Bunn 10010.0000 Скачать руководство пользователя страница 3

3

CONTENTS

46819 043012

INTRODUCTION

This equipment heats and dispenses water on demand for beverages and cooking purposes.  It has a panel 

above the faucet that indicates the status of the dispenser.  This equipment is for indoor use, either wall-mounted 

(H5E/X/PC) or on a sturdy counter or shelf.

WARRANTY ........................................................................................................... 2

INTRODUCTION ..................................................................................................... 3

USER NOTICES ...................................................................................................... 4

ELECTRICAL REQUIREMENTS ............................................................................... 5

PLUMBING REQUIREMENTS ................................................................................. 6

INITIAL SET-UP (H5E, H5X, H5-PC, H5 ELEMENT, H10X) ..................................... 6

INITIAL SET-UP H5M, HW2, OHW ......................................................................... 7

OPERATING CONTROLS (H5-PC ONLY) ................................................................. 8

ADJUST DISPENSE VOLUME (H5-PC ONLY) ......................................................... 8

PROGRAMMING (H5E, H5X, H5-PC, H10X) .......................................................... 9

PROGRAMMING (H5 ELEMENT) ......................................................................... 11

DRAINING THE DISPENSER ................................................................................ 14

CLEANING ............................................................................................................ 14

-1000

213.8

101.0

200

93.3

-500

212.9

100.5

200

93.3

0

212.0

100.0

200

93.3

500

211.1

99.5

200

93.3

1000

210.2

99.0

200

93.3

1500

209.3

98.5

200

93.3

2000

208.4

98.0

200

93.3

2500

207.4

97.4

200

93.3

3000

206.5

96.9

199

92.8

3500

205.6

96.4

198

92.2

4000

204.7

95.9

197

91.7

4500

203.8

95.4

196

91.1

5000

202.9

94.9

195

90.6

5500

201.9

94.4

195

90.6

6000

201.0

93.9

194

90.0

6500

200.1

93.4

193

89.4

7000

199.2

92.9

192

88.9

7500

198.3

92.4

191

88.3

8000

197.4

91.9

190

87.8

8500

196.5

91.4

189

87.2

9000

195.5

90.8

188

86.7

9500

194.6

90.3

187

86.1

10000

193.7

89.8

186

85.6

Brew water temperature is factory set at 200

°

 F (93.3

°

 C)

Areas of high altitude will require lowering this tempera-

ture to prevent boiling.  This chart should be used as a

guide when readjusting the brew water temperature.

Altitude

(Feet)

Boiling point

of water

°

 F          

°

 C

Recommended

water temperature

°

 F          

°

 C

Содержание 10010.0000

Страница 1: ...it the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way to obtain the latest catalog and manual updates Contact Bunn O Matic Corporation at 1 800 286 6070 to obtain a paper copy of the required Illustrated Parts Catalog mailed via U S Postal Service 46819 0000A 06 12 2012 BUNN O MATIC CORPORATION Hot Water Dispensers Supercedes 10052 0000 10010 0000 10267 0000 1042...

Страница 2: ...s to this warranty or to make additional warranties that are binding on BUNN Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive op tion while the equipment is under warranty shall either 1 provide at no charge...

Страница 3: ... 93 3 500 212 9 100 5 200 93 3 0 212 0 100 0 200 93 3 500 211 1 99 5 200 93 3 1000 210 2 99 0 200 93 3 1500 209 3 98 5 200 93 3 2000 208 4 98 0 200 93 3 2500 207 4 97 4 200 93 3 3000 206 5 96 9 199 92 8 3500 205 6 96 4 198 92 2 4000 204 7 95 9 197 91 7 4500 203 8 95 4 196 91 1 5000 202 9 94 9 195 90 6 5500 201 9 94 4 195 90 6 6000 201 0 93 9 194 90 0 6500 200 1 93 4 193 89 4 7000 199 2 92 9 192 88...

Страница 4: ...Fill water tank before turning on thermostat or connecting appliance to power source Use only on a properly protected circuit capable of the rated load Electrically ground the chassis Follow national local electrical codes Do not use near combustibles FAILURE TO COMPLY RISKS EQUIPMENT DAMAGE FIRE OR SHOCK HAZARD READ THE ENTIRE OPERATING MANUAL BEFORE BUYING OR USING THIS PRODUCT THIS APPLIANCE IS...

Страница 5: ...for Initial Set Up CE REQUIREMENTS This appliance must be installed in locations where it can be overseen by trained personnel For proper operation this appliance must be installed where the tem perature is between 5 C to 35 C Appliance shall not be tilted more than 10 for safe operation An electrician must provide electrical service as specified in conformance with all local and national codes Th...

Страница 6: ...ected to a COLD WATER system with operating pressure between 20 and 90 psi 138 and 620 kPa from a or larger supply line A shut off valve should be installed in the line before the dis penser Install a regulator in the line when pressure is greater than 90 psi 620 kPa to reduce it to 50 psi 345 kPa The water inlet fitting is flare NOTE Bunn O Matic recommends tubing for installations of less than 2...

Страница 7: ...ve the center rear panel and rotate the control ther mostat knob fully clockwise to the ON position and replace the panel 5 Plug in the dispenser and wait approximately twenty minutes for the water in the tank to heat The dispenser is ready for use INITIAL SET UP OHW CAUTION The dispenser must be unplugged throughout the initial set up except when specified in the instructions 1 Place an empty ves...

Страница 8: ...d the hidden programming button c located under the next to the BUNN logo on the front of the dispenser until the 3 LED s begin flashing from the left to the right Release the button 2 Place an empty graduated container under the dispense nozzle e 3 Press and release the batch size to be set a The LED s will stop flashing and the LED over the button just pressed will come on steady Water will begi...

Страница 9: ...e center button The display will now show the model number ex H5H Now scroll with the buttons through the models listed above until the display matches the model you are working with 3 Press and release the center button once more The display will show P2 Display will now show the tank temperature ex 200 Press the button to increase the temperature set point or the button to decrease the set point...

Страница 10: ... Degrees in Centigrade 2 Press and release the or buttons to alternate between FAH and CEn 3 AftersettingFAHorCEn toexitLevel2Programming pressandreleasethecenter button twice Display will show software version then model number then H3 RESTORING FACTORY DEFAULTS 1 To restore Factory Defaults This clears all settings that were previously entered press and release the center button untilH2 appears ...

Страница 11: ... indicate it is in the energy save mode 3 Repeat procedure to exit energy save mode Programming the dispenser 1 Press and hold upper hidden button bottom center of BUNN logo until P1 is displayed Adjusting temperature The switch must be in the SET position in order to access the program modes 1 Press and hold TEMP button until display flashes 2 While display is flashing press and release the to in...

Страница 12: ...pper hidden button once more The display will read P3 then show the ready temperature set point Range 2 to 20 below the SET temperature 5 Press the button to increase or the button to decrease the set point 6 Press and release the upper hidden button once more The display will read P4 This screen will allow you to turn the Auto energy save mode ON OFF NOTE Turning off this function will disable P5...

Страница 13: ... all settings that were previously entered press and release the upper hidden button until H2 appears on the display ap proximately 6 seconds Release the upper hidden Button then press and release the upper hidden Button once more The display will read H3 then show 2 Press and hold both and buttons to initiate the resetting of the factory default settings The display will flash on and off during t...

Страница 14: ...ws and the top cover 4 Gently remove one of the grommets from the tank lid 5 Insert a tube to the bottom of the tank and syphon ALL of the water out CLEANING The use of a damp cloth rinsed in any mild non abrasive liquid detergent is recommended for cleaning all surfaces on Bunn O Matic equipment WALL MOUNTED INSTALLATION 5 GALLON MODELS ONLY If the dispenser is wall mounted the bottom of the disp...