Ensure  that  the  equipment  is  depressurised  and  electrically  isolated  prior  to  carrying  out  any  of  the 
scheduled maintenance instructions specified within this user guide. 

3.3

 

External Power Supply – 230v and 110v operation 

In the event of a hazard or malfunction, the power should be switched off at the socket before being unplugged 
from the mains. 

The power lead should only be plugged into the air receiver power input socket. Check to ensure your electricity 
supply matches that shown on the rating plate.  

The power supply will provide adequate power for the instrument. The user should ensure that all other auxiliary 
apparatus, drawing power from the host, does not overload the power supply. 

A damaged mains cord should be replaced by the user.  

The air receiver and controller operate on a 24v DC supply, managed by a power supply unit built into the air 
receiver body that accepts a 110/230v universal input. The power to the controller is delivered via power over 
ethernet (PoE). A relay within the air receiver assembly separately diverts the mains 110/230v supply directly to 
the compressor via the ‘power out’ port on the air receiver top plate. In order for the system to safely operate 
at either a 110 or 230 voltage, the compressor pump motor must be rated to the correct corresponding input 
voltage.  A  230v  compressor  is  supplied  with  a  Pulse  2.0  system  as  standard  but  a  110v  version  of  the  same 
compressor is also available upon request.  

3.4

 

Connections 

Interconnection  to  other  equipment  via  the  externally  accessible  ports  or  wireless  connectivity  on  the 
instrument must only be made as follows: 

Power Supply Input and compressor power output: As described in Section 3.3 

USB: A storage device can be used to export test data as per the export protocol detailed in Section 8.3.1. It is 
strongly  suggested  that  any  storage  device  connected  to  the  Pulse  Control  Unit  is  scanned  for  viruses  or, 
preferably, formatted before use. The  Pulse control software  may not  have sufficient  malware protection to 
prevent the software being altered or deleted by any malware present on an inputted USB device, requiring the 
unit to be returned to the service provider for repair. 

Ethernet: To connect from an air receiver to the controller and/or from an air receiver to an additional auxiliary 
air receiver. All described in section 7.3. 

 

Содержание BTS-Pulse 2.0

Страница 1: ...System MODEL BTS Pulse 2 0 Instruction Manual and Safety Guidelines Version 6 2 Version number 6 2 Product Pulse Air Permeability Measurement Instrument Type Customer instruction manual and safety gu...

Страница 2: ...rt Servicing and Calibration 10 5 3 Cleaning the Air Receiver unit 11 5 4 Cleaning of the touch screen 11 6 Scope of Use 12 6 1 Pulse Property Size Limitations 12 6 1 2 Conversion of 50Pa figures to 4...

Страница 3: ...istics of buildings and enclosures This manual provides factory prescribed operation and maintenance procedures for a Pulse 2 0 LPP Unit The procedures illustrated in this document are only to be perf...

Страница 4: ...further information please contact BTS Ltd 2 2 Supply All Pulse LLP Units are securely packaged in bespoke strong cardboard boxes for shipping Upon receipt please check immediately to establish whethe...

Страница 5: ...ards Do not continue to operate the equipment if you are in any doubt about it working normally or if it is damaged in any way Switch off then withdraw the mains plug and consult your service agent En...

Страница 6: ...0v supply directly to the compressor via the power out port on the air receiver top plate In order for the system to safely operate at either a 110 or 230 voltage the compressor pump motor must be rat...

Страница 7: ...roller 3 0kg Compressor 16 0kg Ancillaries Supplied 1x 3m IEC to mains plug cable 1x 2m IEC compressor power cable 1x 2m air delivery hose 1x 4m Controller CAT5e data cable System Outputs Air Leakage...

Страница 8: ...wer over Ethernet and USB ports The diagram shows the components in place Room Temperature Sensor Room Pressure Sensor User Touchscreen USB Port Power Indicator LED RJ45Power over Ethernet EIC Power o...

Страница 9: ...essor and hose supplied by BTS has been selected for its minimal maintenance requirements low charge time low noise and high durability we therefore recommend using this compressor with the Pulse unit...

Страница 10: ...e safe and efficient operation but also poor data connections can lead to missing data packets and unnecessary failed tests System airtightness test Annually Ensuring there are no leaks in your system...

Страница 11: ...ce 24 Months Software updates Software system updates issued by BTS to all Pulse customers Adding features and new functionality As issued Pressure system service The Pressure Equipment Directive PED...

Страница 12: ...ty of Pulse for a given application Due to varying levels and leakage characteristics of buildings results may not be obtainable even for properties within the following guidelines To ensure successfu...

Страница 13: ...sing the Power Law It should be noted in all cases however that the performance of a building at 4Pa does not correlate directly with its performance at 50Pa The conversion required is specific to the...

Страница 14: ...release from affecting the sensors contained within it A 4m control cable is provided to allow for this and it is advised that where possible the unit should be positioned around a corner or behind ob...

Страница 15: ...nent testing You may also wish to warn them of the noise made during testing as some occupants may find this disconcerting if they are not warned In occupied premises where pets are present it is advi...

Страница 16: ...e felt A further 1 5 second background pressure sampling during which time the system records external and internal air pressure A second 1 5 second release of air this time a lesser velocity than the...

Страница 17: ...does not span 4Pa The warning will state low pressure if the maximum of the range is below 4Pa and high pressure if the minimum of the range is above 4Pa This does not invalidate the test but means th...

Страница 18: ...Pulse equipment in hand It is very rare for an n exponent of more than 1 0 to be recorded but if it is we advise assessing the achieved pressure range perhaps repositioning the equipment e g ensuring...

Страница 19: ...s per your organisation s convention c The air receivers successfully connected to the controller should display in the table in the bottom half of the page Here you can electronically set a target ch...

Страница 20: ...appear g Property Type list of drop down options appear h Building Construction list of drop down options appear i Notes free text field for any additional notes you may wish to input Click Next 4 To...

Страница 21: ...28 5 The launch screen will appear select launch to begin the test algorithm The test will then launch showing the following messages on screen 1 Testing in 5 4 3 2 1 2 Recording Background Pressure...

Страница 22: ...export testing data in either pat or csv format depending on Pulse model and software version being used to a USB stick delete testing data re run tests or show historic results Whilst the memory cap...

Страница 23: ...will be permanently deleted 8 3 2 Rerun To save re inputting settings for a test that has been carried out previously selecting the Rerun icon next to a test will take you to the test screen with all...

Страница 24: ...allowing for greater efficiency Alter these figures by tapping on them and making changes Select Save Changes after any changes have been made to save them to system memory To discard changes and exit...

Страница 25: ...Select install and the system will automatically install the software and reboot Once rebooted return to the software screen to check that the current software version reads as you expect it to 8 6 Ta...

Страница 26: ...ugged in or no power supply via the data cable Switch on the power supply to the air receiver Check MCB of the mains circuit Disconnect and reconnect the controller data cable ensuring it is twist loc...

Страница 27: ...7 of 28 of over or under pressurisation or for air flow test data errors n coefficient and r2 Calculation error caused by operating conditions Check connections consider repositioning of the unit and...

Страница 28: ...1 01 2018 4 8 01 07 2018 5 2 01 01 2019 5 6 01 07 2019 6 01 01 2020 6 4 01 07 2020 6 8 01 01 2021 7 2 3 4 5 6 7 8 02 12 2015 01 12 2016 01 12 2017 01 12 2018 01 12 2019 30 11 2020 30 11 2021 Inaccurac...

Отзывы: