Страница 1: ...INSTALLATION MANUAL CONDITIONING ENERGY RECOVERY VENTILATOR CERV MODEL CERV 001 PARTA CERV 001 PARTB REV 0 36 01 27 2015...
Страница 2: ...Revision 0 36 01 27 2015 Page 2 CERV SYSTEM FOOTPRINT NAMEPLATE RATINGS...
Страница 3: ...pump must be used 5 An inline water trap must be effectively utilized as detailed later to prevent air from being drawn into the CERV 001 PARTA unit through the drain tubing INSTALLATION PROCEDURE 1...
Страница 4: ...the PARTA and PARTB units together rigid galvanized duct fittings should be used All ducting between the units must be insulated and sealed especially the outlet side since the air will be heated or...
Страница 5: ...nature of the system there are several ways to duct the CERV for operation See the following to determine the most applicable configuration DUCTING WITH AN EXISTING MINISPLIT FURNACE CABINET DUCTING W...
Страница 6: ...dditionally you may wish to filter the return air to remove dust or other particulates from the air when the CERV is in a recirculation mode The filter boxes that are typically supplied with the CERV...
Страница 7: ...ound at home improvement stores In colder climates it may be necessary to add additional insulation if it appears that the ducts may be showing signs of sweating FILTER BOXES The Fantech FB6 filter bo...
Страница 8: ...erflow water pan underneath the CERV such as a washing machine pan cut a hole in it and attach a fitting and drain tube to the floor drain condensate pump ELECTRICAL 1 For further electrical informati...
Страница 9: ...hite wire in the HV junction box The supply blower wires will be labeled BinN and BinH while the exhaust blower wires will be labeled BoutN and BoutH Blowers may share the same ground green 6 Run the...
Страница 10: ...luded with the heater This wire will only carry a low current 24vAC control signal therefore thermostat wire may be acceptable if the included wire is not long enough b Set the Warm Air dial pictured...
Страница 11: ...labels b Wires may be run through the same stress relief as the PARTA wiring and the wireless relay can be secured with a strip of Velcro not included c A short length of adhesive backed Hook and Loop...
Страница 12: ...001 PARTA CERV 001 PARTB Volts AC 240 Volts AC 120 Amps 2 1 Amps 2 5 Ph 1 Ph 1 Hz 60 Hz 60 Minimum Circuit Ampacity 8 75 Minimum Circuit Ampacity 2 5 Max Fuse Size Amps 15 Max Fuse Size Amps 15 Blowe...
Страница 13: ...TRAL wire white Bin H Red Connect to INDOOR SUPPLY BLOWER HOT wire black Bin N white Connect to INDOOR SUPPLY BLOWER NEUTRAL wire white Bout H Red Connect to OUTDOOR EXHAUST BLOWER HOT wire black Bout...