background image

hellas-manual-en

Page 4 / 9 

Intended Use

Exposure of positive or negative developing photoresist, solder mask and Alucorex.
All other application need our written consent or happen on risk of the operator.

The Bungard  GmbH  & Co. KG accepts no liability for damages incurred in non-authorised use or
application of the machine. 

Safety instructions

Generally
Please   read   the   following   text   carefully   and   pay   particular   attention   to   the   information   on
occupational safety and commissioning. 
Please   keep   this   folder   carefully.   It   contains   information   that   is   also   important   for   later
maintenance or cleaning work.
The   machines   are   not   intended   for   integration   or   interconnection   with   other   machines   or
systems.  They may only be operated in rooms equipped for this purpose and may only be
operated by qualified specialist personnel. Keep children and pets away!
The Hellas is designed for use in the laboratory. The device may only be serviced by a qualified
specialist.  The user should never try to do more for the maintenance of  his device than is
allowed to do according to the operating instructions. He should always consult a specialist for
maintenance work that is beyond his authority.
transport
Use only suitable lifting and transport equipment such as forklifts or pallet trucks. Secure the
machine against slipping / tipping. Risk of damage!
site
The  machine   needs   a  flat   table   of   approx.   700  x  800mm.   There  must   be  sufficient   space
around the machine for operation and maintenance.
Do not place the device near heat sources such as radiators, warm air ducts, ovens and the
like.
The installation environment is crucial for problem-free work with the Hellas. You must therefore
place  particular   emphasis   on a  room  that   is as  dust-free  as  possible  and  room  air  free   of
corrosive vapors in order to ensure that it functions properly.
Electrical
The machine is manufactured using tested parts according to the usual guidelines for electrical
safety. However, this does not release the user from his duty of care when handling electrically
operated devices.
Only connect the device to the power source marked in the operating instructions or on the
device. We  assume that  the power source will be protected  on-site.  The connection to the
power supply may only be carried out by a specialist.
The circuit and the fault circuit must be protected by the customer.
Before starting any work on the machine (cleaning, etc.) and when not in use for a long time,
switch off the machine and pull out the mains plug.

fluorescent tubes
Due to the high intensity of the emitted light, it is u. It may be uncomfortable to look into the
fluorescent tubes that are switched on. However, the danger of the emitted UV light is just as
low as that of tube-equipped tanning devices. Intended use is in the closed state to avoid eye
injuries
Avoid contamination with iron chloride. Because of its reddish-brown color, they lead to a partial
absorption of UV light.

Bungard Elektronik GmbH & Co. KG, Rilkestraße 1, 51570 Windeck – Germany

Tel.: +49 (0) 2292/9 28 28 - 0, Fax: +49 (0) 2292/9 28 28 - 29, E-mail: [email protected]

Содержание Hellas E

Страница 1: ... Technical Data 2 EG Declaration of Conformity 3 Intended Use 4 Safety instructions 4 Set Up 5 Operating 5 Spare Part List 7 Guarantee 8 Disclaimer of Warranty 8 Copyright 9 Bungard Elektronik GmbH Co KG Rilkestraße 1 51570 Windeck Germany Tel 49 0 2292 9 28 28 0 Fax 49 0 2292 9 28 28 29 E mail support bungard de ...

Страница 2: ...nted illuminated switches Maintenance free all steel construction cover safety switch optional Applications With the vacuum Hellas unit you can process all photosensitive products with spectral sensitivity in the near UV range 360 400nm These are especially positive or negative photo coated pcbs printing plates made of nylon aluminum steel and diazo and transfer films Options Quick release button ...

Страница 3: ...schinen Teil 1 Allgemeine Anforderungen Safety of machinery Electrical equipment of machines Part 1 General requirements DIN EN ISO 14121 1 Sicherheit von Maschinen Risikobeurteilung Teil 1 Leitsätze Safety of machinery Risk assessment Part 1 Principles DIN EN ISO 12100 1 Sicherheit von Maschinen Allgemeine Gestaltungsleitsätze Risikobeurteilung und Risikominderung Safety of machinery Basic concep...

Страница 4: ...und the machine for operation and maintenance Do not place the device near heat sources such as radiators warm air ducts ovens and the like The installation environment is crucial for problem free work with the Hellas You must therefore place particular emphasis on a room that is as dust free as possible and room air free of corrosive vapors in order to ensure that it functions properly Electrical...

Страница 5: ...form us and the carrier Remove the tape locking the cover and verify that the fluorescent tubes have not been damaged during transport To do so take the cover s handle and lift it so that the cover stands vertically on the rear mounted rubber pads Looking onto the lower part of the set you can see the vacuum frame with its polyester foil spanning over a crystal glass plate Please check the foil th...

Страница 6: ... that there is a built in fan always running together with the lower tube set Hellas E there is no switch for continuous exposure Timer The exposure time is controlled by a digital read out and digital adjustable timer The range of time is from 1 second to 9 minutes 59 seconds The device supports easy time pre selection and recall by one hand operation and can be run in stop and go turns On the ti...

Страница 7: ...their axis until they snap off from the fittings Replace them only with tubes of the same type and strength Check that the new tubes are well locked It is recommended also to replace the starters We want to tear your special attention to a careful maintenance of the vacuum foil It should be cleaned regularly using water and a soft detergent Do not use solvents Be extremely careful not to contamina...

Страница 8: ...arent plastic sheet Guarantee All machines are submitted before distribution to examination on function and continuous operation firmness On the machine we grant a work warranty of 12 months to our customers starting from purchase date on accuracy in material and processing We warrant at our choice by exchange of incorrect parts or by repair of the machine in our house Old parts change into our po...

Страница 9: ...mage or destruction of work pieces worked on in the machine because we have no knowledge or control over the operating conditions at your site This is valid in a general manner also for requirements from damage to articles buildings and persons as well as the environment We do not warrant that the function of the machine will meet the customer s requirements or that the operation of the machine wi...

Отзывы: