background image

GENTRi9K 9000 Surge Watt / 7200 Running Watt Portable Tri Fuel Liquid Propane Gas & Gasoline & Natural Gas Electric Start Generator Manual  

 

                                                                      

 

Usage:

 

Misuse of this generator can damage it or shorten its life.

 

• Use this generator only for its intended purpose. 
• Operate this generator only on a dry, level surface. 

• Allow this generator to run for several minutes before connecting any electrical devices. 
• Promptly turn off any malfunctioning devices and disconnect them. 
• Do not operate an excessive number of electrical devices in excess of the wattage capacity of this generator. 
• Do not turn on electrical devices until 

after 

they are connected to this generator. 

• Turn off all connected electrical devices before stopping this generator. 
 

 

                                                                      

 

 

Flammable liquid gas under pressure. Can form explosive mixtures with air. May cause frostbite. 

In Case Of Inhalation

: Persons suffering from 

lack of oxygen should be removed to fresh air. If victim is not breathing, administer artificial respiration. If breathing is difficult, administer 

oxygen. Obtain prompt medical attention. 

In Case Of Eye Contact

: Contact with liquid or cold vapor can cause freezing of tissue. Gently flush 

eyes with lukewarm water. Obtain medical attention immediately.

 In Case Of Skin Contac

t:  Contact with liquid or cold vapor can cause 

frostbite. Immediately warm affected area with lukewarm water not to exceed 105°F (40°C). 

Fire And Explosion Hazards: 

Propane is easily 

ignited. It is heavier than air, therefore, it may collect in low areas or travel along the ground where an ignition source may be present. Pressure 
in a container can build up due to heat, and it may rupture if pressure relief devices should fail to function. 

Storage:

 Cylinders should be stored 

upright with valve protection cap in place and firmly secured to prevent falling or being knocked over. Protect cylinders from physical damage; 
do not drag, roll, slide or drop. Use a suitable hand truck for cylinder movement. Post "No Smoking or Open Flames" signs in the storage areas. 
There should be no sources of ignition. All electrical equipment should be explosion proof in the storage and use areas. Storage areas must 
meet national electric codes for class 1 hazardous areas. 
 

                                                                      

 

 

Propane smells like rotten eggs, a skunk’s spray, or a dead animal.  IF YOU SMELL GAS- NO FLAMES OR SPARKS! Immediately put out all 
smoking materials and other open flames. Do not operate lights, appliances, telephones, or cell phones.  -  Flames or sparks from these 
sources can trigger an explosion or a fire. 
 

WHAT IS CARBON MONOXIDE (CO)? 
You can’t taste or smell CO, but it is a very dangerous gas. High levels of CO can come from appliances that are not operating correctly, or from 
a venting system or chimney that becomes blocked. CO CAN BE DEADLY! High levels of CO can make you dizzy or sick. In extreme cases, 
CO can cause brain damage or death.  
Symptoms of CO poisoning include: headache, dizziness, fatigue, shortness of breath,  

and nausea. 
 
IF YOU SUSPECT CO IS  PRESENT, ACT IMMEDIATELY! 
1. If you or a family member shows physical symptoms of CO poisoning, get everyone out of the building and call 911 or your local fire 
department. 
2. If it is safe to do so, open windows to allow entry of fresh air, and turn off any appliances you suspect may be releasing CO. 

3. If no one has symptoms, but you suspect that CO is present, call your propane retailer or a qualified service technician to check CO levels 
and your propane equipment. 
 

                                                                                 

 

Usage:

 

Consult a physician(s) before using this generator if using a pacemaker. 

Electromagnetic fields in close proximity to a heart 

pacemaker could cause a pacemaker to malfunction or fail. Caution is necessary when near the engine’s recoil starter. 
 

                                                                               

 

Usage:

 

Prolonged exposure to high noise levels can be hazardous to hearing. 

Always wear ANSI-approved hearing protection when 

operating or working around the generator when it is running. 
 

                                                                               

 

Usage:

 

This generator is not intended to power sensitive electronic equipment such as TVs, DVD players, stereos, desktop 

computers or laptop computers without the use of an appropriate line conditioner and/or surge protector (both not included). 

Sensitive electronic equipment should be operated on approved inverter type generators or pure sine wave generators. For additional 
information consult the devices operation manual or call customer service  at 1-866-460-9436 Monday - Friday, 8 AM - 4 PM Central Time. 
 

Содержание GENTRi9K

Страница 1: ...change this product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT DO NOT RETURN THIS GENERATOR TO THE RETAILER If you experience a problem have questions or need parts for this product call Customer Service at 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time A copy of the sales receipt is required FOR CONSUMER USE ON...

Страница 2: ...es from an authorized service center Buffalo Corp will in its sole discretion either pay for shipping costs to and from an authorized service center provide for a service technician to come to the owner to make the warranty repair or pay for the repair to be made at a local non authorized service center The provisions of this paragraph apply only for the contiguous states excluding the states with...

