Master/Slave Fixture Linking
1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin
connector of the first fixture.
2. Connect the end of the cable coming from the first fixture which will have a (female) 3
pin connector to the input connector of the next fixture consisting of a (male) 3 pin
connector. Then,proceed to connect from the output as stated above to the input of the
following fixture and so on.
9
O
ften, the setup for Master-Slave and Standalone operation
requires that the first fixture in the chain be initialized for this
purpose via either settings in the control panel or DIPswitches.
Secondarily, the fixtures that follow may also require a
slave
setting. Please consult the “Operating Instructions” section in
this manual for complete instructions for this type of setup and
configuration.
TO DMX
CONTROLLER
1---GND
2---DATA-
3---DATA+
TO AC POWER SUPPLY
GND---(GREEN / YELLOW CABLE)
NEUTRAL---(WHTE / BLUE CABLE)
LIVE---(BLACK / BROWN CABLE)
TO THE NEXT
UNIT