9
TROUBLESHOOTING (cont.)
PROBLEM
Dripping from dispense tip
Water flows into tank continuously
Product overflows container
PROBABLE CAUSE
1. Lime build-up
CAUTION -
Tank and tank compo-
nents should be delimed regularly
depending on local water conditions.
Excessive mineral build-up on stain-
less steel surfaces can initiate corro-
sive reactions resulting in serious
leaks.
2. Dispense solenoid valve (Hot or
Cold)
1. Level control board and probe
2. Solenoid valve (Inlet)
3. Overflow Protection Switch
1. Dispense switch
2. Dispense solenoid valve (Hot or
Cold)
REMEDY
Inspect the tank assembly for exces-
sive lime deposits. Delime as re-
quired.
Remove the dispense solenoid valve
and clear any obstructions. Rebuild
or replace the valve if necessary. See
page 29 or 30
Refer to
Service - Level Control Board
and Probe for testing procedures.
See page 24
Refer to
Service - Solenoid Valve
(Inlet) for testing procedures. See
page 31
Refer to
Service - Overflow Protec-
tion Switch for testing procedures.
See page 27
Refer to
Service - Dispense Switch
for testing procedures. See page 17
Remove the solenoid valve and clear
any obstructions. Rebuild or replace
the valve if necessary. See page 29
or 30
28364 011598