Страница 3: ...equent Use Of This Generator 13 Step 1 Verify Oil Level 13 Step 3 Ground The Generator 14 STARTING THE GENERATOR 14 USING THE GENERATOR 15 AC Usage 15 DC Usage 17 STOPPING THE GENERATOR 17 MAINTENANCE CARE 18 Recommended Maintenance Schedule 18 Cleaning The Generator 18 Checking The Oil Level 18 Changing Adding Oil 19 Changing Fuel Line 19 Air Filter Maintenance 20 Spark Plug Maintenance 20 STORAG...

Страница 4: ...ch if not avoided will result in death or serious injury WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may resu...

Страница 5: ...n the fuel valve to the off position and disconnect the spark plug Powerful Voltage This generator produces powerful voltage which can result in electrocution ALWAYS ground this generator before using it See Ground the Generator section in this manual Only electrical devices should be plugged into this generator either directly or with an extension cord NEVER connect a building electrical system t...

Страница 6: ...osion proof in the storage and use areas Storage areas must meet national electric codes for class 1 hazardous areas Propane smells like rotten eggs a skunk s spray or a dead animal IF YOU SMELL GAS NO FLAMES OR SPARKS Immediately put out all smoking materials and other open flames Do not operate lights appliances telephones or cell phones Flames or sparks from these sources can trigger an explosi...

Страница 7: ...GENTRi9K 9000 Surge Watt 7200 Running Watt Portable Tri Fuel Liquid Propane Gas Gasoline Natural Gas Electric Start Generator Manual 7 ...

Страница 8: ...ning Watt Portable Tri Fuel Liquid Propane Gas Gasoline Natural Gas Electric Start Generator Manual 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generator ...

Страница 9: ...ENTRI9K Portable LP Gasoline Generator Verify that all items are included STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service DO NOT RETURN THIS GENERATOR TO THE RETAILER Item List DC connector wires for charging 12 Volt automotive type batteries Spark plug wrench 5 Ft Regulator Hose Kit YOU MUST USE THE SUPPLIED LP REGULATOR FOR SAFE OPERA...

Страница 10: ...YOU MUST USE THE SUPPLIED LP REGULATOR FOR SAFE OPERATION ATTENTION The Air fuel Mixer is not adjustable Tampering with the governor can damage your generator and electrical devices and will void your warranty To prevent electrical shock from faulty appliances the generator should be grounded Connect a length of heavy wire between the ground terminal and the ground source Consult with a qualified ...

Страница 11: ... High Detergent Motor Oil SAE10W 30 To add oil 1 Confirm that this generator is on a level surface 2 There are TWO oil filler dipsticks located on either side of the generator Unscrew either oil filler dipstick cap from the engine as illustrated in Figure 1A 3 Using a funnel add high detergent motor oil to fill the engine crankcase to the correct quantity SAE10W 30 oil is recommended for general a...

Страница 12: ... the gas inlet connection is tightly fixed and not leaking Step 2 CHOKE VALVE GRIP is at CHOKE CLOSE position The generator may be hard to start if CHOKE VALVE GRIP is at RUN OPEN position Step 3 Check if engine oil is full Step 4 AC OUTPUT no load connected Disconnect all electrical loads from the generator set before starting the engine The generator may be hard to start if a load is connected S...

Страница 13: ...this section now Step 1 Verify Oil Level Even though this generator is equipped with an automatic shutoff to protect it from damage due to low oil it is important to check the oil level in the engine crankcase before each use to ensure that there is sufficient quantity 1 Verify that this generator is on a level surface 2 There are TWO oil filler dipsticks located on either side of the generator Un...

Страница 14: ...rst install the battery using the two included cables one red and the other black according to the following procedure 1 Attach one end of the red cable to the positive terminal on the battery and the other end of the red cable to the celenoid 2 Attach one end of the black cable to the negative terminal and the other end of the black cable to the bolt on the mounting bracket frame Step 1 If using ...

Страница 15: ...Select a combination of the electrical devices that will have a total wattage less than or equal to the rated wattage for the generator i e no more than 7200 for this generator This generator can run at its surge wattage capacity for only a short time Connect electrical devices requiring a rated running wattage equal to or less than the rated wattage of this generator Never connect devices requiri...

Страница 16: ...his Portable Tri Fuel Generator GENTRI9K has an overall rated wattage of 7200 do not attempt to draw more than 20 AMPS from any set of Two receptacles of the 120 Volt outlets Draws higher than 20 Amps will damage this generator and void the warranty 3 Make sure AC Reset button is pressed in NOTE While this generator is running power is available from either the standard 120 Volt outlets or the 240...

Страница 17: ...ing wire to the positive terminal of the battery and the black charging wire to the negative terminal of the battery 2 Connect the plug end of the wire to the 12V DC outlet on this generator 3 Start this generator 4 When disconnecting always disconnect the wires from this generator first to avoid a spark Storage batteries emit highly explosive hydrogen gas when charged Batteries also contain acid ...

Страница 18: ...lean X Spark Plug Check Clean X Clean X Figure 10 Recommended maintenance schedule Cleaning the Generator Always try to use this generator in a cool dry place If this generator becomes dirty the exterior can be cleaned with a damp cloth soft brush vacuum and or pressurized air Never clean this generator with a bucket of water and or a hose as water can get inside and cause a short circuit or corro...

