background image

©2020 Bullard. All rights reserved. 

6081509758I (0420)

ISO 9001 

certified

www.bullard.com

Bullard Center

2421 Fortune Drive
Lexington, KY 40509 • USA
877-BULLARD (285-5273)
Tel: +1-859-234-6616
Fax: +1-859-246-0243

Americas Operations

1898 Safety Way
Cynthiana, KY 41031 • USA
877-BULLARD (285-5273)
Tel: +1-859-234-6616
Fax: +1-859-234-8987

Bullard GmbH

Dieselstrasse 8a
53424 Remagen • Germany
Tel: +49-2642 999980
Fax: +49-2642 9999829

Bullard Asia Pacific Pte. Ltd.

51 Changi Business Park Central 2
#03-04 The Signature
Singapore 486066
Tel: +65 6745 0556
Fax: +65 6797 0299

Содержание EVAHL Series

Страница 1: ...t use these respirators for respiratory protection during abrasive blasting or clean up 4 Do not use in circumstances where the airborne concentration level of contaminant exceeds maximum use concentration for this type of respirator as established by regulatory standards 5 Leave area immediately if Breathing becomes difficult Dizziness or other distress occurs You taste or smell the contaminant U...

Страница 2: ...edium size 20LF2L Loose fitting facepiece narrow profile large size 6 The Battery Charger EVAHLSMC Quick charger single port EVAHLGC Gang charger six port The blower unit draws in ambient air through the cartridges The purified air is blown into the wearer s hood through the breathing tube A flow indicator is provided to check that there is an adequate volume of air available to the wearer prior t...

Страница 3: ...terioration physical damage and improper assembly 2 Filter Cartridges Inspect the filter cartridge for any physical damage Check the label to ensure the filter cartridge has not exceeded its use by date Inspect the gasket on the filter for any phsyical damage NOTE Each filter comes with a permanent gasket Ensure that the correct filter cartridge is appropriate for the contaminant Consult the NIOSH...

Страница 4: ...particulate filters are 99 97 effective against all particulate aerosols The following abbreviations are approved by NIOSH to indicate the particulates gases or vapors which are removed by the gas vapor cartridges HE High Efficiency Particulate OV Organic Vapor AM Ammonia CD Chlorine Dioxide CL Chlorine FM Formaldehyde HC Hydrogen Chloride HF Hydrogen fluoride MA Methylamine SD Sulfur Dioxide Moun...

Страница 5: ...ead during use first verify proper air pressure then select a different hood for your application or use the optional chin strap Adjusting and Installing Hard Hat in Respirator Hood 20SICH 20TICH 1 Assemble and adjust the standard Bullard hard hat suspensions RS4PC or RS6PC or the optional ratchet suspensions RS4RC or RS6RC by following the directions on instruction sheet attached to headband on h...

Страница 6: ...hing 6 Ensure that the neck cuff is down below the chin and that the air outlets of the cuff see Figure 27 are not restricted If the neck cuff is not below the chin then pull down before continuing See Figure 27 RT Series Hood Use Installing Breathing Tube Assembly in RT Series Respirator Hoods For hoods without a threaded port at the rear Breathing Tubes PA1BT PA1BTXS and PA1BTXL will attach to t...

Страница 7: ...ttach the other end of breathing tube to blower unit if not already attached by screwing adapters together Remove any protective film covering the lens of the headpiece Put on the belt and blower assembly and make any final adjustments to the belt as necessary keeping the breathing tube and hood behind the head Turn the blower on by depressing and holding the on off switch Figure 33 for approximat...

Страница 8: ...will automatically cease operation Doffing the Respirator Prepare to doff the blower battery and hood in a safe hazard free area and do the following in conjunction with your employer s standard operating procedures Remove the hood Turn the blower off by holding down the ON OFF switch for 5 seconds This is confirmed by a long beep and a shut down of the motor Remove the waist belt Disconnect the h...

Страница 9: ...SSEMBLIES ALTERNATE SUSPENSION HARD HAT ASSEMBLIES ALTERNATE BREATHING TUBES ALTERNATE BLOWER UNIT ASSEMBLIES FILTER ASSEMBLY ALTERNATE CARTRIDGE ASSEMBLIES ALTERNATE BATTERY CONFIGURATIONS ALTERNATE BELT ASSEMBLIES ALTERNATE CHARGER ASSEMBLIES ACCESSORIES CAUTIONS AND LIMITATIONS2 20LFXL 20LFL 20LFM 20LFXLHE 20LFLHE 20LFMHE 20LF2L 20LF2M 20LF2S 20LF2LHE 20LF2MHE 20LF2SHE 20TJN 20TJNT 20TICN 20TIC...

Страница 10: ...ullard will accept any returned goods Please read carefully Follow the steps outlined below to return goods to Bullard for repair or replacement under warranty or for paid repairs 1 Contact Bullard Sales Support by telephone or in writing at Bullard 1898 Safety Way Cynthiana KY 41031 9303 Toll free 877 BULLARD 285 5273 Phone 859 234 6616 In your correspondence or conversation with Sales Support de...

Страница 11: ...cepieceTychem 2000Traditional Large HEPA 20LFMHE 20LF LF FacepieceTychem 2000Traditional Medium HEPA 20LFXLHE 20LF LF FacepieceTychem 2000Traditional XL HEPA Double bib hood for use without a headband suspension RT1 RT1T Tychem 2000 QC Inflatable neck collar RT2 RT2T Tychem 4000 SL Inflatable neck collar RT3 RT3T Tychem 2000 QC Sport neck collar RT4 RT4T Tychem 4000 SL Sport neck collar Accessory ...

Страница 12: ...59 234 6616 Fax 1 859 246 0243 Americas Operations 1898 Safety Way Cynthiana KY 41031 USA 877 BULLARD 285 5273 Tel 1 859 234 6616 Fax 1 859 234 8987 Bullard GmbH Dieselstrasse 8a 53424 Remagen Germany Tel 49 2642 999980 Fax 49 2642 9999829 Bullard Asia Pacific Pte Ltd 51 Changi Business Park Central 2 03 04The Signature Singapore 486066 Tel 65 6745 0556 Fax 65 6797 0299 ...

Отзывы: