Bunn LCA-2 LP Скачать руководство пользователя страница 25

25

Field Calibration of the Concentrate Pumps & Dispenser Flow Rates

(Continued)

4.  Stop dispensing and allow the tip to stop dripping. Discard the water collected

5.  Place a 1500 to 2000 ml graduated container under Left Dispense Tip.

6.  Press & Hold the Regular dispense switch. The dispenser will display a 20 second count down 

timer and then stop dispensing automatically. Release the dispense switch.

7.  Keep the graduated container under dispense tip until all the water stops dripping.

8.  Measure the volume of water collected in the graduated container.

The acceptable range for the volume of water collected is .95 - 1.12 liters

9.  If the amount of water collected is not within the acceptable range, empty the graduated con-

tainer and repeat STEPS 5 – 8.

10. If the amount collected is still not within range, inspect the dispense valves, tubing and mix 

chamber for lime, kinks or other obstructions.

11. When satisfied with the volume of water collected, press the MENU switch. The current Water 

Calibration volume “C3 XX” will be displayed. 

12. Use the (-) / (+) keys to adjust number displayed to the amount measured in STEP 8.

Decaffeinated Coffee - Dispenser Flow Rate Calibration

Depress the MENU switch to display the Decaffeinated Coffee Flow Rate calibration menu “C4 run”.

Repeat STEPS 3 – 12 above for the right side “Decaf” pump.

Field Calibrating the Empty Product Warning

The dispenser will automatically turn on the Regular or Decaf “REFILL LED”, see Operating Controls 

and Interface, when the corresponding container is Empty. The Refill message is triggered when the 

conductance sensor reading drops below the minimum setting. The factory set minimum is 600 and 

should be correct for most locations. However, in some areas the hardness of the local water supply 

may effect this reading. If the Refill message doesn’t come on when the container is empty or the mes-

sage comes on too early and there is still concentrate left in the container, use the following procedure 

to find the correct Empty Product Threshold.

Calibrating The Empty Product Threshold

1.  Open the dispenser door to access the digital programming module with LED display and set the 

Function Switch to the “Rinse” position. Leave the door open to view the LED display.

2.  Place a large container under the dispenser tip, then activate and hold the Regular Coffee dispense 

switch.

3.  Hold the dispense switch long enough to rinse all the concentrate out of the mix chamber and for 

the Conductance reading to stabilize and stop dropping.

4.  Record the nominal Conductance value displayed. (NOTE: It is typical for this value to fluctuate (+/- 

25) points about the nominal value.) This is the conductance reading of the water in your area.

5.  Repeat steps 2, 3 & 4 for the Decaf Coffee dispenser.

6.  Add 100 points to the larger of the Regular or Decaf conductance value. This is the new Empty 

Product threshold value for your dispenser.

7.  Enter this new value into the Empty Product Alarm threshold position “P8 XXX”, see Program-

ming the Dispenser.

38791 072307

Содержание LCA-2 LP

Страница 1: ...SPRINGFIELD ILLINOIS 62708 3227 PHONE 217 529 6601 FAX 217 529 6644 To ensure you have the latest revision of the Operating Manual or to view the Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way to obtain the latest catalog and manual updates For Technical Service contact Bunn O Matic C...

Страница 2: ... sole discretion that the equipment does not conform to the warranty BUNN at its exclusive option while the equipment is under warranty shall either 1 provide at no charge replacement parts and or labor during the applicable parts and labor warranty periods specified above to repair the defective components provided that this repair is done by a BUNN Authorized Service Representative or 2 shall re...

Страница 3: ...se Alarm Feature 11 Programming the Dispenser 12 Priming the Concentrate Lines 16 Draining the Hot Water 16 Operating the Dispenser 17 Cleaning Preventive Maintenance 18 Replacing the Pump Tubing 19 Calibrating the Dispenser 20 Troubleshooting Guide 22 Field Calibration of the Concentrate Pumps 24 Dispenser Flow Rate Calibration 24 Field Calibrating the Empty Product Warning 25 Schematic Wiring Di...

Страница 4: ...8791 060711 00824 0002 As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration FDA this equipment must be installed with adequate backflow prevention to comply with federal state and local codes For models installed outside the U S A you must comply with the applicable Plumb ing Sanitation Code for your area Artw...

