SERVICE (cont.)

VACUUM/SUPPLY PUMP TUBE INSTALLATION

1.  Separate the pump head from the pump body. 

Hold pump head as shown in Fig. 18, with roller 

in the  2, 6 10 o’clock positions.

2.  Wrap tubing around rollers and hold as shown in 

Fig. 18.

3.  Insert the slot of the tubing key (supplied), as 

shown in Fig. 18 on the rotor so the bottom edge 

of the key is pressing the tubing into the pump 

head cavity.

4.  Push down and turn the key counterclockwise to 

guide the tubing deep into the pump head cavity 

as shown in Fig. 19.

5.  Hold the tubing and rotor in the pump head and 

remove key carefully.

6.  Place pump body on the rotor shaft.

7.  Squeeze the pump body and pump head together 

simultaneously until pump body and pump head 

are touching on all sides. Be careful not to pinch 

the tubing between the pump body and the pump 

head.

FIG. 18  TUBING START POSITION

P1542

ROLLERS

PUMP

HEAD

TUBING

KEY

ENTRY

PORT

EXIT

PORT

FIG. 19 TUBING LOADED

ROTOR

ROTOR

SHAFT

P1541

28791.1 011500

Содержание AF PR-2

Страница 1: ...CORPORATION POST OFFICE BOX 3227 SPRINGFIELD ILLINOIS 62708 3227 PHONE 217 529 6601 FAX 217 529 6644 28791 0001B 1 00 1998 Bunn O Matic Corporation AF PR 2 AF PR 3 AFPR 3 VERSION DISCONTINUED The info...

Страница 2: ...cations to this warranty or to make additional warranties that are binding on Bunn Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be rel...

Страница 3: ...switches high level low level and a center OFF position 7 Place the main ON OFF switch and ON OFF refill switches in the OFF position 8 Make sure all hoses are connected Connect the dispenser to the...

Страница 4: ...y TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered If the problem remains after exhausting the troubleshooting steps...

Страница 5: ...the main power switch These allow each circuit to operate independently of the other P2052 C PROBE CONTROL BOX LOW OFF HIGH On models equipped with a dual level probe there is a LOW OFF HIGH switch l...

Страница 6: ...Fuse Holder for test procedures See page 8 Refer to Service Main ON OFF Switch for testing procedure See page 9 Refer to Service Probe System See page 10 Refer to Service Circuit Board for testing pro...

Страница 7: ...es to plug in the dispenser COMPONENT ACCESS WARNING Disconnect the dispenser from the power source before the removal of any panel or the replace ment of any component All components are accessible b...

Страница 8: ...BOARD P1556 O F F O N O F F O N O F F O N SERVICE Location The circuit board is located inside the autofill box mounted on the right side of the vacuum switch mounting Test Procedure 1 Disconnect the...

Страница 9: ...lace the fuse 28791 1 011500 BLK from Main Wiring Harness BLK to Main ON OFF Switch FIG 5 FUSE HOLDER TERMINALS P1331 Removal and Replacement Fuse 1 Remove the cap from the fuse holder 2 Removefusefro...

Страница 10: ...o the main ON OFF switch Disconnect the white wire from pump 1 3 Check for voltage across the black wires removed from the switch and the white wire removed from pump 1 Connect the dispenser to the po...

Страница 11: ...oss the signal cable pins see Fig 8A 6 If readings match values indicated the probe system electrically is functioning properly If not check the probe boxes 5 With the probe box switch in the LOW posi...

Страница 12: ...diagrams and check the dispenser wiring harness 5 Check for continuity across the switch terminals with the switch in the ON position Continuity must not be present when the switch is in the OFF posi...

Страница 13: ...from the pump leads 2 Disconnect the input and output tubes 3 Removethefourthumbscrewssecuringthepump head to the pump body discard pump head with tubes 4 Remove the two 8 32 keps nuts securing the pu...

Страница 14: ...p head cavity 4 Push down and turn the key counterclockwise to guide the tubing deep into the pump head cavity as shown in Fig 19 5 Hold the tubing and rotor in the pump head and remove key carefully...

Страница 15: ...32 keps nuts securing the pump and bracket to main panel 5 Disconnect the yellow and white wires from the pump 6 Remove pump and bracket as an assembly 7 Disconnecttheinputtubesfromthevacuumswitch to...

Страница 16: ...16 28791 1 011500...

Страница 17: ...17 28791 1 011500...

Отзывы: