Dispense a typical cup size and discard.
3. Dispense another sample and measure the Brix using a refractometer. Best practice is to allow samples dispensed with
nitrogen to settle before taking a measurement.
• Once a sample is placed on the refractometer, wait until it reaches temperature to determine current Brix measurement
(about 1-2 minutes).
• Many refractometers include a thermometer on board and will help indicate that the sample is at room temperature and
ready to be tested. (See refractometer manual for more details on usage.)
4. To increase or decrease the product output, refer to Step 10 of SET-UP INSTRUCTIONS.
5. Continue making pump speed adjustments and measuring samples until desired Brix target is reached.
ADJUSTMENT & OPTIONAL SETTINGS (cont)
Dispenser Lockout
Dispense functions of the dispenser can be turned-off to prevent unauthorized use of the dispenser, while keeping
the refrigeration system running.
1. Locate the Dispense Lockout switch inside the door at the top of the dispenser.
2. Place the switch in the OFF position to prevent dispensing.
3. Place the switch in the ON position to allow dispensing.
NOTE: This switch will also operate the door lights on models equipped with this feature and actuates water bath
autofill.
54261.0001 090817
Ratio
Target
3 sec. water
dispense in
milliliters
4+1 5+1 6+1 7+1 8+1 9+1 10+1 11+1 12+1 13+1 14+1
133 33.3 26.6 22.2 19.0 16.6 14.8 13.3 12.1 11.1 10.2 9.5
15+1 16+1 17+1 18+1 19+1 20+1 21+1 22+1 23+1 24+1 25+1
133 8.9 8.3 7.8 7.4 7.0 6.7 6.3 6.0 5.8
5.5 5.3
26+1 27+1 28+1 29+1 30+1 31+1 32+1 33+1
133 5.1 4.9 4.8 4.6 4.4 4.3 4.2 4.0