background image

Installing the Equipment, cont.

Dress input wires

1

 

Connect input wires from 

RM4014 

to output terminals of your device.

2

 

Dress input wires inside enclosure, making sure wires do not slip through opening of faceplate.

3

 

Tighten fitting on bottom of enclosure.

4

 

Turn 

ON 

your device. Wait at least 2 minutes.

4

The following procedure provides general steps for configuring the 

RM4014

 for service using Bullhorn Tools. Before 

beginning the configuration steps, ensure that

 Bullhorn Tools is installed on your laptop. The software can 

be downloaded 

from the 

Downloads 

page on the Bullhorn RMU Support site (

www.support.aiworldwide.com/products/bh2

). 

 

 

Configuring the RM4014 for Service

For additional information or questions, please contact Technical Support at 1-800-229-3404 or [email protected]

Bullhorn RM4014 Installation & Configuration Quick Reference Guide

© 

2016-2020 American Innovations, Ltd. 

Part No. 122215-000 Rev. 3

1

  Ensure that the configuration cable is connected to the 

RM4014

 and your laptop and the unit is powered on. 

2

  Open Bullhorn Tools. After the scan has completed, click        

Connect 

to open the 

Unit Overview 

window.

2 of 2

3

  Click      

Refresh 

to update unit settings.

4

  Click      

Send Test Message

 to verify communications.

5

  Load or import a saved template, if available (

File > Load Template

).

6

 

Click       

Reporting & Power 

to adjust unit clock, create a transmission schedule, check battery information, 

and set AC outage delay alarm times.

7

 

For interruption only

 - click      

Interruption 

and configure interruption and (optional) interference settings. 

Click      

Verify Interruption

 button (on 

Unit Overview

 window) to verify process is working correctly

.

8

 Configure 

Readings

, including Analog and Digital. 

Digital 5

 can be configured as an accumulator.

 

9

 

Exit Bullhorn Tools and disconnect configuration cable.

10

  Close and secure enclosure door

.