INTRODUCTION

This equipment supplies a liquid concentrate mixed with water at various ratios to the  hoppers on the dispens-

ers.  It is for indoor use only on a sturdy counter or shelf.

USER NOTICES

Carefully read and follow all notices on the equipment and in this manual.  They were written for your protection. 

All notices are to be kept in good condition.  Replace any unreadable or damaged labels.

00656.0001

00986.0002

As directed in the International Plumbing Code of the 

International Code Council and the Food Code 

Manual of the Food and Drug Administration (FDA), 

this equipment must be installed with adequate 

backflow prevention to comply with federal, state 

and local codes. For models installed outside the 

U.S.A., you must comply with the applicable Plumb-

ing /Sanitation Code for your area.

Artwork for P/N:  00656.0001
Artwork Rev:  A
Drawn:  REF
Date:  04/22/10

37881.0000

ELECTRICAL REQUIREMENTS

CAUTION - The dispenser must be disconnected from the power source until specified in Initial Set-Up.

The 120 volt version of this dispenser has an attached cordset and requires 2-wire, grounded service rated 120 

volts ac, 15 amp, single phase, 60 Hz.  The mating connector must be a NEMA 5-15R.

The 230 volt CE version requires 2 wire, grounded service rated 230V ac, single phase, 50 Hz.

The 200 volt or 240 volt versions require 2 wire, grounded service rated 200 volts ac or 240 volts ac, single 

phase, 50 Hz.

(Refer to the dispenser’s data plate for exact voltage requirement.)

00824.0002

CE REQUIREMENTS

• This appliance must be installed in locations where it can be overseen by trained personnel.

• For proper operation, this appliance must be installed where the temperature is between 5°C to 35°C.

• Appliance shall not be tilted more than 10° for safe operation.

• An electrician must provide electrical service as specified in conformance with all local and national codes.

• This appliance must not be cleaned by water jet.

• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless they have been given instructions concerning use of 

this appliance by a person responsible for its safety.

• Children should be supervised to ensure they do not play with the appliance.

• If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service personnel 

with a special cord available from the manufacturer or its authorized service personnel in order to avoid a hazard.

• Machine must not be immersed for cleaning.

Содержание AFPO-2

Страница 1: ...DE BUNN O MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD ILLINOIS 62708 3227 PHONE 217 529 6601 FAX 217 529 6644 To ensure you have the latest revision of the Operating Manual or to view the Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way to obtain the latest catalog and manual upd...

Страница 2: ... sole discretion that the equipment does not conform to the warranty BUNN at its exclusive option while the equipment is under warranty shall either 1 provide at no charge replacement parts and or labor during the applicable parts and labor warranty periods specified above to repair the defective components provided that this repair is done by a BUNN Authorized Service Representative or 2 shall re...

Страница 3: ...ng connector must be a NEMA 5 15R The 230 volt CE version requires 2 wire grounded service rated 230V ac single phase 50 Hz The 200 volt or 240 volt versions require 2 wire grounded service rated 200 volts ac or 240 volts ac single phase 50 Hz Refer to the dispenser s data plate for exact voltage requirement 00824 0002 CE REQUIREMENTS This appliance must be installed in locations where it can be o...

Страница 4: ...This refill unit should not be used to initially fill the hopper Running the motor for extended periods will trip the thermal switch The thermal switch will reset but requires up to 30 minutes of cooling time NOTE Hoses and product container connectors are not supplied Fitting clamps and labels are supplied Make hose assemblies as required Refer to PIPING DIAGRAM on page 23 1 Assemble hoppers with...

Страница 5: ...ning solution consisting of 1 gallon of hot water and a sanitizing cleaner which contains 3 5 chlorine based sanitizer Mix per manufacturers instructions 2 Remove connectors from each concentrate container and place them directly into the cleaning solution 3 Energize each refill station and allow the cleaning solution to pump through the system into the hoppers The cleaning procedure should remove...

Страница 6: ...e test hose press the corresponding TEST OUTPUT switch and carefully measure and note the elapsed time from when the product first flows from the test hose to when one half cup of the product has been dispensed This value may then be used in the formula below Following flavor pump output measurement disconnect the flavor line from the FLAVOR INPUT and purge remaining product from the line Formula ...

Страница 7: ...PERATE switch is located inside the auto fill box just below the top access cover For setting flow rates and mix ratios for flavors place the TEST OPER ATE switch in the TEST position This allows the op erator to run the water and flavor lines for each circuit depending on the requirements for the flavor recipe D PROBE CONTROL BOX LOW OFF HIGH On models equipped with a dual level probe there is a ...

Страница 8: ...ifference between the AFPO 2 3 and AFPO 2 3 SL is the SL models have a water output line and a flavor output line for each product This allows the water and flavor to be mixed in the hoppers Refer to the illustration below when connecting the lines ...

Отзывы: