MAX
MIN
- 90 -
en
Adjusting the heat
Adjustment of temperature can be done by using thermostat (recommended use)
or manually.
The desired mode is choosen by turning the regulation knob (2) min - max - min –
max, by doing this the unit is switched to either to thermostat- or to manual mode.
When thermostat mode is chosen the thermostat light (5) is on. In manual mode
the thermostat light (5) is off. Note ! the heater will remember it’s last mode ie. if it
is shut down in thermostat mode next time when ignited it it will start in the same
mode ie. thermostat mode.
Thermostat mode
Temperature is controlled by the thermostat (recommended use)
The device starts when the heating switch (3) is pressed in continuously for at least
2 seconds, after which the yellow power indicator light (9) lights to indicate that the
power is on.
The red combustion indicator light (1) will be lit, when the burner flame has been
ignited and combustion has stabilised after ca. 2.5 - 4 min from when the heating
was turned on.
The starting phase will take about 11 minutes. After this phase the heater will run
according to set power or can be adjusted by turning the knob.
After the heater has passed the ignition phase, you can adjust the thermostat set-
ting using the temperature control knob (2). Turn the knob to set the temperature to
your desired setting.
The sun-switch shuts down the device automatically, if the temperature rises above
the requested temperature, for example, due to sunlight. The temperature must
rise by +3 °C above the set value for a half an hour. If the device has been shut
down by the sun-switch, an indicator light (5) blinks on the thermostat. The sun-
switch can be turned off temporarily, by turning the temperature control (2).
A heater that has been shut down can be restarted manually, if necessary.
Conservation temperature: the temperature control (2) is set to minimum , and
the cabin is maintained at a temperature of +2 – +8 °C. The sun-switch is not ena-
bled in this mode.
Temperature of cabin can be found out by turning the knob (2) until the brightness
of the thermostat light (5) will change. The position of knob (2) inform about the
cabin temperature.
Manual use
The power is adjusted manually.
To enable this function, turn the power adjuster (2) to positions min - max - min –
max.
The device signals that the function has been activated when the theromstat light
(5) shuts down.
After the heater has been started up, the power can be adjusted step-less with
the power adjustment knob (2). Avoid turning the adjustment knob back and forth
rapidly, as this can cause the burner to become sooty.
when power control knob (2) is turned to position 1 or 2 , unit is running on mini-
mum effect.
when power control knob (2) is turned to position 2 or 6 , unit is running on maxi-
mum effect.
From manual mode to thermostat mode you can go by turning the knob (2) min -
max - min – max. As a confirmation of mode change the thermostat light (5) will go
on.
1
2
0
00t
Operation
D10431
490603
Содержание 2000t
Страница 15: ... 15 fi 2000t Asennus D10430 490603 ...
Страница 44: ... 44 sv 2000t Installering D10432 490603 ...
Страница 73: ... 73 en 2000t Installation D10431 490603 ...
Страница 102: ... 102 de 2000t Einbau D10433 490603 ...
Страница 126: ...en D50311 126 490603 ...
Страница 127: ...D900192 127 490603 ...
Страница 128: ...D900192 128 490603 ...