Страница 5: ...unter top It can be purchased direct from Bunn O Matic part number 00326 0000 Bunn O Matic does not recommend the use of a saddle valve to install the dispenser The size and shape of the hole made in the supply line by this type of device may restrict water flow INTRODUCTION The Liquid Coffee Ambient Dispenser delivers two types of coffee made from liquid concentrate plus hot water The dispenser c...

Страница 6: ...nel a Insert the top tabs into the slots on the door panel b Align the key hole slots over the two lower screws then slide the splash guard down c Tighten the two lower screws 8 Level the dispenser using the adjustable feet on the legs 1 Securely attach the short piece of tubing and the water strainer assembly to the inlet fitting on the bottom of the dispenser 2 Flush the water line to remove any...

Страница 7: ... product concentrate and water 12 Mode Selector Switch Allows the user to select different operating modes a Run Normal operating position b Night Anti pilfering mode that disables dispensing but keeps heater and chiller operational WARNING The NIGHT Mode does not remove AC power from the dispenser Disconnect power source before servicing the dispenser c Program Enables programming and set up of t...

Страница 8: ...8 14 11 12 13 2 4 1 3 7 8 5 6 9 10 ...

Страница 9: ...ess the tension screw and insert it in the notch in the pump body reapplying spring tension on the pump band 6 Install the free end of the tube over the inlet port of the mix chamber on that side of the cabinet 7 Replace the tubing retainer plate and tighten the thumbscrew 8 Open the product container and insert the stainless steel drawtube into the container 9 Repeat steps 1 through 8 for the oth...

Страница 10: ... to the power source The Red POWER LED will illuminate and water will begin flowing into the tank The dispenser will automatically stop filling when the tank is full The dispenser will not begin heating the water until after the tank is filled 4 The Green READY LED will illuminate when the tank temperature reaches the preset ready temperature 3 4 1 38791 031606 ...

Страница 11: ...Rinse Alarm disabled No Alarm It is up to the user to determine the Rinse time interval and the level of warning required based on their application and maintenance procedures To enable the automated Rinse Alarm feature refer to RINSE ALARM in Programming the Dispenser Rinse Procedure 1 Open the cabinet door and select Rinse on the Function Selector switch close the door 2 Place a 2 Liter 1 2 Gal ...

Страница 12: ...to scroll to the next display NOTE The display blanks out after two minutes of inactivity Press any button to activate the display LCD DISPLAY DISPLAY MODE DESCRIPTION Home View DisplaysTank Temperature Tank Temperature Displays target Tank Temperature F Regular Dispense Ratio Displays Left Dispense Ratio XXX 1 Decaf Dispense Ratio Displays Right Dispense Ratio XXX 1 Cup Dispense Volume Displays C...

Страница 13: ...Exits To Home View After 3 Seconds LCD DISPLAY DISPLAY MODE DESCRIPTION Empty Product Threshold Displays Empty Product Threshold Default 600 PROGRAMMING THE DISPENSER Cont Display Mode Continued Rinse Alarm Hrs DisplaysTheHoursBetweenRequired Rinses Default 0 OFF Alarm Disabled 38791 040306 MENU 6 0 8 0 0 MENU O 0 9 F F MENU LC x x MENU 0 6 0 0 0 MENU 0 7 0 0 0 ...

Страница 14: ...Range 120 200 F Ready Temp Tank Temp minus 10 F LCD DISPLAY PROGRAM MODE DESCRIPTION Left Regular Dispense Ratio Set Regular Coffee Ratio Default 30 1 Range 25 Max 100 Min Right Decaf Dispense Ratio Set Decaf Coffee Ratio Default 30 1 Range 25 Max 100 Min Cup Dispense Volume Set Cup Dispense Volume Default 0 0 Push Hold Range 0 0 16 0 Oz Carafe Dispense Volume Set Carafe Dispense Volume Default 0 ...

Страница 15: ...switch then Right switch for 15 seconds each 38791 063009 MENU P 7 0 0 MENU P 8 6 0 0 MENU O P 9 F F MENU LC x x 0 Program Lockout Function The operator must hold down the stop and portion control button for 10 sec onds while machine is in program mode At 10 seconds the machine s display changes from PPP to PP LOC indicating the locked position At this point the operator may view the setup functio...

Страница 16: ...K CAUTION The dispenser must be disconnected from the power source throughout these steps 1 Disconnect the dispenser from the power source 2 Shut off and disconnect the incoming water supply 3 Remove the right side access panel 4 Pull out drain tube to empty into a sink or a container with a minimum of 200 ounce capacity 5 Make sure drain clamp is closed then remove drain plug 6 Direct tube into s...

