Device Requirements 

Max. Cord Length (ft) by Wire Gauge 

Amps 

Watts (120V) 

Watts (240V) 

#8 wire 

#10 wire 

#12 wire 

#14 wire 

#16 wire 

2.5 

300 

600 

NR 

1000 

600 

375 

250 

600 

1200 

NR 

500 

300 

200 

125 

7.5 

900 

1800 

NR 

350 

200 

125 

100 

10 

1200 

2400 

NR 

250 

150 

100 

50 

15 

1800 

3600 

NR 

150 

100 

65 

NR 

20 

2400 

4800 

175 

125 

75 

50 

NR 

25 

3000 

6000 

150 

100 

60 

NR 

NR 

30 

3600 

7200 

125 

65 

NR 

NR 

NR 

40 

4800 

9600 

90 

NR 

NR 

NR 

NR 

NR = Not Recommended. 

 
Figure 9 - Maximum Extension Cord Lengths by Power Requirement 

 

DC Usage 

 

                                                                                     

 

The DC outlet is only for recharging 12 Volt automotive-type batteries. Do not connect any other device to this outlet.

 

 

                                                                                     

  

Use this generator only for recharging 12 Volt batteries. NEVER attempt to jumpstart a car with this generator.

 

 

                                                                                     

 

Failing to use the correct procedure can cause a battery to explode, seriously injuring anyone nearby. Keep heat, sparks, flame and 
smoking materials away from the battery.

 

 
To connect 12 Volt batteries to the DC outlet: 
1. Connect the red charging wire to the positive terminal of the battery and the black charging wire to the negative terminal of the battery. 

2. Connect the plug end of the wire to the 12V DC outlet on this generator. 

3. Start this generator. 

4. When disconnecting, always disconnect the wires from this generator first to avoid a spark. 
 

                                                                                         

 

Storage batteries emit highly explosive hydrogen gas when charged.

 

Batteries also contain acid, which can cause severe chemical burns. 

• Do not allow open flames or cigarettes nearby for several minutes after charging a battery. 
• Always wear protective goggles and rubber gloves when charging a battery. 
 

• If battery acid gets on the skin, flush with water. 

 

• If battery acid gets in the eyes, flush with water and immediately call a physician. 

 

• If battery acid is swallowed, drink large quantities of milk and immediately call a physician. 

 

STOPPING THE GENERATOR 

 
To stop this generator: 
1. Turn off all connected electrical devices and then unplug them. 

2. Allow this generator to run for several more minutes with no electrical devices connected to help stabilize the temperature of this generator. 

3. Turn off the engine switch. 

4. If using LPG / NG, turn the LPG / NG fuel valve to the “off” position. 
 

                               

                                                          

   

Allow this generator to cool down before touching areas that become hot during operation.

 

 
 
 

Содержание GEN7500TRI

Страница 1: ...ou experience a problem or need parts call customer service at 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time A copy of the sales receipt is required IF THERE IS ANY QUESTION ABOUT A CONDITION BE...

Страница 2: ...e center For owners located more than 100 miles from an authorized service center Buffalo Corp will in its sole discretion either pay for shipping costs to and from an authorized service center provid...

Страница 3: ...2 Connect Fuel 12 Step 3 Ground The Generator 13 Subsequent Use Of This Generator 13 Step 1 Verify Oil Level 13 Step 3 Ground The Generator 14 STARTING THE GENERATOR 14 USING THE GENERATOR 15 AC Usage...

Страница 4: ...oderate injury CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage Legal Requirements Federal and or State Occup...

Страница 5: ...This generator produces powerful voltage which can result in electrocution ALWAYS ground this generator before using it See Ground the Generator section in this manual Only electrical devices should b...

Страница 6: ...in the storage and use areas Storage areas must meet national electric codes for class 1 hazardous areas Propane and Natural Gas smells like rotten eggs a skunk s spray or a dead animal IF YOU SMELL...

Страница 7: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 7...

Страница 8: ...Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 8 In addition to the previously described safety information familiarize yourself with all safety and h...

Страница 9: ...omer service DO NOT RETURN THIS GENERATOR TO THE RETAILER Item List Set of 2 DC connector wires for charging 12 Volt automotive type batteries Spark plug wrench 5 Ft Regulator Hose Kit YOU MUST USE TH...

Страница 10: ...SUPPLIED REGULATOR FOR SAFE OPERATION THIS IS NOT USED FOR NATURAL GAS ATTENTION The Air fuel Mixer is not adjustable Tampering with the governor can damage your generator and electrical devices and w...

Страница 11: ...local natural gas professional advise this information Fuel Consumptions Fuel Load Natural Gas 160 cu ft hr 160 000 BTU HR Have your local fuel supplier install a protected fuel connection at the outs...

Страница 12: ...from the package this generator contains no oil in the engine crankcase The correct quantity of oil is equal to the oil capacity of the engine crankcase and is 38 fluid oz Add the correct quantity of...

Страница 13: ...with a gas hose no less than 3 8 inside diameter no longer than 10 ft 3m and to the gas inlet fig 3 Do not use the LP regulator hose for NG If using LPG or NG be sure that the carburetor is free of ga...

Страница 14: ...tion titled Using the Generator for the First Time of this manual If not review this section now Step 1 Verify Oil Level Even though this generator is equipped with an automatic shutoff to protect it...

Страница 15: ...used first install the battery using the two included cables one red and the other black according to the following procedure 1 Attach one end of the red cable to the positive terminal on the battery...

Страница 16: ...e less than or equal to the rated wattage for the generator i e no more than 6000 for this generator This generator can run at its surge wattage capacity for only a short time Connect electrical devic...

Страница 17: ...though this Generator has an overall rated wattage of 6000 do not attempt to draw more than 20 AMPS from any set of Two receptacles of the 120 Volt outlets Draws higher than 20 Amps will damage this...

Страница 18: ...charging wire to the positive terminal of the battery and the black charging wire to the negative terminal of the battery 2 Connect the plug end of the wire to the 12V DC outlet on this generator 3 St...

Страница 19: ...ck X Clean X Fuel Filler Cap Clean X Spark Plug Check Clean X Clean X Figure 10 Recommended maintenance schedule Cleaning the Generator Always try to use this generator in a cool dry place If this gen...

Страница 20: ...the crankcase underneath the oil filler dipstick cap as illustrated in Figure 12 3 Allow all the oil to drain from this generator 4 Replace the oil drain plug and tighten with a 12 mm wrench NOTE Neve...

Страница 21: ...is Champion RN9YC STORAGE TRANSPORT PROCEDURES Never place any type of storage cover on this generator while it is still hot When transporting or storing this generator for extended time Allow generat...

Страница 22: ...is dirty Clean or replace air filter Loose wiring harness connection Turn off generator then check wiring behind control panel and at the end of generator for loose connection If wires are loose tight...

Страница 23: ...attage W 6000 Surge Wattage W 7500 Rated Voltage V 120 240 Rated Amperage 25A 25A 25A 25A at 120 V 30 A at 240 V 30 A at 120 RV Rated Frequency Hz 60 Phase Single DC Output Voltage V 12 Circuit Breake...

Страница 24: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 24 PARTS DIAGRAM...

Страница 25: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 25...

Страница 26: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 26...

Страница 27: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 27...

Страница 28: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 28...

Страница 29: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 29...

Страница 30: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 30...

Страница 31: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 31...

Страница 32: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 32...

Страница 33: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 33...

Страница 34: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 34...

Страница 35: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 35 WIRING DIAGRAM...

Страница 36: ...owner you should however be aware that Buffalo Corp may deny your warranty coverage if your power equipment engine or a part has failed due to abuse neglect improper maintenance or unapproved modific...

Страница 37: ...l not reduce the warranty obligations of Buffalo Corp 10 Add on or modified parts that are not exempted by the Air Resources Board may not be used The use of any non exempted add on or modified parts...

Отзывы: