TS1
Temperature
Set Value 1
Heating
Differential
Temperature
Calibration
Temperature
Unit
25°C / 77°F
DS1
.5°C / .5°F
SET
SET
SET
SET
HOLD
SET
FOR
3 SECONDS FOR
SET-UP MODE
CA
0°C / 0°F
CF
F
OVERVIEW
The Bulk Reef Supply Heater controller is a pre-wired
heating output temperature controller for use with
a separate heating element. This heater controller
offers some key advantages that ensure long-term
accuracy and reliability.
MAIN FEATURES
• Dual display window; displays measured
temperature (
PV
)
and set temperature (
SV
)
at the same time
• Fast and easy programming
• Temperature calibration
• Adjustable control precision; down
to 0.3°F heating differential value
• Replaceable probe
• Large power output (Max load: 1,200W (110v))
• Sensor fault alarm
• Supports readings in Fahrenheit or Celsius
• Over-temperature alarm
OPERATING KEYS
PV: Process Value
Displays current temperature
In setting mode: displays menu code
SV: Setting Value
Displays set temperature
In setting mode: displays setting value
Heater Indicator Lamp
When lit, indicates outlets are on
SET
Press
SET
for 3 seconds to enter menu for
parameter setting. When done, press
SET
for
3 seconds to quit and save setting changes
Increase
In setting mode: press
p
to increase or
change setting value
Decrease
In setting mode: press
q
to decrease or
change setting value
Socket
Both sockets are for heating output and are
synchronized
SPECIFICATIONS
Control Range
-50°
to
37.7°C / -58°
to
99.9°F
Control Precision
0.3° to 15°C / 0.3° to 15°F
Display Resolution
0.1°C / 0.1°F
Accuracy
±1°C / ±1°F
Control Mode
On/Off Control, Heating
Input Power
100 to 265VAC, 50Hz/60Hz
Output
Max. 10A, 100V to 265VAC
Sensor Type
NTC sensor
Sensor Length
6.5’
Relay Contact
Capacity
Heating (10A, 100 to 240VAC)
Cable Length
Input: 5’ / Output:1’
Body Dimension
5.5x2.7x1.3”
Socket Dimension
3.3x1.7x1”
Ambient
Temperature
-30° to 75°C / -22° to 167°F
Storage
-20° to 60°C / -4° to 140°F
Humidity 20 to 85%
(No Condensate )
Warranty
1 Year
1
2
3
4
5
6
7
PROGRAMMING
When the controller is working normally, press
SET
for 3 seconds to enter parameter setting mode.
PV
window displays the temperature setting code
TS1
,
while
SV
window displays according setting value.
Press
SET
to go to the next menu; press
p
or
q
key to set desired parameter value.
When finished, press
SET
for 3 seconds to save the
settings and return to normal temperature display
mode. While in setting mode, if there is no operation
for 10 seconds, the system will automatically quit
setting mode and return to normal temperature
display mode without saving changes.