Bunn HWB Скачать руководство пользователя страница 5

5

PLUMBING REQUIREMENTS

This dispenser must be connected to a COLD WATER system with operating pressure between 20 and 100 psi 

(0.138 and 0.690 MPa). This water source must be capable of producing a minimum flow rate of 4.5 fl. oz. 

(133.1 ml) per second.  A shut-off valve should be installed in the line before the dispenser.  Install a regulator in 

the line when pressure is greater than 100 psi (0.690 MPa) to reduce it to 50 psi (0.345 MPa).  The water inlet 

fitting is .38” (9.52 mm) flare.

NOTE - Bunn-O-Matic recommends 1⁄4” copper tubing for installations of less than 25 feet and 3⁄8” for more 

than 25 feet from the 1⁄2” water supply line.  At least 18 inches of an FDA approved flexible beverage tubing, 

such as reinforced braided polyethylene or silicone, before the dispenser will facilitate movement to clean the 

countertop.  Bunn-O-Matic does not recommend the use of a saddle valve to install the dispenser.  The size and 

shape of the hole made in the supply line by this type of device may restrict water flow.

NOTE - If a backflow preventer is required by code, a shock arrestor should be installed between backflow pre-

venter and dispenser. Installing the shock arrestor as close to the dispenser as possible will provide the best 

results.

NOTE - Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed 

and maintained in accordance with federal, state and local codes.

PLUMBING HOOK-UP

1.  Flush the water line and securely attach it to the elbow fitting on the back of the dispenser.

2.  Turn on the water supply.

INITIAL FILL & HEAT

1.   Turn on the water supply and connect the dispenser to the power source.

2.  Open the front door and place the ON/OFF/NIGHT switch in the “ON” (upper) position.

3.  Turn main power switch “ON”. Water will automatically flow into the tank to the proper level and then shut-

off.  This will take less than ten minutes.

4.  Fill the hopper(s) with the dry product to be dispensed.

LIQUID LEVEL CONTROL

The system automatically maintains the hot water tank’s level by energizing the refill solenoid when the water 

level drops below the liquid level probe. If the system has not successfully refilled in 10 minutes, a refill error 

occurs. When a refill error occurs, the refill solenoid is de-energized. Once the cause of the refill error has been 

investigated and cured, the system can be reset by either turning main power off 5 seconds then turning on, or 

unplugging for 5 seconds, or by entering one of the program modes (see Programming, page 17.)

As directed in the International Plumbing Code of the International Code Council and the Food 

Code Manual of the Food and Drug Administration (FDA), this equipment must be installed with 

adequate backflow prevention to comply with federal, state and local codes. For models installed 

outside the U.S.A., you must comply with the applicable Plumbing /Sanitation Code for your area.

45398.2 111315

Содержание HWB

Страница 1: ...revision of the Operating Manual or to view the Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way to obtain the latest catalog and manual updates For Technical Service contact Bunn O Matic Corporation at 1 800 286 6070 45398 0002A 11 15 2015 Bunn O Matic Corporation ...

Страница 2: ...tements by such individuals whether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive op tion while the equipment is under warranty shall either 1 provide at no charge replacement parts and or labor during the applicable parts and labor warranty periods speci...

Страница 3: ...lumb ing Sanitation Code for your area Artwork for P N 00656 0001 Artwork Rev A Drawn REF Date 04 22 10 USER NOTICES The notices on this dispenser should be kept in good condition Replace unreadable or damaged labels 00831 0000 00656 0001 To reduce the risk of electric shock do not remove or open cover No user serviceable parts inside Authorized service personnel only Disconnect power before servi...

Страница 4: ...l not be tilted more than 10 for safe operation An electrician must provide electrical service as specified in conformance with all local and national codes This appliance must not be cleaned by pressure washer This appliance can be used by persons aged from 18 years and above if they have been given supervision or instruction concerning use of the appliance in a safe way and if they understand th...

Страница 5: ...ed and maintained in accordance with federal state and local codes PLUMBING HOOK UP 1 Flush the water line and securely attach it to the elbow fitting on the back of the dispenser 2 Turn on the water supply INITIAL FILL HEAT 1 Turn on the water supply and connect the dispenser to the power source 2 Open the front door and place the ON OFF NIGHT switch in the ON upper position 3 Turn main power swi...

Страница 6: ...hat button then select a drink size for that product of choice within 3 seconds 4 Let the mixing chamber completely drain before removing cup DISPENSE HOT WATER Portion Control 1 Place cup under hot water dispensing tip 2 Press momentarily and release hot water button then appropriate size for portion control within 3 seconds Or Press the hot water button a second time and release when desired vol...

Страница 7: ...de salida de cada tolva deberá realizarse diariamente 1 x 7d 1 2 3 4 5 a Wash b Rinse c Sanitize d Dry a Lave b Enjuague c Desinfecte d Seque 7 8 6 a b c d 9 7 1 Para limpiar las camaras de mezcla coloque el interruptor en la posicón NORMAL PROGRAMACIÓN ENJUAGUE NORMAL PROGRAM RINSE y pulse el boton para espumar y distribuir la bebida DISPENSE 2 Gire el codo hacia arriba remueva las tolvas llene l...

Страница 8: ... 1 PRESS DISPENSE 5 Press HOT WATER button until Cal Water X where X is head to be calibrated 6 Place container under dispense head being tested Then press and release membrane dispense but ton for the dispense head being tested 7 The unit will automatically dispense for ten sec onds 8 Press HOT WATER button the screen should change to Enter Volume Enter the volume of water captured in graduated c...

Страница 9: ...e for ten seconds Run one cycle but do not use results this primes sys tem 12 Press HOT WATER button the screen should change to Enter Weight X where X is head to be calibrated Then weigh the catch cup with powder and enter the weight in grams Use a 5 run av erage 13 Repeat for all stations 14 Return Program switch to Normal 15 Two large dispenses are required for auger mo tors to adjust if new ca...

Страница 10: ...ent product The hopper must be at least half full of product for calibration Place the NORMAL PROGRAM RINSE switch in the PROGRAM position Using HOT WATER button forward until the CALIBRATION menu is reached Press REDUCED FILL button for YES then press HOT WATER button until CAL HOPPER 1 LPD screen is reached Continue to press button A until the hopper to be calibrated is reached To calibrate the ...

Страница 11: ... toggle switches located to the right of the head 5 whipper chamber to their top positions NORMAL and ON respectively 2 Remove the black USB port protective plug from between the two toggle switch es and insert the desired USB Flash Drive into the port 3 Wait approximately five to ten seconds if you have an LED on your flash drive it should light up now and then remove the USB flash drive from the...

Страница 12: ...n the machine 9 Wait about five seconds for the thumb drive to pair up then flip the top most toggle switch inside the ma chine to the middle position this will be the PROGRAM position making sure that the bottom toggle switch is in the top position this is the ON position 10 Close the door on the HWB machine The 2x16 display should now say the follow ing PROGRAM MODE PRESS FORWARD SW 11 Press and...

Страница 13: ...may take up to two minutes for the reprogramming process to complete During this time the machine will appear unresponsive and if your USB Flash Drive has an indicator LED on it it should be actively blinking to indicate that the reprogramming activity is occurring 17 When the software update has successfully completed the machine should show the new software version number briefly on the screen a...

Страница 14: ...ou are loading to ensure that they are properly installed set up and functional 20 Once the reprogramming has completed successfully remove the flash drive from the HWB machine place both toggle switches in the upper most positions again NORMAL and ON and the machine should be ready to return to normal operation NOTICE Once you have the proper directory structure on your USB Flash Drive you can st...

Страница 15: ...write old data if no flash drive is present and over 300 faults have been logged When exporting drink counts drink history and fault history one backup file is created on the USB drive bak Drink History key Drink 1 Head 1 2 Head 2 3 Head 3 4 Head 4 5 Head 5 6 Hot Water 91 Rinse Head 1 92 Rinse Head 2 93 Rinse Head 3 94 Rinse Head 4 95 Rinse Head 5 Size 0 Null 1 Small 2 Medium 3 Large 4 X large 5 B...

Страница 16: ...pper motors DISPLAY USAGE EXIT YES Displays amount dispensed ENABLE SERVICE NO EXIT YES GLOSSARY FACTORY DEFAULTS NO YES Resets all functions to factory defaults and password to 0 DISABLE MESSAGES NO EXIT YES Disables function that displays fault messages on LCD door display SET CUP SIZE EXMPL TIME Select setting cup size by Time seconds or by Example DISPENSE TO ADD REPEAT SAVE Press same dispens...

Страница 17: ...d the display will return to the PRO GRAM HOME SCREEN Using the menu driven display MAIN SCREEN on the front of dispenser the operator has the ability to alter or modify various functions of the dispenser This allows for precise dispensing of various flavors of powdered products Programming of dispenser is achieved by entering a certain function then by use of programming switch es the operator ca...

Страница 18: ... move to the next menu If Hidden button was selected to exit the program mode return the NORMAL PROGRAM RINSE switch to the NORMAL position to return to nomal operation If recipes have been added to the machine cup sizes and ratio can also be adjusted by changing the recipe Place the NORMAL PROGRAM RINSE switch in the PROGRAM position Press HOT WATER button until screen SET CUP SIZE BY EXAMPLE TIM...

Страница 19: ...O EXIT YES ENABLE ADS NO EXIT YES ENTER ASSET EXIT YES ENABLE SERVICE NO EXIT YES DIAGNOSTICS EXIT YES DISPLAY USAGE EXIT YES FACTORY DEFAULTS NO YES A continue to B page 20 C continue to D page 20 E G I FINISHED returns to main screen K M Adjust tank temperature Adjust minimum tank ready temperature for lockout continue to L page 22 continue to J page 22 O continue to N page 17 ENTER USB MENU VIE...

Страница 20: ...REFILL 155 EXIT CAL WATER 1 PRESS DISPENSE ENTER VOLUME 1 XX X oz CAL POWDER 1 PRESS DISPENSE ENTER WEIGHT 1 XX X gm AUGER DELAY CAL HOT WATER XX sec PRESS TO DISPENSE HOPPER 1 FULL CAL HOPPER 1 LPD NO YES NO YES Returns to E page 19 Goes to next station Returns to A page 19 after last station Goes to next station Continues after last station Goes to next station Continues after last station Goes ...

Страница 21: ...eturns to G page 19 H F 45398 2 111315 REPRGM IMIXHWBO EXIT YES REPROGRAM USB EXPORT DRINK CNT EXPORT DRINK HST IMPORT RECIPES ODOMETER STOPPED DISPENSE HOT WATER COUNTS SELECT A PORTION RINSE COUNTS RESET COUNTERS EXIT YES EXIT YES EXIT YES EXIT YES XXXXX COUNTS XXXX SELECT A SIZE TO VIEW COUNTS SELECT A HEAD NO EXIT YES ...

Страница 22: ...page 19 TEST SWITCHES Use Switch To Test TEST HEATER EXIT YES TEST REFILL EXIT YES TEST HOT WATER EXIT YES TEST AUGERS DISPENSE TO TEST TEST DISPENSE HEAD DISPENSE TO TEST Returns to M page 19 J L RINSE ALARM TIME XX hours RINSE LOCKOUT NO EXIT YES Goes to next station Continues after last station PROGRAMMING THE DISPENSER cont 45398 2 111315 ...

Страница 23: ...any BOX O JOE portion size dispense NOTE If the BOX O JOE dispense time exceeds 2 minutes with the pulses added in it will throw a dispense too long fault Press and release any dispense button to set cup size PROGRAMMING THE DISPENSER cont Returns to O page 19 Returns to O page 19 Goes to next station HEAD 1 XLG TIME 18 0 SEC HEAD 1 BOX TIME 38 0 SEC After last station SMALL SHORT SMALL H W TIME 8...