Страница 19: ...ed with water and or dirt 1 Place a bucket underneath this generator to catch oil as it drains 2 Using a 17 mm hex wrench unscrew the oil drain plug located on the crankcase underneath the oil filler dipstick cap See Figure 11 3 Allow all the oil to drain from this generator 4 Replace the oil drain plug and tighten with a 17 mm hex wrench NOTE Never dispose of used motor oil in the trash down a dr...

Страница 20: ...N9YC Figure 16 STORAGE TRANSPORT PROCEDURES Never place any type of storage cover on this generator while it is still hot When transporting or storing this generator for extended time Allow generator to fully cool before moving it A hot engine and exhaust system can burn you and ignite some materials Disconnect the battery used for the electric start feature of this generator first disconnecting t...

Страница 21: ...ing harness connection Turn off generator then check wiring behind control panel and at the end of generator for loose connection If wires are loose tighten the screws and or nuts Be certain the plug in connectors are pushed together all the way Engine runs but there is no electrical output Reset button s is are off Push reset button s to on Loose wiring harness connection Turn off generator then ...

Страница 22: ... Wattage W 7200 Surge Wattage W 9000 Rated Voltage V 120 240 Rated Amperage 20A 20A 20A 20A at 120 V 30 A at 240 V 30 A at 120 RV Rated Frequency Hz 60 Phase Single DC Output Voltage V 12 Circuit Breaker Amperage A 8 Engine Approvals EPA CARB Engine Model HP 15 Engine Type 4 stroke OHV single cylinder with forced air cooling system Ignition System Non contact transistor T C I Starting System Recoi...

Страница 23: ...GENTRi9K 9000 Surge Watt 7200 Running Watt Portable Tri Fuel Liquid Propane Gas Gasoline Natural Gas Electric Start Generator Manual 23 PARTS DIAGRAM ...

Страница 24: ...GENTRi9K 9000 Surge Watt 7200 Running Watt Portable Tri Fuel Liquid Propane Gas Gasoline Natural Gas Electric Start Generator Manual 24 ...

Страница 25: ...GENTRi9K 9000 Surge Watt 7200 Running Watt Portable Tri Fuel Liquid Propane Gas Gasoline Natural Gas Electric Start Generator Manual 25 ...

Страница 26: ...GENTRi9K 9000 Surge Watt 7200 Running Watt Portable Tri Fuel Liquid Propane Gas Gasoline Natural Gas Electric Start Generator Manual 26 ...

Страница 27: ...GENTRi9K 9000 Surge Watt 7200 Running Watt Portable Tri Fuel Liquid Propane Gas Gasoline Natural Gas Electric Start Generator Manual 27 ...

Страница 28: ...GENTRi9K 9000 Surge Watt 7200 Running Watt Portable Tri Fuel Liquid Propane Gas Gasoline Natural Gas Electric Start Generator Manual 28 ...

Страница 29: ...GENTRi9K 9000 Surge Watt 7200 Running Watt Portable Tri Fuel Liquid Propane Gas Gasoline Natural Gas Electric Start Generator Manual 29 ...

Страница 30: ...GENTRi9K 9000 Surge Watt 7200 Running Watt Portable Tri Fuel Liquid Propane Gas Gasoline Natural Gas Electric Start Generator Manual 30 ...

Страница 31: ...GENTRi9K 9000 Surge Watt 7200 Running Watt Portable Tri Fuel Liquid Propane Gas Gasoline Natural Gas Electric Start Generator Manual 31 ...

Страница 32: ...GENTRi9K 9000 Surge Watt 7200 Running Watt Portable Tri Fuel Liquid Propane Gas Gasoline Natural Gas Electric Start Generator Manual 32 FRAME ASSEMBLY ...

Страница 33: ...GENTRi9K 9000 Surge Watt 7200 Running Watt Portable Tri Fuel Liquid Propane Gas Gasoline Natural Gas Electric Start Generator Manual 33 WIRE DIAGRAM ...

Страница 34: ...h the generator purchase 1 Locate the wheel and axle bolt and flat washer Figure 1 2 Attach the wheel by aligning the frame with the wheel and insert the flat washer first then the axle bolt Tighten until wheel is secure 3 Install the mounting feet Figure 2 onto the front of the frame Inserting the bolts through the frame and add the mounting feet on both the left and right side NOTE To transport ...

Страница 35: ...local natural gas professional advise this information Fuel Consumptions Fuel Load Natural Gas 160 cu ft hr 160 000 BTU HR Have your local fuel supplier install a protected fuel connection at the outside operating location They should also install a lockable fuel shut off valve at the connection point An approved flexible fuel line must be installed between the engine generator set and the supply ...

Страница 36: ...ty on emissions related parts is as follows 1 Any warranted part that is not scheduled for replacement as required maintenance in your Owner s Manual is warranted for the warranty period stated above If the part fails during the period of warranty coverage the part will be repaired or replace by Buffalo Corp according to Subsection 4 below Any such part repaired or replaced under warranty will be ...

Отзывы: