Bunn 34000.0013 Скачать руководство пользователя страница 2

2

41047 031314

BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY

Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:

1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCR/MCP/MCA single cup brewers, ther-

mal servers and ThermoFresh® servers (mechanical and digital) 1 year parts and 1 year labor.

2) All other equipment - 2 years parts and 1 year labor plus added warranties as specified below:

a) Electronic circuit and/or control boards - parts and labor for 3 years.

b) Compressors on refrigeration equipment - 5 years parts and 1 year labor.

c) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis -  parts and 

labor for 4 years or 40,000 pounds of coffee, whichever comes first.

These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be 

commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the 

applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured 

by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect, alteration, improper installation or operation, 

improper maintenance or repair, non periodic cleaning and descaling, equipment failures related to poor water quality, 

damage or casualty. In addition, the warranty does not apply to replacement of items subject to normal use including but 

not limited to user replaceable parts such as seals and gaskets. This warranty is conditioned on the Buyer 1) giving BUNN 

prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Office Box

3227, Springfield, Illinois 62708-3227; 2) if requested by BUNN, shipping the defective equipment prepaid to an authorized 

BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under warranty.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EX-

PRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY 

OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make 

modifications to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such 

individuals, whether oral or written, do not constitute warranties and should not be relied upon.

If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive op-

tion while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during the 

applicable parts and labor warranty periods specified above) to repair the defective components, provided that this repair 

is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase price for 

the equipment.

THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS 

EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION 

AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND.

In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of 

use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities 

or services, or any other special, incidental or consequential damages.

392, A Partner You Can Count On, Air Infusion, AutoPOD, AXIOM, BrewLOGIC, BrewMETER, Brew Better Not Bitter, Brew-

WISE, BrewWIZARD, BUNN Espress, BUNN Family Gourmet, BUNN Gourmet, BUNN Pour-O-Matic, BUNN, BUNN with 

the stylized red line, BUNNlink, Bunn-OMatic, Bunn-O-Matic, BUNNserve, BUNNSERVE with the stylized wrench design, 

Cool Froth, DBC, Dr. Brew stylized Dr. design, Dual, Easy Pour, EasyClear, EasyGard,  FlavorGard, Gourmet Ice, Gourmet 

Juice, High Intensity, iMIX, Infusion Series, Intellisteam, My Café, Phase Brew, PowerLogic, Quality Beverage Equipment 

Worldwide, Respect Earth, Respect Earth with the stylized leaf and coffee cherry design, Safety-Fresh, savemycoffee.com, 

Scale-Pro, Silver Series, Single, Smart Funnel, Smart Hopper, SmartWAVE, Soft Heat, SplashGard, The Mark of Quality in 

Beverage Equipment Worldwide, ThermoFresh, Titan, trifecta, TRIFECTA (sylized logo), Velocity Brew, Air Brew, Beverage 

Bar Creator, Beverage Profit Calculator, Brew better, not bitter., Build-A-Drink, BUNNSource, Coffee At Its Best, Cyclonic 

Heating System, Daypart, Digital Brewer Control, Element, Milk Texturing Fusion, Nothing Brews Like a BUNN, Picture 

Prompted Cleaning, Pouring Profits, Signature Series, Sure Tamp, Tea At Its Best, The Horizontal Red Line, Ultra are either 

trademarks or registered trademarks of Bunn-O-Matic Corporation. The commercial trifecta® brewer housing configura-

tion is a trademark of Bunn-O-Matic Corporation.

Содержание 34000.0013

Страница 1: ...18 2008 Bunn O Matic Corporation To ensure you have the latest revision of the Operating Manual Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way to obtain the latest catalog and manual updates For Technical Service contact Bunn O Matic Corporation at 1 800 286 6070 ...

Страница 2: ...ements by such individuals whether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive op tion while the equipment is under warranty shall either 1 provide at no charge replacement parts and or labor during the applicable parts and labor warranty periods specif...

Страница 3: ...ramming the Dispenser 7 Function Index 7 Cleaning Guide 9 Set Consistency 10 Test Augers 11 Set Time Date 11 Password 12 Set Language 12 Set Night Day Time 13 Preventive Maintenance 14 Days to Clean 15 Consistency Adjust Lock 16 Switches Enabled 16 Delayed Refill 17 Refill Threshold 18 Ad Message Enabled 19 Service Phone 20 Enter Asset Number 21 Set Password 21 Service Tools 22 Restore Defaults 23...

Страница 4: ...GER ON AUGER OFF or AUGER REFILL ON Refill only ap plicable when installed See NOTE 3 lower right corner This is used to turn the ice control to OFF ICE or CHILL In ICE or CHILL mode Auger will turn ON 1 2 3 P3932 41047 031609 NOTE Refill system includes a Maximum Fill Time in the software If the time to fill the hopper exceeds this limit the hopper lights will flash and a Refill Fault will be dis...

Страница 5: ...d to turn the left side auger motor to AUGER ON AUGER OFF or AUGER REFILL ON Refill only ap plicable when installed See NOTE 3 bottom left corner This is used to turn the left side ice control to OFF ICE or CHILL In ICE or CHILL mode Auger will turn ON 4 bottom right corner This is used to turn the right side auger motor AUGER ON AUGER OFF or AUGER REFILL ON Refill only ap plicable when installed ...

Страница 6: ... screens hidden programming switches are used There are three of these switches that will be used for the setup of the dispenser 1 I O switch upper left corner of the control pad This switch is the ON OFF toggle switch which powers up the dispenser and the LCD display This switch is also used as back up switch in menu mode 2 ULTRA left under display When prompted by a selection from the menu to an...

Страница 7: ...RIAL NUMBER and ASSET NUMBER which toggle back and forth continuously I O MENU FUNCTION INDEX Press and hold for five seconds the GOURMET hidden switch to enter into the Menu Function Index The screens on the following page are in order that they appear from the menu display Pressing NO ULTRA or NEXT GOURMET will advance to the next function Press ON OFF I O will back up to the previous screen A o...

Страница 8: ...ET PASS WR 0 NEXT SERVICE TOOLS NO YES SET THICKNESS NO YES PASSWORD 0 NEXT DEFROST MINUTES OFF DAY TO CLEAN OFF NEXT DELAYED REFILL OFF 250 L REFILL 155 THRESHOLD AD MESSAGE DISABLED RESTORE DEFAULT NO YES TEST AUGERS NO YES SET LANGUAGE NO YES PM COMPLETE NO YES YES THICK ADJUST NEXT 250 R REFILL 155 THRESHOLD ENTER ASSET AN000000 MENU FUNCTION INDEX Continued These screens apply to Liquid Autof...

Страница 9: ...n hoppers are drained the augers will turn OFF Three messages will display after advancing past the last cleaning instruc tion FINISH NEXT PLEASE WAIT ULTRA VERSION __ __ CLEANING GUIDE NO Y E S DRAIN HOPPERS NEXT REMOVE HOPPERS AUGERS SEALS WASH SANITIZE ALL PARTS WASH FREEZING BARRELS WASH DRIP TRAY RE INSTALL HOPPER SEALS RE INSTALL AUGERS RE INSTALL HOPPERS LIDS REFILL WITH PRODUCT FINISH NEXT...

Страница 10: ...torque of each auger when answered YES ICE Two screens will appear for left and right The operator can scroll through a range of a minimum of 1 ULTRA to a maximum of 16 ICE Factory default is 10 SET THICKNESS NO YES LEFT 9 RIGHT 5 NOTE ULTRA 1 models will only have one adjustment screen 41047 041318 ...

Страница 11: ... A one minute time out will return to the Home Screen Set Time and Date Selecting YES allows the operator to set the DATE YY MM DD and TIME HR MIN SEC for display on the Home Screen SET DATE TIME NO YES YEAR 2005 NEXT TEST AUGERS NO YES LEFT AUGER TEST NEXT FORWARD Select NEXT to repeat process for Right Auger Test LEFT AUGER TEST NEXT OFF LEFT AUGER TEST NEXT REVERSE MONTH 1 NEXT MONTH DAY 25 NEX...

Страница 12: ... with the factory default being 0 Set Language Late Model Dispensers The setting of the Set Language mode allows the operator to scroll thru a list of languages stored in the software and select one for the display messages PASSWORD 0 NEXT SET LANGUAGE NO YES ENGLISH SELECT ESPANOL SELECCIONE CHANGE LANGUAGE ARE YOU SURE CHANGE LANGUAGE NO YES 41047 041318 ...

Страница 13: ... hours after waking up from the night time mode FREEZE MINUTES 60 DEFROST MINUTES OFF Set Night Time Set Day Time The setting of the Day Night mode allows the dispenser to power down during off hours The bottom corners displaying ICE will change to CHILL during the night mode During the night mode the product will be kept chilled to below 35 F ICE reading will return after night mode elapses With ...

Страница 14: ...tenance Due every six months The machine will not shut down if service is not performed When the service is performed and the message is answered YES ICE the time and date is recorded for another six months to elapse This feature can be DISABLED by pressing switch PM COMPLETE NO YES 6 MONTH PM ON 41047 041318 ...

Страница 15: ...nctions must be performed Either power off the dispenser using the I O ON OFF switch and allow the barrels or cooling drums to warm over 50 F or scroll to the Cleaning Guide and perform the cleaning service The barrels will warm to over 50 F when cleaned with warm water and the message will disappear NOTE The CLEAN DUE TODAY and CLEAN DUE NOW messages may be customized on late model ma chines All ...

Страница 16: ... This function allows the operator to lockout the touch pad Selecting ON provides no time delay on switches except for the center GOURMET hidden switch Selecting LOCKOUT provides a five second hold to wake up the touch pad and a two minute time frame from last button pressed to make adjustments before returning to sleep mode five second hold SWITCHES ON SWITCHES LOCKOUT 41047 041318 ...

Страница 17: ...ing between doses This can help the already frozen product from becoming deluted and not ready to serve These delay and fill times are to be determined and set based on each application as desired by the end user Default is set to OFF Pressing or sets to ON I O I O DELAYED REFILL OFF DELAYED REFILL ON I O FILL TIME SECONDS 10 I O DELAY TIME MINUTES 5 41047 041318 ...

Страница 18: ...st the Refill Threshold depending on the type of product being dis pensed 250 L REFILL 155 THRESHOLD 250 R REFILL 155 THRESHOLD TEST REFILL NO YES ACTIVATE VALVE LEFT DONE RIGHT I O ENABLE REFILL OFF ULTRA 1 Models only This function will activate the Liquid Autofill function only in machines equipped with this option 41047 041318 ...

Страница 19: ...THRU ALPHA NEXT NEXT LETTER AD MESSAGE SETUP COMPLETE MESSAGE SCROL DONE NEXT AD MESSAGE DISABLED AD MESSAGE ENABLED Ad Messages Enabled Late Model Dispensers This function allows the operator to create an AD Message that will toggle with the Home Screen mes sages 41047 041318 ...

Страница 20: ...reference Default is set to DISABLE Pressing or sets to ENABLE I O I O SERVICE PHONE DISABLE SERVICE PHONE ENABLE Back To Menu Scrolls Thru Numbers Goes To Next Digit I O I O I O I O SAVE NO EDIT YES MODIFY SERVICE NO YES SCROL THRU ALPHA NEXT NEXT LETTER 217 529 6601 SCROL DONE NEXT 41047 041318 ...

Страница 21: ...y access the first four functions Cleaning Guide Set Consistency Test Augers and Set Date Time SET PASS WR 0 NEXT SET PASS WR 9999 NEXT Enter Asset Number This is the function to set the asset number using a range of 0 to 999999 the factory default is 0 It is used to track the usage or service of an individual machine within a group ENTER ASSET AN000000 41047 041318 ...

Страница 22: ... Same As Page 11 NOTE Functioning switch will display it s respective name on the screen when depressed Press power I O switch to exit I O I O I O I O I O TEST OUTPUTS NO YES TEST AUGERS NO YES TEST SWITCHES NO YES TO EXIT DEPRESS POWER I O SWITCH NO SWITCHES ARE DEPRESSED SERVICE TOOLS NO YES 41047 041318 ...

Страница 23: ...efill Threshold 155 11 Cleaning Message RESET 12 AD Message RESET I O I O I O I O I O I O Install Date The following three screens will scroll after advancing past the function Restore Defaults The Install Date and Time is recorded when the dispenser is powered on for the first 100 hours The Install Date and Time cannot be reset and is stored in permanent memory RESTORE DEFAULT NO YES ARE YOU SURE...

Страница 24: ...splayed continuously Press and release the ULTRA and ICE hidden switches to return to HOME SCREEN The TEMP TORQUE mode is typically used for service NOTE ULTRA 1 models will display Barrel Temperature and Torque readings on the left side of the display 41047 041318 I O 0 FAN CMP 0 67 67 h fan Fan is OFF FAN Fan is ON cmp Compressor is OFF CMP Compressor is ON On right or left indicates respective ...

Отзывы: