![Buell 2002 X1 Скачать руководство пользователя страница 402](http://html.mh-extra.com/html/buell/2002-x1/2002-x1_handbook_2826473402.webp)
2002 Buell X1: Electrical
7-29
HOME
Table 7-6. Battery Charging Rates/Times
BATTERY CABLE ROUTING
Positive battery cable runs from starter post to positive bat-
tery terminal. Negative battery cable runs from frame to neg-
ative battery terminal. See
Figure 7-34.
BATTERY INSTALLATION AND
CONNECTION
1.
Place the fully charged battery into the battery box, ter-
minal side forward.
CAUTION
Connect the cables to the correct battery terminals or
damage to the motorcycle electrical system will occur.
1
WARNING
1
WARNING
Always connect the positive battery cable first. If the
positive cable should contact ground with the negative
cable installed, the resulting sparks may cause a battery
explosion which could result in death or serious injury.
CAUTION
Overtightening bolts can damage battery terminals.
2.
Insert bolt through battery positive cable (red) into
threaded hole of battery positive (+) terminal. Tighten
bolt to 60-96
in-lbs
(7-11 Nm).
3.
Insert bolt through battery negative cable (black) into
threaded hole of battery negative (-) terminal. Tighten
bolt to 60-96
in-lbs
(7-11 Nm).
4.
Apply a light coat of petroleum jelly or corrosion retar-
dant material to both battery terminals.
5.
Install battery strap.
a.
Insert tab on right side of battery tray. Place battery
strap around top side of battery.
b.
Hook edge of strap into frame tab.
c.
Insert threaded shaft on strap through frame tab.
d.
Install battery strap locknut on threaded shaft.
Tighten to 40
in-lbs
(4.5 Nm).
5.
Apply light coat of petroleum jelly or corrosion-retardant
material to both battery terminals.
6.
Secure oxygen sensor connector to battery tray with
new
cable strap.
6.
Install seat. See
2.40 SEAT
.
Battery
Amp-Hour
State of Charge
3
Amp Charger
6
Amp Charger
10
Amp Charger
20
Amp Charger
Voltage Reading
% of Charge
SPORT
19
12.8 V
100%
-
-
-
-
12.6 V
75%
1.75 hours
50 minutes
30 minutes
15 minutes
12.3 V
50%
3.5 hours
1.75 hours
1 hour
30 minutes
12.0 V
25%
5 hours
2.5 hours
1.5 hours
45 minutes
11.8 V
0%
6 hours,
40 minutes
3 hours,
20 minutes
2 hours
1 hour
The figures listed above assume that the battery is charging at room temperature. If warmer than room temperature, use a slightly shorter
charging time. If colder, use a slightly longer charging time.
The use of constant current chargers to charge sealed maintenance-free batteries is not recommended. Any overcharge will cause dry-
out and premature battery failure. If a constant current charger is the only type available, do
not
exceed the charge times listed above and
do
not
continue charging the battery if it gets hot. When charging, never exceed 15 volts for more than 30 minutes.
Figure 7-34. Negative Battery Cable
Connection to Frame
7118
Содержание 2002 X1
Страница 2: ......
Страница 12: ...1 10 2002 Buell X1 Maintenance HOME NOTES ...
Страница 131: ...2 84 2002 Buell X1 Chassis HOME NOTES ...
Страница 162: ...3 30 2002 Buell X1 Engine HOME NOTES ...
Страница 194: ...3 62 2002 Buell X1 Engine HOME NOTES ...
Страница 198: ...4 2 2002 Buell X1 Fuel System HOME NOTES ...
Страница 314: ...4 118 2002 Buell X1 Fuel System HOME NOTES ...
Страница 325: ...5 10 2002 Buell X1 Electric Starter HOME NOTES ...
Страница 335: ...5 20 2002 Buell X1 Electric Starter HOME NOTES ...
Страница 436: ...APPENDICES SUBJECT PAGE NO Appendix A Tools A 1 Appendix B Metric Conversions B 1 Table Of Contents ...