Страница 17: ... of the cycle c Remove cup 2 Carafe Dispense Mode Refer to Programming Functions to set this volume a Place the appropriate size container beneath the dispensing tip b Momentarily press the Portion Switch The Portion LED will illuminate for 5 seconds after the Portion Switch is pressed c Momentarily press the desired dispense switch If the user waits longer than 5 seconds to push the switch the di...

Страница 18: ...ugh the connector Note Cutting the mating fittings from an empty bag makes an excellent free flowing connector for this purpose 3 Place bag connector into a one gallon 3 8 liter container of warm soapy tap water 140F 60C 4 Place an empty container under dispense tip and activate corresponding Dispense Switch until clean soapy water is dispensed from the dispense tip 5 Repeat steps 3 and 4 with war...

Страница 19: ...iddle section of the new pump tubing Fig 4 6 Carefully wrap the new tubing around the rotor making sure that the elbow and clamps end up on the front side of the pump body Fig 5 7 Depress the tension screw and insert it in the notch in the pump body reapplying spring tension on the pump band 8 Install the free end of the tube over the inlet port of the mix chamber on that side of the cabinet Fig 5...

Страница 20: ...collected from the 20 sec test above Default 22 Range 18 26mL Right Decaf Pump Cal SetPRIME NORMAL RINSEswitchto PRIME position Press and hold Decaf Dispense Switch until pump stops 20 sec Refer to Field Calibration of the Concentrate Pumps Right Decaf Pump Cal Enter mL collected from the 20 sec test above Default 22 Range 18 26mL Left Regular Water Rate SetPRIME NORMAL RINSEswitchto RINSEposition...

Страница 21: ... Delay Delays the Pump turn off after a dispense Default 200 Range 1 999 mSec Reset Factory Defaults Resets all set up values to the Factory Default setting Hold both Increase and Decrease switch for 10 seconds Displays Software Version Exits To Home View After 3 Seconds English or Metric Mode Eng for English S I for Metric Error Code History Displays last known Error Code Depress the Decrease to ...

Страница 22: ...ng the troubleshooting steps contact the Bunn O Matic Technical Service Department Left Regular Pump Failed Left Motor or RPM Sensor Failure Check motor and RPM sensor wires for shorts or open connections Right Decaf Pump Failed Right Motor or RPM Sensor Failure Check motor and RPM sensor wires for shorts or open connections Heating Time Too Long Tank Heater ON Continuous For More Than 1 Hour Chec...

Страница 23: ...oard Failure Unable To Communicate With The Switch Board In The Door Faulty wiring between the Door and the Main Control Board 38791 040306 Power Supply Voltage Out of Range Too High 26 Vdc or Too Low 23 Vdc Display alternates between EC 011 and the actual power supply voltage XX Vdc Check line voltage Check 115 230 Vac switch on the power supply MENU 7 C E 0 0 MENU 0 C E 0 1 MENU 1 C E 0 1 ...

Страница 24: ...er under the Left Dispense Tip 7 Press Hold the Regular dispense switch The dispenser will display a 20 second count down timer and then shut the pump OFF automatically Release the dispense switch 8 Keep the graduated cylinder under dispense tip until all the concentrate has dripped out 9 Measure the volume of concentrate collected in the graduated cylinder The acceptable range for the volume of c...

Страница 25: ...on the Regular or Decaf REFILL LED see Operating Controls and Interface when the corresponding container is Empty The Refill message is triggered when the conductance sensor reading drops below the minimum setting The factory set minimum is 600 and should be correct for most locations However in some areas the hardness of the local water supply may effect this reading If the Refill message doesn t...

Страница 26: ...LK 18 BLK 18 WHT 18 J4 10 MAIN CONTROL BOARD YEL 18 ORN 18 RED 18 J4 1 J4 5 N O COM BLK 16 RINSE WHT VIO 22 J8 5 WHT GRAY 22 WHT BLK 22 GRAY 22 BRN 20 RED 20 J8 10 J8 14 J8 1 BLK 22 VIO 22 BRN 20 RED 20 PROGRAM NIGHT RUN NORMAL PRIME LEFT CONDUCTANCE RIGHT CONDUCTANCE ORN 22 PINK 22 J10 1 J10 4 GRN 22 WHT ORN 22 GRAY 18 GRAY 18 J2 5 J2 8 J2 1 WHT 18 RED 18 BLK 18 RED 18 1 WHT BLK t N L2 BLK 18 WHT...

Отзывы: