background image

AFPO-2

AFPO-2 SL

AFPO-3

AFPO-3 SL

 

FLA

VOR

INP

UT

1  

 

2

WA

TER

INP

UT

REF

ILL

MA

IN

PO

WE

R

2

1

1

2

3

3

3

FLA

VO

R

OU

TPU

T

FLA

VO

R

OU

TPU

T

WA

TER

OU

TPU

T

FLA

VO

R

OU

TPU

T

WA

TER

OU

TPU

T

WA

TER

OU

TPU

T

FLA

VOR

INP

UT

1  

 

2

WA

TER

INP

UT

FLA

VO

R

OU

TPU

T

FLA

VO

R

OU

TPU

T

WA

TER

OU

TPU

T

WA

TER

OU

TPU

T

REF

ILL

MA

IN

PO

WE

R

2

1

1

2

INSTALLATION & OPERATING GUIDE

BUNN-O-MATIC CORPORATION

POST OFFICE BOX 3227

SPRINGFIELD, ILLINOIS 62708-3227

PHONE: (217) 529-6601    FAX: (217) 529-6644

To ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts 

Catalog, Programming Manual, or Service Manual, please visit the Bunn-O-Matic website, at    

www.bunn.com. This is absolutely FREE, and the quickest way to obtain the latest catalog and 

manual updates. For Technical Service, contact Bunn-O-Matic Corporation at 1-800-286-6070.

28791.0000K   07/11   ©1998 Bunn-O-Matic Corporation

Содержание AFPO-2

Страница 1: ...DE BUNN O MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD ILLINOIS 62708 3227 PHONE 217 529 6601 FAX 217 529 6644 To ensure you have the latest revision of the Operating Manual or to view the Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way to obtain the latest catalog and manual upd...

Страница 2: ... sole discretion that the equipment does not conform to the warranty BUNN at its exclusive option while the equipment is under warranty shall either 1 provide at no charge replacement parts and or labor during the applicable parts and labor warranty periods specified above to repair the defective components provided that this repair is done by a BUNN Authorized Service Representative or 2 shall re...

Страница 3: ...ng connector must be a NEMA 5 15R The 230 volt CE version requires 2 wire grounded service rated 230V ac single phase 50 Hz The 200 volt or 240 volt versions require 2 wire grounded service rated 200 volts ac or 240 volts ac single phase 50 Hz Refer to the dispenser s data plate for exact voltage requirement 00824 0002 CE REQUIREMENTS This appliance must be installed in locations where it can be o...

Страница 4: ...This refill unit should not be used to initially fill the hopper Running the motor for extended periods will trip the thermal switch The thermal switch will reset but requires up to 30 minutes of cooling time NOTE Hoses and product container connectors are not supplied Fitting clamps and labels are supplied Make hose assemblies as required Refer to PIPING DIAGRAM on page 23 1 Assemble hoppers with...

Страница 5: ...ning solution consisting of 1 gallon of hot water and a sanitizing cleaner which contains 3 5 chlorine based sanitizer Mix per manufacturers instructions 2 Remove connectors from each concentrate container and place them directly into the cleaning solution 3 Energize each refill station and allow the cleaning solution to pump through the system into the hoppers The cleaning procedure should remove...

Страница 6: ...e test hose press the corresponding TEST OUTPUT switch and carefully measure and note the elapsed time from when the product first flows from the test hose to when one half cup of the product has been dispensed This value may then be used in the formula below Following flavor pump output measurement disconnect the flavor line from the FLAVOR INPUT and purge remaining product from the line Formula ...

Страница 7: ...PERATE switch is located inside the auto fill box just below the top access cover For setting flow rates and mix ratios for flavors place the TEST OPER ATE switch in the TEST position This allows the op erator to run the water and flavor lines for each circuit depending on the requirements for the flavor recipe D PROBE CONTROL BOX LOW OFF HIGH On models equipped with a dual level probe there is a ...

Страница 8: ...ifference between the AFPO 2 3 and AFPO 2 3 SL is the SL models have a water output line and a flavor output line for each product This allows the water and flavor to be mixed in the hoppers Refer to the illustration below when connecting the lines ...