Buffalo Tools GEN154 Скачать руководство пользователя страница 17

SOME NOTES ABOUT POWER CORDS 
 

Long or thin cords can require more wattage from a generator to power an electrical device. Figure 6 shows the recommended cords according to 

the power requirement of the electrical device. When using cords that exceed these specifications, allow for the electrical device to have a slightly 

higher rated wattage requirement. 
 

Device Requirements 

Max. Cord Length (ft) by Wire Gauge 

Amps 

Watts (120V) 

Watts (240V) 

#8 wire  #10 wire 

#12 wire 

#14 wire 

#16 wire 

2.5  300 

600  NR 1000 600 375 250 

600 

1200  NR 500 300 200 125 

7.5  900 

1800  NR 350 200 125 100 

10  1200 

2400  NR 250 150 100  50 

15 1800  3600 NR 

150 

100 

65 NR 

20 2400  4800 175 

125 

75 50 NR 

25 3000  6000 150 

100 

60 NR 

NR 

30  3600 

7200  125 65  NR NR NR 

40  4800 

9600  90 NR NR NR NR 

NR = Not Recommended. 

 

Figure 6 - Maximum Extension Cord Lengths by Power Requirement 

 

DC Usage 

 
                                                                                

 

The DC outlet is only for recharging 12 Volt automotive-type batteries. Do not connect any other device to this outlet. 
 
                                                                                

  

Use this generator only for recharging 12 Volt batteries. NEVER attempt to jumpstart a car with this generator. 
 

                                                                                

 

Failing to use the correct procedure can cause a battery to explode, seriously injuring anyone nearby. Keep heat, sparks, flame and 

smoking materials away from the battery. 
 

 

To connect 12 Volt batteries to the DC outlet: 
1. Connect one charging wire to the positive terminal of the battery and the other charging wire to the negative terminal of the battery. 

2. Connect the free end of the positive wire to the positive side of the outlet on this generator. 

3. Start this generator. 

4. Carefully connect the free end of the negative wire to the negative side of the outlet on this generator. 

5. When disconnecting, always disconnect the wires from this generator first to avoid a spark. 
 

                                                                                 

 

Storage batteries emit highly explosive hydrogen gas when charged. 

Batteries also contain acid, which can cause severe chemical burns. 

• Do not allow open flames or cigarettes nearby for several minutes after charging a battery. 
• Always wear protective goggles and rubber gloves when charging a battery. 

 

• If battery acid gets on the skin, flush with water. 

 

• If battery acid gets in the eyes, flush with water and immediately call a physician. 

 

• If battery acid is swallowed, drink large quantities of milk and immediately call a physician. 

 
 

                                                                                

   

Do not secure the generator with a chain or rope, which would prevent it from being moved in an emergency. 
 

 

 

GEN154   2000 Surge Watts/1500 Running Watts Portable Generator  

17  

 

Содержание GEN154

Страница 1: ...ve the right to change this product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT DO NOT RETURN THIS PRODUCT TO THE RETAI...

Страница 2: ...HV Engine Recoil Start 2 4 HP Gasoline Engine Automatic Low Oil Shutdown 1 120 Volt A C Outlet 1 12 Volt D C Outlet 1 8 Gallon Fuel Tank Engine Run Time 9 Hours 50 Load 2000 Surge Watts 1500 Running W...

Страница 3: ...e Generator 12 Subsequent Use Of This Generator 13 Step 1 Verify Oil Level 13 Step 2 Verify Gas Level 13 Step 3 Ground The Generator 13 STARTING THE GENERATOR 14 USING THE GENERATOR 15 AC Usage 15 DC...

Страница 4: ...t is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER indicates an imminently hazardous situation which...

Страница 5: ...IT DIFFICULT TO MOVE IN AN EMERGENCY Keep at least several feet of clearance on all sides to allow proper ventilation for this generator Chemicals According to the State of California the exhaust fro...

Страница 6: ...or High Temperatures This generator produces heat when in operation Temperatures near the exhaust can exceed 150 Degrees Fahrenheit 65 Degrees Celsius Do not touch hot surfaces Observe all warning pla...

Страница 7: ...GEN154 2000 Surge Watts 1500 Running Watts Portable Generator 7...

Страница 8: ...In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generator GEN154 2000 Surge Watts 1500 Running Watts Portable Generator 8...

Страница 9: ...ere are missing items call 1 888 287 6981 Monday Friday 8 AM 4 PM Central Time for customer service DO NOT RETURN THIS GENERATOR TO THE RETAILER Item List NEMA L14 30 plug for connecting 240 Volt elec...

Страница 10: ...ap 2 Control Panel 3 Grounding Terminal 4 Oil Access 5 Recoil Starter 6 Carburetor Choke Lever 7 Fuel Cock 2 3 5 6 7 8 Ignition Switch 9 DC Circuit Fuse 10 AC Circuit Fuse 11 120 Volt AC Output Socket...

Страница 11: ...ity of the engine crankcase and is 13 5 fluid oz 0 40 L for this Model GEN154 2000 Surge Watts 1500 Running Watts Portable Generator Add the correct quantity of oil before operating this generator for...

Страница 12: ...very top 4 Securely tighten the fuel tank cap and immediately wipe up any spilled gasoline with a dry cloth Model GEN154 Fuel Tank Capacity gals L 1 8 7 Model GEN154 Fuel Type Fresh Unleaded Gasoline...

Страница 13: ...aded gasoline with an octane rating of 87 or higher according to Step 2 Add Gasoline of the Using this Generator for the First Time section of this manual Model GEN154 Fuel Tank Capacity gals L 1 8 7...

Страница 14: ...ne switch to the on position 6 Slowly pull on the recoil starter handle shown in Figure 4 until a slight resistance is felt Then pull briskly to start the engine Gently return the cord into the genera...

Страница 15: ...age of the generator DO NOT connect all of the devices Select a combination of the electrical devices that will have a total wattage less than or equal to the rated wattage for the generator This gene...

Страница 16: ...as an overall rated wattage of 1100 do not attempt to draw more than 1300 Watts from the 120 Volt outlet Draws higher than 1300 Watts will damage this generator and void the warranty 3 Switch the circ...

Страница 17: ...ttery to explode seriously injuring anyone nearby Keep heat sparks flame and smoking materials away from the battery To connect 12 Volt batteries to the DC outlet 1 Connect one charging wire to the po...

Страница 18: ...erform maintenance procedures while this generator is running Allow this generator to cool before commencing any maintenance procedures Keep heat sparks and flame away Improper maintenance and or fail...

Страница 19: ...fluid oz 0 40 L To drain the oil from this generator It is necessary to drain the oil from the crankcase only if it has become contaminated with water and or dirt 1 Place a bucket underneath this gen...

Страница 20: ...g such as NGK BPR5ES is recommended 4 Measure the spark plug electrode gap with a gauge The gap should be 0 028 0 031in 0 7 0 8mm See Figure 9 5 If re using the spark plug use a wire brush to clean an...

Страница 21: ...81 Monday Friday 8 AM 4 PM Central Time Symptom Cause Solution Engine switch is set to off Set engine switch to on Fuel valve is turned to closed Turn fuel valve to open Choke is open Close the choke...

Страница 22: ...GEN154 2000 SURGE WATTS 1500 RUNNING WATTS PORTABLE GENERATOR PARTS DIAGRAM GEN154 2000 Surge Watts 1500 Running Watts Portable Generator 22...

Страница 23: ...B95 6 1 11 Statir 1 56 Bolt GB T818 M6 12 1 12 Bolt GB5789 M8 170 1 13 Rotor 4 14 Tank Absorption Bush Assy GR1000A 11 1 15 Washer GB95 8 4 16 Bolt GB T16674 M8 25 2 17 Fuel Tank Assembly GR1000A 06 0...

Страница 24: ...GEN1540809 GEN154 2000 Surge Watts 1500 Running Watts Portable Generator 24...

Отзывы: