36
SERVICE (cont.)
FIG. 32 DISPENSE SOLENOID VALVE
TERMINALS
P1672
Removal and Replacement:
1. Remove the four #8-32 screws securing the side
access panel to the housing. Remove panel and
set aside.
2. Remove the wires from the solenoid valve.
3. Turn-off the water supply to the dispenser.
4. Using the tank drain tube, drain enough water from
the tank so the water level is below the dispense
valve mounting hole.
5. Disconnect the water line from the solenoid
valve.
6. Remove the #8-32 keps nut securing the solenoid
valve bracket to side of the tank. Remove solenoid
valve.
7. Install new solenoid valve and o-ring on side of
the tank and secure in place with valve mounting
bracket and #8-32 keps nut.
8. Push the water line onto the tube on bottom of
solenoid valve.
9. Refer to Fig. 32 and reconnect the wires.
10. Reinstall side access panels.
SOLENOID VALVE (DISPENSE) - FMD-4 & FMD-5
(cont.)
WHIto Main Harness
TAN to Main Harness Station #1
RED to Main Harness Station #2
ORN to Main Harness Station #3
YEL to Main Harness Station #4
BLU to Main Harness Station #5
35135 012103
Содержание FMD-4