S3-915M
User manual
24
Y2 is NbGateways
Y3 is the downstream RSSI
Y4 is the downstream SNR
Example
AT+CLINKCHECK=1
OK
+
CLINKCHECK: 0
,
0
,
1
,
-68
,
8
Precautions
Need to set before sending data
Command
character
Command
Type
Command Format
response
CRXP
(
Set the receive
window
parameters
)
Test
command
AT+CRXP=?
+CRXP:
“
RX1DRoffest
”
,
”
RX2DataRate
”
,
”
RX2Frequency
”
OK
Setting
command
AT+CRXP?
+CRXP:<RX1DRoffest>,<RX2DataRate
>,<RX2Frequency>
OK
Parameter
Description
AT+CRXP=<RX1DRoffest>,<
RX2DataRate>,<RX2Frequen
cy>
OK
Return value
description
<RX1DRoffest>,<RX2DataRate>,<RX2Frequency>
详见
LoRaWAN
协
议。
Example
Precautions
AT+CRXP=1,1,471000000
OK
Test
command
Need to be set before sending data. Use the default value when not setting.
Command
character
Command
Type
Command Format
response
CRX1DELAY
(
Set the number
of times sent
)
Test
command
AT+CRX1DELAY=?
+CRX1DELAY:
“
Delay
”
OK
Query
command
AT+CRX1DELAY?
+CRX1DELAY:<Delay>
OK
Setting
command
AT+CRX1DELAY=<Delay>
OK
Parameter
Description
Delay: how long to open rx1 window after sending, unit: s;
Return value
description
Example
AT+CRX1DELAY=2