BÜHLMANN Quantum Blue Reader Скачать руководство пользователя страница 7

7

Quantum Blue 

®

  Reader - User Manual Version A1

Release Date: 2020-11-04

SAFETY INFORMATION

4.8 Symbols on the Quantum Blue

®

 Reader Instrument

The following symbols appear on the type plate at the rear of the Quantum Blue

®

 Reader instrument 

Symbol

Description

CE mark for Europe

In vitro 

diagnostic mark, device is intended to be used as an 

in vitro

 diagnostic device

Serial number

Legal manufacturer

Date of manufacture

Waste Electrical and Electronic Equipment (WEEE)

Catalog number

Caution - consult instructions before use

IP10

IP Classification

GTIN

Global Trade Item Number

SAFETY INFORMATION

Содержание Quantum Blue Reader

Страница 1: ...Quantum Blue Reader User Manual Version A1 Quantum Blue Reader User Manual...

Страница 2: ...elivered Content 10 6 Unpacking and Set up Procedures 10 6 1 Unpacking of the Quantum Blue Reader 10 6 2 Setup and Connection of the Quantum Blue Reader 10 6 2 1 AC Power Connection 10 7 Installation...

Страница 3: ...Security within Communication Settings 32 11 4 10 Shutdown Settings 33 12 Maintenance and cleaning 33 12 1 Cleaning 33 12 2 Maintenance 34 12 3 Device Self Check 35 13 Technical and Scientific Suppor...

Страница 4: ...Technical Assistance At B HLMANN Laboratories AG we pride ourselves on the quality and availability of our technical and scientific support Our Customer Support Department is staffed by experienced sc...

Страница 5: ...zard related e g security messages maintenance and cleaning guidelines 4 1 Proper Use The Quantum Blue Reader must be operated by personnel familiar with B HLMANN Quantum Blue assays and have the appr...

Страница 6: ...with all national state and local health and safety regulations and laws 4 2 Electrical Safety Any defects which you discover on electrical components sub assemblies must be repaired without delay Unt...

Страница 7: ...Quantum Blue Reader instrument Symbol Description CE mark for Europe In vitro diagnostic mark device is intended to be used as an in vitro diagnostic device Serial number Legal manufacturer Date of m...

Страница 8: ...e Reader User Manual Version A1 Release Date 2020 11 04 4 9 Symbols on the Package of the Reader SAFETY INFORMATION Symbol Description Transport and Storage conditions p Keep package dry j Handle pack...

Страница 9: ...chapter 4 8 Symbols on the Quantum Blue Reader Instrument 7 3 USB ports type A 8 Ethernet port RJ 45 5 FUNCTIONAL DESCRIPTION 5 1 Hardware 2 1 3 8 4 7 5 6 Figure 1 Figure 2 The drawer can be complete...

Страница 10: ...with the device Plug the power supply cable low voltage end into the connector at the rear of the device pos 5 in chapter 5 1 Hardware Plug the power supply cable mains end into a power outlet Make su...

Страница 11: ...on to a power supply Thermal printer The Quantum Blue Reader can be connected to a Dymo TM 450 label writer with large address labels 101 x 54mm via USB 7 3 Relocating the Quantum Blue Reader The Quan...

Страница 12: ...tolerance range If the measured values of the internal reference standards are outside of the tolerance range a warning message will be displayed For additional information about this warning message...

Страница 13: ...Structure Figure 5 shows the menu structure of the Quantum Blue Reader The grey shaded box indicates menus which are available for administrators only For more information on administrator settings re...

Страница 14: ...ire the reading of the barcode card When starting the measurement the Quantum Blue Reader will first run the test specific incubation time and then scan the test cassette In the Fast Track Mode see ch...

Страница 15: ...e your barcode card and press Continue when prompted by the instructions on the screen Note The reader has now loaded all method specific settings to perform the run such as test method lot ID and cal...

Страница 16: ...e screen displaying all test specific parameters e g test method product ID Lot ID expiration date incubation time setting etc If the test settings are correct press Continue to proceed to the sample...

Страница 17: ...test cassette according to the test specific instruction for use Ensure that the test cassette is placed in the correct orientation refer to the test cassette relief within the drawer Close the drawe...

Страница 18: ...the LOT ID is missing you can import the test method 3 with the correct lot ID by using the barcode card included in your test package refer to Fail Safe Mode step 2 To go one step back tap the Go Ba...

Страница 19: ...ation time of your test cassette is done via an external timer press YES or whether the incubation time should be counted down by the reader press NO Note For some tests the incubation time can t be s...

Страница 20: ...e onto the test cassette according to the test specific instruction for use Ensure that the test cassette is placed in the correct orientation refer to the test cassette relief within the drawer Close...

Страница 21: ...ic instruction for use Set an external timer manually for the test specific incubation time as indicated in the corresponding instruction for use Open the drawer and place the test cassette into the h...

Страница 22: ...specific test results 3 Swipe over the result list to scroll down the list Long press on a result tile opens a menu with additional actions Number Action 4 Select results for export or printing 5 Sele...

Страница 23: ...1 Status Press System Status to enter a menu where you can access technical information about the Quantum Blue Reader There are two options available Info Menu 1 displays IP address device name device...

Страница 24: ...tant The Quantum Blue Reader prevents importation of already installed test methods Figure 6 Figure 7 11 2 Update Tests Enter this menu to update the Quantum Blue Reader with new test methods The menu...

Страница 25: ...nces 1 which is accessible to all users Admin Area 2 which is only accessible to administrators 11 3 1 Preferences Within the menu Preferences the user can adjust the screen brightness 80 is the defau...

Страница 26: ...ctivated refer to chapter 11 4 5 User Management The folllowing settings can be changed within this menu Date Time 1 settings of the Quantum Blue Reader Manage Data 2 to delete installed test methods...

Страница 27: ...elow Delete Methods Delete Results and Delete Unsent Results submenus have a similar structure 1 2 3 4 1 2 3 4 5 By pressing the Delete Methods submenu button an overview of all installed test methods...

Страница 28: ...the server If you do not want the results to be sent to the server these results or a selection of them can be deleted under this submenu Please note that deletion of results under this sub menu only...

Страница 29: ...rated results are not linked to the programmed users 3 4 5 1 2 Two user roles are available 1 Administrator who can change settings and delete data in the Settings Admin Area menu 2 Lab user who can a...

Страница 30: ...e chapter 9 1 The Two Modes of Operations 11 4 8 Manufacturer reset An orange warning screen Figure 8 asking for confirmation to proceed will appear if you press the Manufacturer Reset button If you c...

Страница 31: ...y Alternatively a DHCP Dynamic host configuration protocol can be turned on 1 and the Quantum Blue Reader will receive its network configuration from a DHCP server 11 4 9 Communication Settings In thi...

Страница 32: ...be turned on 1 The Connect server IP address and port number need to be entered and changes need to be saved 2 By pressing Test 3 it can be tested if the connection to the Quantum Blue Connect Softwar...

Страница 33: ...ork 1 2 12 1 Cleaning In order to clean the Quantum Blue Reader housing use a damp cloth moistened with water or a mild detergent If the dirt is persistent rub the surface of the Quantum Blue Reader w...

Страница 34: ...n Figure 10C The user can now clean the internal reference material and restart the Quantum Blue Reader for another self check Steps to clean Turn on the Quantum Blue Reader Figure 10A Ensure to have...

Страница 35: ...Reader is switched on In case of self check failure either a warning message stating to clean the internal reference materials is displayed Figure11 refertochapter12 2Maintenance orawarninngmessagest...

Страница 36: ...Department at B HLMANN Laboratories AG In case you need to return the Quantum Blue Reader it must be decontaminated and free of pathogens and infectious materials in order to be handled safely in a no...

Страница 37: ...assette within 30 seconds Test already exists Err 2012 A test method with the same Product ID and Lot ID is already installed on the Quantum Blue Reader Delete existing method on device with same name...

Страница 38: ...test methods and up to 300 test results Operating conditions 15 35 C 59 95 F humidity 70 not condensing Transport Conditions 20 to 50 C Storage Conditions 15 to 40 C IP classification IP10 15 3 Softw...

Страница 39: ...equirements of the instrument External Power Supply Input 100 240 V AC 0 5 A 50 60 Hz Output 12 V DC 1 67 A 15 6 Optional Accessories External printer Dymo TM 450 Label writer Printer labels Dymo larg...

Страница 40: ...6 Particular requirements In vitro diagnostic IVD medical equipment Safety requirements for electrical equipment for measurement control and laboratory use Part 1 General requirements Safety requirem...

Страница 41: ...ct tort or otherwise B HLMANN shall not be liable for any losses caused through use of the Quantum Blue Reader its software or by analysis results generated by the customer and or supplied to third pa...

Страница 42: ...t at the time of disposal helps to conserve natural resources and ensures that the product is recycled in a manner that protects human health and the environment B HLMANN Laboratories AG accepts its r...

Страница 43: ...43 Quantum Blue Reader User Manual Version A1 Release Date 2020 11 04 17 DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY...

Страница 44: ...s reserved The information contained in this document is subject to change without notice Trademarks Trademarks and labels used in this document are property of their respective owners Copyright Infor...

Отзывы: