Buffalo Tools GEN2000 Скачать руководство пользователя страница 17

GEN2000 Portable Gasoline Generator  

 

 

17 

STOPPING THE GENERATOR 

 
To stop this generator: 
1. Turn off all connected electrical devices and then unplug them. 

2. Allow this generator to run for several more minutes with no electrical devices connected to help stabilize the temperature of this generator. 

3. Set the engine switch to the “OFF” position. 

4. Turn the fuel valve to the “OFF” position. 
 

                               

                                                 

   

Allow this generator to cool down before touching areas that become hot during operation.

 

 

                                                                                

 

Allowing gasoline to sit in this generator's fuel tank for extended time without use can increase the difficulty in starting this generator in 
the future. Never store this generator for extended time with gasoline in the fuel tank.

 

 
 

MAINTENANCE/CARE 

 

Proper routine maintenance of this generator is essential for safe, economical, and trouble-free operation. It will help prolong the life of this generator 
as well as help reduce air pollution. Perform maintenance checks and procedures according to the schedule in Figure 7. 
 
 

                                                                                              

 

Never perform maintenance procedures while this generator is running. Allow this generator to cool before commencing any maintenance 
procedures. Keep heat, sparks and flame away.

 

 

                               

                                                               

 

Improper maintenance and/or failure to correct any problems prior to operating this generator can cause a malfunction which could cause 
death or serious injury. Always follow the inspection and maintenance recommendations and schedules in this manual.

 

 

Recommended Maintenance Schedule 

 

 

 

Each Use 

Every Month or 
Each 20 Hrs 

Every 3 Months or 
Each 50 Hrs 

Every 6 Months or 
Each 100 Hrs 

Every Year or 
Each 300 Hrs 

Engine Oil 

Check Level 

 

 

 

 

 

Replace 

 

X (first use) 

 

 

Air Filter 

Check 

 

 

 

 

 

Clean 

 

 

 

 

Spark Plug 

Check/Clean 

 

 

 

 

Fuel Tank 

Verify Gas Level 

 

 

 

 

 

Clean 

 

 

 

 

Figure 7 - Recommended maintenance schedule 

 
 

Cleaning the Generator 

 
Always try to use this generator in a cool dry place. If this generator becomes dirty, the exterior can be cleaned with a damp cloth, soft brush, 
vacuum and/or pressurized air. 
 

Never clean this generator with a bucket of water and/or a hose as water can get inside and cause a short circuit or corrosion. 
 
Never use gasoline to clean parts of this generator. 
 
 

Checking the Oil Level 

 
It is important to check the oil level in the engine crankcase before each use to ensure that there is a sufficient quantity. 

Содержание GEN2000

Страница 1: ...to change this product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT DO NOT RETURN THIS GENERATOR TO THE RETAILER If you...

Страница 2: ...t A C Outlet 1 12 Volt D C Outlet Engine Run Time 9 Hours 50 Load Low Oil Shutdown EPA Approved Noise Level 68dB 0 Load Oil Capacity 12 ounces Fuel Capacity 1 2 gallon Fuel Type Unleaded Gasoline Only...

Страница 3: ...f This Generator 13 Step 1 Verify Oil Level 13 Step 2 Verify Gas Level 13 Step 3 Ground The Generator 13 STARTING THE GENERATOR 14 USING THE GENERATOR 15 AC Usage 15 DC Usage 16 STOPPING THE GENERATOR...

Страница 4: ...me to the owner to make the warranty repair or pay for the repair to be made at a local non authorized service center The provisions of this paragraph apply only for the contiguous states excluding th...

Страница 5: ...r s electricity does not feed back into the electric utility power lines WARNING Do not use this generator to provide power for emergency medical equipment or life support devices Carbon Monoxide Gas...

Страница 6: ...p Loosen the cap slowly to relieve pressure in the fuel tank Avoid spilling fuel Do not fill the fuel tank above the upper limit line Gasoline may expand during operation Do not fill to the top of the...

Страница 7: ...GEN2000 Portable Gasoline Generator 7...

Страница 8: ...GEN2000 Portable Gasoline Generator 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generator...

Страница 9: ...s Generator Verify that all items are included STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service DO NOT RETURN THIS GENERATOR TO THE RETAILE...

Страница 10: ...Protector 12 12 Volt DC Outlet 13 Grounding Terminal 1 Fuel Tank Cap 2 Control Panel 3 Oil Access 4 Fuel Cock 5 Carburetor Choke Lever 6 Air Filter Cover 7 Recoil Starter GENERATOR COMPONENTS Observe...

Страница 11: ...GENERATOR WILL NOT START DOUBLE CHECK THAT THE OIL LEVEL IS COMPLETELY FULL AND ALMOST OVERFLOWING This generator requires engine oil to function Engine oil is a major factor affecting engine performa...

Страница 12: ...and do not fill the fuel tank to the very top 4 Securely tighten the fuel tank cap and immediately wipe up any spilled gasoline with a dry cloth Fuel Tank Capacity gallons 1 2 Fuel Type Fresh Unleaded...

Страница 13: ...87 or higher according to Step 2 Add Gasoline of the Using this Generator for the First Time section of this manual Fuel Tank Capacity gallons 1 2 Fuel Type Fresh Unleaded Gasoline Octane Rating 87 or...

Страница 14: ...hen pull briskly to start the engine Gently return the cord into the generator to avoid damage to the starter or housing Never allow the cord to snap back 7 If the engine fails to start repeat step 6...

Страница 15: ...d wattage for the generator This generator can run at its surge wattage capacity for only a short time Connect electrical devices requiring a rated running wattage equal to or less than the rated watt...

Страница 16: ...low the engine to run for several minutes after it has been started 2 Confirm that the electrical device is switched off prior to plugging it into this generator 4 Turn on the connected electrical dev...

Страница 17: ...generator is running Allow this generator to cool before commencing any maintenance procedures Keep heat sparks and flame away Improper maintenance and or failure to correct any problems prior to oper...

Страница 18: ...should be changed every 6 months or for every 100 hours of use or when the oil has become contaminated with water and or dirt To drain the oil from this generator 1 Place a bucket underneath this gen...

Страница 19: ...k plug from this generator by using the included spark plug wrench 3 Visually inspect the spark plug If it is cracked and or chipped discard and install a new spark plug A E7RTC spark plug such as NGK...

Страница 20: ...line and add gasoline conditioner 2 months to 1 year Empty the fuel tank See Emptying the Fuel Tank in the Maintenance Care section 1 year or more Empty the fuel tank See Emptying the Fuel Tank in the...

Страница 21: ...Bad connecting wires cables Try a different extension cord Bad electrical device connected to generator Disconnect device try connecting another device Generator is overloaded Reduce draw on generato...

Страница 22: ...1 Oil Seal 17 30 6 1 3 JF152FFH 01 03 Dipstick 1 4 JF152FFH 01 12 O Ring 1 5 ZJ151FEH 01 03 Cover Crankcase 2 6 GB T276 Bearing 1 7 JF152FFH 01 02 Gasket Crankcase 2 NO PART NO DESCRIPTION QTY 1 JF152...

Страница 23: ...assy 1 4 JF152FFH 01 08 Guide dowel 4 5 GB T276 1994 Bearing 1 6 QJ168QDJ 05 04 Pin 1 7 JF152FFH 01 09 Clipboard 1 8 GB T16674 1 2004 Bolt M6 12 4 9 ZJ151FEH 01 01 Plate 1 1 10 JF152FFH 01 01 Washer s...

Страница 24: ...GEN2000 Portable Gasoline Generator 24 CYLINDER HEAD ASSEMBLY...

Страница 25: ...rod bolt 2 NO PARTS NO DESCRIPTION QTY 1 JF152FFH 06 01 01 Adjustment Centrifugal 1 2 JF152FFH 06 01 03 Pin 2 3 JF152FFH 06 01 02 Block Centrifugal 2 4 QJ182QDP 06 06 Cover Push rod 1 5 QJ168QDJ 05 0...

Страница 26: ...1 2 1 JF152FFH 08 01 01 Starter cover 1 1 2 2 JF152FFH 08 01 07 Pull rope 1 1 2 3 ZJ151FEH 04 01 02B Clockwork spring 1 1 2 4 JF152FFH 08 01 01 Rotary table 1 1 2 5 JF152FFH 08 01 08 Spring return 2...

Страница 27: ...ter Assy 1 3 JF152FFH 10 01 Air Cleaner Gasket 1 4 JF156FFH 12 03 02 Oil Hose 1 5 JF168FJH 10 03 03 Clip 8 5 2 NO PARTS NO DESCRIPTION QTY 1 JF156FFH 2 09 01 Carburetor Assembly 1 2 JF156FFH 09 02 01...

Страница 28: ...3 13 QJ3200 01 04 Standard Outlet 1 14 QJ6500 02 05 DC Protector 8A 8 15 10412350001 Capacitance 12Uf 350V 1 16 QJ6000 02 02 Jacket 1 17 QJ1200 02 02A Sheath 1 18 KE2000 02 02D Cable 1 19 KE2000 02 0...

Страница 29: ...ler 1 NO PART NU DESCRIPTION QTY 1 KE2000 06 01A Frame Welding Components 1 2 GB T5789 1986 Bolt M6x10 8 3 KE2000 06 01 Fuel Tank Protecting Plate 2 4 QJ1200 06 03 Right Shockproof Mounting Feet 1 5 G...

Страница 30: ...for your failure to ensure the performance of all scheduled maintenance As the power equipment engine owner you should however be aware that Buffalo Corp may deny your warranty coverage if your power...

Страница 31: ...ed in the performance of any warranty maintenance or repairs and must be provided without charge to the owner Such use will not reduce the warranty obligations of Buffalo Corp 10 Add on or modified pa...

Страница 32: ...GEN2000 Portable Gasoline Generator 32 2015 11...

Отзывы: