9
KEYPAD
The keypad (Item 12 on page 8) is the second section of the control panel. This is used for programming and
inputting dimensions. An overview of the key functions is provided below.
ALPHA KEYS
Press keys A, B, C, D, or E for the function desired, as described in the
“Programming” section of this manual.
DIGIT KEYS
Use the digit keys to enter pipe diameters or dimensions.
ENTER
Push the ENTER button to store the numeric value entered.
BACKSPACE
Use BACKSPACE to remove the last digit keyed in before pushing the ENTER
button, if a correction is required.
SHIFT
The blank key in the top right corner of the keypad is the SHIFT key. Use this key
to access additional programming options.
ARROW KEYS
Used to jog vertical axis during auto-run program to set new torch position.
CWP-1570 CONTROL PANEL, CONT’D.
ROTATION CONTROLS
The rotation controls are located on the left portion of the control panel (Items 1-11 on page 8). Use these
controls to maneuver the electrode to the starting position, to start or interrupt the weld and to control the
rotation speed. A brief description of each item is provided below.
ROTATION SPEED
Displays reference # only
SPEED CONTROL
Controls speed of rotation. Turn right to increase; left to decrease
STOP / PAUSE
Immediately stops welding and rotation. Does not burnback or purge
START / RESUME
Starts or resumes program
RESET
Resets home or weld start position
MANUAL JOG
Manually position welding electrode for vertical and horizontal axes
CONTROL POWER
Enables / Disables power to control panel
POWER INDICATOR
When lit, indicates power ON to control panel
CIRCUIT BREAKER
Protects control box electronics
MIRROR IMAGE
Reverses rotation direction
WELD ON/OFF
ON enables weld. OFF disables weld for dry run
PROGRAMMING
FUNCTION KEYS
All programming is done using the
PENDANT CONTROL
. Use the following Alpha Keys for programming:
A: To enter dimensions.
B: To enter the time delay for puddle build-up.
C: To change Program Number in memory (numbers 0 – 99).
D: To display the dimensions of the weld.
E: To enter the number of passes (1 – 99).
Three other useful key functions are:
Shift 9: Set units, English (inch) or metric (meters)
Shift 8: Test drives & encoders
Shift E: Version number (have this information ready when calling for service)
DATA REQUIRED
1. Small diameter (nozzle size)
2. Large diameter (pipe it fits on)
3. Offset distance between centerlines
Содержание CWP-7
Страница 13: ...13 CWP 1570 WD CONTROL PANEL WIRING DIAGRAM 1 OF 3 ...
Страница 14: ...14 A B C D CWP 1570 WD CONTROL PANEL WIRING DIAGRAM 2 OF 3 ...
Страница 15: ...15 CWP 1570 WD CONTROL PANEL WIRING DIAGRAM 3 OF 3 ...