![Bunn CWTF-APS-MV Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/bunn/cwtf-aps-mv/cwtf-aps-mv_operating-and-service-manual_2830901009.webp)
Page 9
TROUBLESHOOTING (cont.)
PROBLEM
Brew cycle will not start (cont.)
Water is not hot
PROBABLE CAUSE
REMEDY
5. Timer
6. Solenoid Valve
7. Water strainer/flow control
(.222 GPM)
1. Tank Heater Switch
2. Limit Thermostat
CAUTION -
Do not eliminate or
bypass limit thermostat. Use only
replacement part #29329.1000
3. Control Thermostat
4. Tank Heater(s)
5. Fuse Holder and Fuse Assembly
6. Thermal Fuse
Refer to
Service - Timer for testing
procedures. See page 26 or 27
Refer to
Service - Solenoid Valve
for testing procedures. See page
19
(A) Direction of flow arrow must
be pointing towards brewer.
(B) Remove the strainer/flow con-
trol and check for obstructions.
Clear or replace.
Refer to
Service - Tank Heater
Switch for testing procedures. See
page 23
Refer to
Service - Limit Thermo-
stat for testing procedures. See
page 17
Refer to
Service - Control Ther-
mostat for testing procedures. See
page 15
Refer to
Service - Tank Heater(s)
for testing procedures. See page
21
Refer to
Service -Fuse Holder and
Fuse Assembly for testing proce-
dures. See page 16
Refer to
Service - Thermal Fuse
for testing procedures. See page
25
28182 090100