Operator’s Manual 

 

BUFFALO FILTER

 

Smoke Evacuation Systems 

 

 PlumeSafe

 1202    

 

 Porta PlumeSafe

 603 

 

PlumeSafe

 

Whisper

602  

 

PlumeSafe

Whisper

 

TURBO

Rev G

Содержание PlumeSafe 1202

Страница 1: ...Operator s Manual BUFFALO FILTER Smoke Evacuation Systems PlumeSafe 1202 Porta PlumeSafe 603 PlumeSafe Whisper 602 PlumeSafe Whisper TURBO Rev G...

Страница 2: ...this manual has been performed using replacement parts approved by BUFFALO FILTER This warranty is void if the product is used in a manner or for purposes other than intended 2000 BUFFALO FILTER 595...

Страница 3: ...1 2 1 System Controls 2 1 2 2 ViroSafe Filter Instructions 2 2 2 3 Set up and Operation 2 3 2 4 Specifications 2 4 3 0 MAINTENANCE 3 1 3 1 General Maintenance Information 3 1 3 2 Cleaning 3 1 3 3 Peri...

Страница 4: ...BUFFALO FILTER Smoke Evacuation Systems Rev G This page intentionally left blank...

Страница 5: ...arbon especially designed for Buffalo Filter for the removal and adsorption of odors and toxic gases produced by burning tissues These harmful gases may constitute a health hazard to healthcare profes...

Страница 6: ...with a clean cloth Do not steam sterilize 6 The PlumeSafe Smoke Evacuation System s has a classification under the UL2601 1 Clause 5 5 according to the degree of safety of application in the presence...

Страница 7: ...he ViroSafe Filter fluid collection devices must be installed with the vacuum hose assembly Failure to install a fluid collection device could cause filter blockage and electrical damage WARNING DO NO...

Страница 8: ...er the tubing or the filter If either becomes occluded or significantly restricted the motor blower may overheat and cause the unit to fail Using any other filter or accessory not supplied by BUFFALO...

Страница 9: ...etween the two illuminated percentages WHISPER TURBO BUTTON The TURBO button is located just below the lower left corner of the membrane keypad on the front of the PlumeSafe Whisper TURBO system Durin...

Страница 10: ...ker or fuses 8 AMP for international systems are located on the rear or side of the system It electrically protects both the system and the operator from damage or injury If the system is overheated o...

Страница 11: ...to an appropriate grounded power outlet 3 Optional Attach either Remote Activator Switch or Footswitch plug into appropriate receptacle on rear or side of machine 4 Ensure that the evacuation tubing i...

Страница 12: ...le flow control Yes Yes Yes Yes Motor hp kW 1 0 0 75 1 25 0 93 1 25 0 93 0 33 0 25 STATIC SUCTION Inches H20 mbar 85 211 91 5 227 91 5 227 75 187 HOSES TUBING 1 4 7 8 1 1 4 1 3 8 6mm 22mm 32mm 35mm 1...

Страница 13: ...er TURBO With Pneumatic Footswitch and ViroSafe 6 Filter Optional Filters for Erbium YAG Laser Procedures ViroSafe 6 and ViroSafe 12 Filter Single or Double Port Available Standard Single Port at 7 8...

Страница 14: ...filter inlet Obvious external or internal damage to the system 3 4 Troubleshooting the System see below PROBLEM POTENTIAL CAUSE CORRECTIVE ACTION 1 Smoke Evacuation System is ON but suction is minima...

Страница 15: ...perly return your unit If you do not have the original packing material ask Customer Service for advice on how to pack the unit for return shipment Step 5 Freight for all returned goods should be prep...

Страница 16: ...P N PPSS603 PSS1202 and PSW0602 and three 3 years of the date of delivery for P N PSWTURBO and provided Buffalo Filter has been given the opportunity to inspect the system alleged to be defective and...

Страница 17: ...2004 BUFFALO FILTER 595 Commerce Drive Buffalo New York USA 14228 716 835 7000 or 716 835 3414 fax Division of Medtek Devices Inc Customer Service 800 343 2324 U S Only www buffalofilter com...