ELK
6 Maintenance
During maintenance, remember:
– The equipment must be maintained by a professional familiar with the safety requirements and risks.
– Only perform maintenance work described in these operating and installation instructions.
– Observe the respective safety regulations and operating specifications when performing any type of maintenance.
– Always use genuine spare parts.
DANGER
Electrical voltage
Electrocution hazard.
a) Disconnect the device from power supply.
b) Make sure that the equipment cannot be reconnected to mains unintentionally.
c) The device must be opened by trained staff only.
d) Regard correct mains voltage.
CAUTION
Hot surface
Burning hazard
Let the device cool down before maintaining.
CAUTION
High pressure
Hazard of injury due to flung off parts or oil, environmental hazard due to oil.
a) Before starting any maintenance or repair to the oil circuit, make sure that the device
is depressurized. This applies to the threaded plugs as well.
b) Avoid environmental pollution (oil spills) during cleaning or maintenance of the oil
circuit.
c) Use drip pans.
Under normal operating conditions the aggregates are maintenance free. Preventive maintenance must therefore be routinely
carried out by the operating company.
When doing so, please pay attention to:
– Tight screw fittings,
– Tightness,
– Damage to the aggregate (replace damaged parts),
– Abnormal (unusual) noise and vibration,
– Cooler matrix cleanliness. Dirt on the cooler matrix reduces the cooling capacity,
– Check warning labels for legibility and damage.
Electrical connections must be checked annually by a licensed electrician.
The external parts the motors, particularly the cooling ribs and cooling ducts as clean as possible to prevent compromising heat
release.
Please note the specified protection against dust and moisture. Pressure cleaning is only permitted if the motor has the respect-
ive protection rating.
The motors feature ball bearings sealed on both sides. The grease filling is designed to last for the life of the unit. Greasing is not
necessary.
The motor mounts may only be replaced by Bühler Technologies GmbH or a qualified specialist company.
10
Bühler Technologies GmbH
BE350034 ◦ 08/2022
Содержание 35ELK10040