![Bull Escala Power7 Series Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/bull/escala-power7-series/escala-power7-series_manual_2828769036.webp)
v
If there are no problems with 10009
xxx
reference codes, press Enter to return to the command
line.
v
If there are problems with 10009
xxx
reference codes, there might be problems with the SPCN
loop. Perform problem analysis on the problems to correct them before continuing. If you need
assistance, contact your service provider.
f.
Go to step 8.
6.
Use the AIX error log to verify that there are no 10009
xxx
errors (where
x
is any character 0 - 9 or A
- F) by completing the following steps.
a.
Log in as the root user, or use the CE login. If you need assistance, contact the system
administrator.
b.
Type
diag -d sysplanar0 -E xx
and press Enter, where xx is any number 1 - 60 that specifies a
number of days. This command returns all 10009
xxx
error log entries for the most recent number
of days specified. The suggested range is 30 days.
c.
Highlight the
Problem Determination
option in the DIAGNOSTIC MODE SELECTION display.
Press Enter.
d.
Search the results that are displayed to identify problems with 10009
xxx
reference codes. You
might need to scroll down in the display to see all of the results.
Note:
If the Problem Determination results contain serviceable events that have already been
reported, the PREVIOUS DIAGNOSTICS RESULTS display is shown. Respond to the
Do you
want to review these previously reported errors?
prompt by highlighting the YES response, and
then press Enter.
e.
Based on the results of your search, perform one of the following options:
v
If there are no problems with 10009
xxx
reference codes, press Enter to return to the command
line.
v
If there are problems with 10009
xxx
reference codes, there might be problems with the SPCN
loop. Perform problem analysis on the problems to correct them before continuing. If you need
assistance, contact your service provider.
f.
Go to step 8.
7.
Use the Linux error log to verify that there are no 10009
xxx
errors (where
x
is any character 0 - 9 or
A - F) by completing the following steps.
a.
Log in as the root user. If you need assistance, contact the system administrator.
b.
Type
servicelog --query='refcode like "10009%" AND serviceable=1 AND closed=0'
and press
Enter
c.
Search the results that are displayed for problems with 10009
xxx
reference codes and statuses that
are open. If there are problems with 10009
xxx
reference codes, there might be problems with the
SPCN loop. Perform problem analysis on the problems to correct them before continuing. If you
need assistance, contact your service provider.
Note:
You might need to scroll down in the display to see all of the results.
d.
Go to step 8.
8.
Verify that no inactive expansion units are in the SPCN by performing the following steps:
a.
Access the ASMI by using an authority level of administrator or authorized service provider. For
details about using the ASMI, see Managing the Advanced System Management Interface
(http://publib.boulder.ibm.com/infocenter/systems/scope/hw/topic/p7hby/asmi.htm).
b.
In the ASMI navigation area, expand
System Configuration
and click
Configure I/O Enclosures
.
c.
Scan for inactive expansion units by looking for rows that show
Inactive
in the Status column. If
inactive expansion units exist, perform the following steps:
24
Enclosures and expansion units
Содержание Escala Power7 Series
Страница 1: ...Enclosures and expansion units ESCALA Power7 REFERENCE 86 A1 23FF 07 ...
Страница 2: ......
Страница 88: ...76 Enclosures and expansion units ...
Страница 146: ...134 Enclosures and expansion units ...
Страница 147: ......
Страница 148: ...Printed in USA ...