3
UK
Storage
Always store the appliance in the cover supplied, particularly in winter.
Troubleshooting
If your BUFFALO appliance develops a fault, please check the following table before making a call to the
Helpline.
Technical Specifications
Electrical Wiring
The plug is to be connected to a suitable mains socket.
This appliance is wired as follows:
•
Live wire (coloured brown) to terminal marked L
•
Neutral wire (coloured blue) to terminal marked N
•
Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency
disconnection being required they must be readily accessible.
WARNING: Always allow the appliance to cool before placing the cover over it.
Fault
Probable Cause
Action
The appliance is not working
The appliance is not switched on Check the appliance is plugged in correctly
and switched on
Plug and lead are damaged
Call BUFFALO agent or qualified technician
Fuse in the plug has blown
Replace the plug fuse
Power supply
Check power supply
Internal wiring fault
Call BUFFALO agent or qualified technician
Heating element has expired
Call BUFFALO agent or qualified technician
Appliance leaning too far/on it’s
side
Stand appliance upright to reset the tilt
switch
Model
Voltage
Power
Current
Dimensions
h x w x d (mm)
Weight
(with table/cover)
CC037
230V 50Hz
2400W
10.4A
2000 X 635 X 635mm
15.5kg