DC50 Series Dual-Cool Climate Control 

Tube and DC70 Vest Instruction Sheet

Operating the Dual-Cool Tube

1.  To obtain cooler air, turn the air temperature control knobs counterclockwise 

(Figure 3)

. Maximum cooling is obtained when knobs are open completely 

and when there is maximum airflow out of the Dual-Cool tube’s exhaust ports. 
To obtain air that is closer to ambient temperature, turn air temperature 
control knobs clockwise. If knobs are closed completely, your respirator will 
receive air that is essentially at ambient temperature.

nOTe

There are separate controls to adjust the temperature of the air that 
is distributed to the vest and the breathing zone. The right-hand knob 
controls the air temperature to the respirator; the left-hand knob 
controls the air temperature to the cooling vest

 (Figure 3)

.

2.  When finished working, leave the work area wearing the respirator. With the 

air still flowing, remove the hood, and then disconnect the air supply hose 
using the quick-disconnect coupler attached to the Dual-Cool.

Cleaning

Machine wash the vest in warm water using a gentle cycle.  Use a mild laundry 
detergent.  Air-dry only.  After cleaning, carefully inspect the vest for any signs 
of damage.  If any damage is detected, remove the vest from service.

Содержание DC50 Series

Страница 1: ...ments for Grade D breathable air include Oxygen 19 5 23 5 Hydrocarbons in mg m3 of gas 5 mg m3 max Carbon monoxide 10 ppm max Carbon dioxide 1 000 ppm max Odor No pronounced odor No toxic contaminants at levels that make air unsafe to breathe Specific measurement of odor in gaseous air is impractical Air normally may have a slight odor The presence of a pronounced odor should render the air unsati...

Страница 2: ...r Bullard V5 Series hose in lengths of 25 to 50 feet Bullard V11 hose to hose adapters MUST be used to connect V10 hose lengths together Secure connection s until wrench tight and leak free Warning Warning The DC50 Dual Cool climate control system is not recommended for cooling the air supply when the air temperature is less than 70 F Because the DC50 Dual Cool may cool the incoming air by more th...

Страница 3: ...Cool assembly is on your right hand side 3 Don the vest Use the Velcro closure strips to adjust loosely for size NOTE The vest should mount over the belt with the Dual Cool unit positioned in the V of the vest found on the right hand side Figure 1 4 Snap the quick disconnect nipple found on the end of the cooling vest connector hose into the quick disconnect coupler on the Dual Cool Figure 3 5 Don...

Страница 4: ...s maximum airflow out of the Dual Cool tube s exhaust ports To obtain air that is closer to ambient temperature turn air temperature control knobs clockwise If knobs are closed completely your respirator will receive air that is essentially at ambient temperature NOTE There are separate controls to adjust the temperature of the air that is distributed to the vest and the breathing zone The right h...

Отзывы: