•  Refer routine servicing to qualified biomedical technical personnel. 

•  Changes or modifications not expressly approved by Buffalo Filter could void the manufacturer’s 

warranty.

•  To avoid risk of Electric Shock, this equipment must only be connected to a supply mains with   

protective earth.

The warranty on this product is void if any of these warnings are disregarded. 

1.4.2 CAUTIONS:

•  Federal law (United States of America) restricts this device to be used by, or on the order of a physician. 

 

•  Do not block either the tubing or the filter. If either becomes occluded or significantly restricted, the 

motor/blower may overheat and cause the unit to fail.

•  Using any other filter or accessory not supplied by BUFFALO FILTER may cause damage and/

    or cause the system to be inoperable and may void the warranty.

•  Care must be exercised in the installation of hoses, adapters and suction canisters.  Failure to 

    follow the procedures outlined in this manual may result in overheating of the motor and may 

    void the unit warranty.

•  When using and accessory that will be connected to a surgical cannula, ensure that a mechanical 

means of closing the flow to the evacuator is available, such as a stopcock to prevent unwanted loss of 

pneumo gasses during the procedure or in case of system failure.

•  This device is not intended for evacuation of fluid.  If fluid is expected to be aspirated to the ViroSafe® 

Filter, fluid collection devices must be installed with the vacuum hose assembly.  Failure to install a 

fluid collection device could cause filter blockage and electrical damage. 

•  The ViroSafe® Filter should be changed according to the life of the filter.  The ViroSafe® Filter, used with 

the Turbo Auto-Sense™ Smoke Evacuation System(s), should not be used for more the time specified 

for each filter. Failure to change the filter may result in decreased efficiency and contamination of the 

electric motor, vacuum pump, and sound absorbing media within the unit.

•  Do not block either the tubing or the filter during operation. An occlusion or significant restriction 

may cause the motor to overheat and the unit to stop working. 

Содержание PlumeSafe Turbo

Страница 1: ...a registered trademark of Buffalo Filter LLC in the United States and other countries 2018 Buffalo Filter LLC All Rights Reserved 900989 REV J www buffalofilter com 1 716 835 7000 International 1 800...

Страница 2: ...of this manual is specified by the highest revision letter found on either the inside front cover or enclosed errata pages if any Manual Number 900989 Rev J PlumeSafe TURBO Auto Sense MEDICAL GENERAL...

Страница 3: ...m Controls 2 2 ViroSafe Filter Instructions 2 3 Set up and Operation 2 4 Specifications 3 0 MAINTENANCE 22 3 1 General Maintenance Information 3 2 Cleaning 3 3 Periodic Inspection 3 4 Troubleshooting...

Страница 4: ...filter whose high tech patented U S Patent 5874052 design captures particulates and micro organisms from 1 to 2 microns at an efficiency of 99 999 The third stage filtration uses the highest grade vir...

Страница 5: ...50 60 Hz 220 240 VAC 50 60 Hz 2 Type of protection against electrical shock UL 60601 1 Clause 5 1 Class I 3 Degree of protection against electric shock UL 60601 1 Clause 5 2 Type CF Applied Part 4 Deg...

Страница 6: ...tion of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their expense 13 This equipment operates in...

Страница 7: ...Otherwise patient injury may result The BUFFALO FILTER ViroSafe filters and single use accessories are completely disposable Please dispose of according to your local codes or regulations and hospita...

Страница 8: ...ned in this manual may result in overheating of the motor and may void the unit warranty When using and accessory that will be connected to a surgical cannula ensure that a mechanical means of closing...

Страница 9: ...y The ambient temperature during operation must be kept between 50 F to 104 F 10 C to 40 C The relative humidity during operation must be kept between 10 to 75 An atmospheric pressure range of 700 hPA...

Страница 10: ...EMOVE COVER REFER SERVICING TO QUALIFIED SERVICE PERSONNEL WARNING TYPE CF APPLIED PART IPX1 PROTECTION AGAINST INGRESS OF WATER AS DETAILED IN IEC 60529 ALTERNATING CURRENT PROTECTIVE EARTH GROUND EQ...

Страница 11: ...en will appear After inserting a filter a screen will flash for a few seconds to indicate filter type and original life Next the standard screen will appear which displays information regarding the un...

Страница 12: ...e than 6 hours a new filter or a filter with remaining filter life MUST be inserted into the filter basket to allow the unit s suction to turn back on When the filter s life is exhausted the LCD scree...

Страница 13: ...ur system or filter Call Buffalo Filter SETTING THE DEFAULT LANGUAGE 1 Turn the main power on without filter inserted 2 Scroll through languages using suction control arrow buttons and select a langua...

Страница 14: ...t intended for evacuation of fluid If fluid is expected to be aspirated using the ViroSafe Filter or the BUFFALO FILTER Turbo Auto Sense system fluid collection devices must be installed with the vacu...

Страница 15: ...y as to minimize potential trip hazard by users or patients 5 Activate the power unit by a Toggle the rocker switch on the rear of the unit to the ON position or b Depressing and releasing the footswi...

Страница 16: ...hes 13 75 x 8 x 17 23 Dimensions H x W x D centimeters 34 93 x 20 32 x 43 76 Weight lbs kg 13 75 6 24 Noise Level dBA MAXIMUM 58 dB Footswitch Pneumatic Standard Remote Control Activation YES optional...

Страница 17: ...5 Dimensions H x W x D centimeters 15 2 x 27 9 x 39 4 Weight lbs kg 4 3 Noise Level dBA MAXIMUM 60 dB Footswitch Pneumatic Standard Remote Control Activation YES optional Safety Features UL Classified...

Страница 18: ...ance RF Emissions CISPR 11 Group 1 The Turbo Auto Sense uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby ele...

Страница 19: ...V differential mode 2 kV common mode 1 kV differential mode 2 kV common mode Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and vol...

Страница 20: ...ixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with th...

Страница 21: ...output power of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80MHz 3 5 d P v1 80 kHz to 800 MHz 3 5 d P E1 800 kHz to 2 5 GHz 3 5 d P E1 0 01 0 12 0 12 0 23 0...

Страница 22: ...xternal or internal damage to the system 3 4 Troubleshooting the System see below Maintenance Section 3 0 PROBLEM POTENTIAL CAUSE CORRECTIVE ACTION 1 Smoke Evacuation System is ON but suction is minim...

Страница 23: ...r Turbo Auto Sense Smoke Evacuation System use it to properly return your unit If you do not have the original packing material ask Customer Service for advice on how to pack the unit for return shipm...

Страница 24: ...ilter by purchaser for the specific system giving rise to the liability Purchaser agrees to indemnify and hold Buffalo Filter harmless from and against all liabilities claims and demands of third part...

Страница 25: ...laws of New York State Using any filter not manufactured by Buffalo Filter may cause damage to the systems and will be cause for voiding the warranty JURISDICTION Purchaser hereby consents to the juri...

Страница 26: ...000 or 1 716 835 3414 fax www buffalofilter com Customer Service 800 343 2324 U S Only 1 716 835 7000 International Buffalo Filter is a registered trademark of Buffalo Filter LLC in the United States...

Отзывы: